Anesthesia recordkeeping: accuracy of recall with computerized and manual entry recordkeeping

被引:0
|
作者
Thomas Corey Davis
Jeffrey A. Green
Alexander Colquhoun
Brenda L. Hage
Chuck Biddle
机构
[1] Virginia Commonwealth University,Department of Nurse Anesthesia, School of Allied Health Professions
[2] Virginia Commonwealth University,Department of Anesthesiology
[3] Misercordia University,Department of Nursing, College of Health Sciences
关键词
Anesthesia recordkeeping; Computerized recordkeeping; Anesthesia information management systems (AIMS); Accuracy; Vigilance;
D O I
暂无
中图分类号
学科分类号
摘要
Anesthesia information management systems (AIMS) are rapidly gaining widespread acceptance. Aggressively promoted as an improvement to manual-entry recordkeeping systems (MERS) in the areas of accuracy, quality improvement, billing and vigilance, these systems record all patient vital signs and parameters, providing a legible hard copy and permanent electronic record. Concern exists that the practitioner may be less vigilant unless this data is recorded manually. This study’s purpose was to determine if vigilance, as measured by the ability to recall important data, is influenced by the method of recordkeeping. This study analyzed differences in the accuracy of Certified Registered Nurse Anesthetists’ (CRNAs) recall of specific patient variables during the course of an actual anesthetic case. CRNAs using AIMS were compared to CRNAs using MERS. Accuracy of recalled values of 10 patient variables was measured: highest and lowest values for heart rate, systolic blood pressure, inspiratory pressure, and end-tidal carbon dioxide levels, lowest oxygen saturation and total fluid volume. Four tertiary care facilities participated in this research; two of which used MERS, two utilized AIMS. A total of 214 subjects participated in this study; 106 in the computerized recordkeeping group, and 108 in the manual entry recordkeeping group. Demographic covariates were analyzed to ensure homogeneity between groups and facilities. No significant statistical differences were identified between the accuracy of recall among the groups. There was no difference in the accuracy of practitioners’ recall of patient variables when using computerized or manual entry recordkeeping systems, suggesting little impact on vigilance.
引用
收藏
页码:163 / 169
页数:6
相关论文
共 32 条
  • [31] AUTOMATED DATA EXTRACTION FROM AN INTEGRATED ELECTRONIC HEALTH RECORDS DATA REGISTRY YIELDS HIGHER ACCURACY THAN MANUAL ENTRY: RESULTS FROM THE REGISTRY FOR STONES OF THE KIDNEY AND URETER (RESKU)
    Zetumer, Samuel
    Tzou, David
    Ahmad, Tessnim
    Reliford-Titus, Shalonda
    Stoller, Marshall
    Chi, Thomas
    JOURNAL OF UROLOGY, 2018, 199 (04): : E681 - E681
  • [32] Accuracy of Manual Intracranial Pressure Recording Compared to a Computerized High-Resolution System: A CENTER-TBI Analysis (Mar 2023, 10.1007/s12028-023-01697-2 )
    Zoerle, Tommaso
    Birg, Tatiana
    Carbonara, Marco
    Smielewski, Peter
    Placek, Michal M. M.
    Zanier, Elisa R. R.
    akerlund, Cecilia A. I.
    Ortolano, Fabrizio
    Stocchetti, Nino
    NEUROCRITICAL CARE, 2023, 38 (03) : 833 - 834