Prediction of Peptide Retention in RP-LC

被引:1
|
作者
Yan Wang
Xue Gu
Jie Zhang
Xiang-Min Zhang
机构
[1] Fudan University,Department of Chemistry, Research Center of Proteome
来源
Chromatographia | 2005年 / 62卷
关键词
Column liquid chromatography; 2D-LC-ESI-MS-MS; Retention; Small peptides;
D O I
暂无
中图分类号
学科分类号
摘要
The retention of small peptides can be predicted by summing the hydrophobic contribution to retention of each amino acid of peptides. But the retention time of peptides larger than 10–15 residues are less than that predicted by summing the retention coefficients of each constitutive residue. A new prediction model, considering the effects of the peptide length and contact area of each amino acid with the stationary phase for larger peptides was proposed. The model was validated by 136 peptides identified by nano-flow 2-D-LC-ESI-MS-MS platform and other retention data observed from literature. The high degree of correlation between the observed and predicted retention time by using the new model is not only good evidence for the accuracy of our predictive method, but supports the supposition that the peptide length and contact area of each amino acid with stationary phase are important factors affecting peptide retention time for larger peptide. In addition it is found that the range of peptide length is wider, the accuracy of prediction is better. The ratio coefficient of surface area of non-polar, polar and charged amino residues contacting with the stationary phase were all calculated to be less than one.
引用
收藏
页码:385 / 392
页数:7
相关论文
共 50 条
  • [21] Sample conditions to avoid pH distortion in RP-LC
    Samuelsson, Jorgen
    Forssen, Patrik
    Fornstedt, Torgny
    JOURNAL OF SEPARATION SCIENCE, 2013, 36 (23) : 3769 - 3775
  • [22] RP-LC Determination of Residual Monomers in Polycarboxylate Superplasticizers
    Lei, Jiaheng
    Du, Xiaodi
    Zhang, Anfu
    Wu, Hui
    CHROMATOGRAPHIA, 2011, 73 (11-12) : 1131 - 1136
  • [23] RP-LC Determination of Residual Monomers in Polycarboxylate Superplasticizers
    Jiaheng Lei
    Xiaodi Du
    Anfu Zhang
    Hui Wu
    Chromatographia, 2011, 73 : 1131 - 1136
  • [24] Simultaneous RP-LC determination of additives in soft drinks
    Dossi, N.
    Toniolo, R.
    Susmel, S.
    Pizzariello, A.
    Bontempelli, G.
    CHROMATOGRAPHIA, 2006, 63 (11-12) : 557 - 562
  • [25] Simultaneous RP-LC Determination of Additives in Soft Drinks
    N. Dossi
    R. Toniolo
    S. Susmel
    A. Pizzariello
    G. Bontempelli
    Chromatographia, 2006, 63 : 557 - 562
  • [26] RP-LC determination of oleane derivatives in Terminalia arjuna
    Singh, DV
    Verma, RK
    Singh, SC
    Gupta, MM
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 28 (3-4) : 447 - 452
  • [27] Effect of large volume injection of hydrophobic solvents on the retention of less hydrophobic pharmaceutical solutes in RP-LC
    Udrescu, Stefan
    Medvedovici, Andrei
    David, Victor
    JOURNAL OF SEPARATION SCIENCE, 2008, 31 (16-17) : 2939 - 2945
  • [28] RP-LC analysis and hydrolytic degradation profile of racecadotril
    Basniwal, Pawan K.
    Srivastava, Prabhat K.
    Jain, Surendra K.
    Jain, Deepti
    CHROMATOGRAPHIA, 2008, 68 (7-8) : 641 - 647
  • [29] RP-LC Analysis and Hydrolytic Degradation Profile of Racecadotril
    Pawan K. Basniwal
    Prabhat K. Srivastava
    Surendra K. Jain
    Deepti Jain
    Chromatographia, 2008, 68 : 641 - 647
  • [30] Voltammetric and RP-LC assay for determination of benidipine HCl
    Karadas, Nurgul
    Sanli, Senem
    Gumustas, Mehmet
    Ozkan, Sibel A.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 66 : 116 - 125