Stent underexpansion is associated with high wall shear stress: a biomechanical analysis of the shear stent study

被引:0
|
作者
Sonali Kumar
David Molony
Sameer Khawaja
Kaylyn Crawford
Elizabeth W. Thompson
Olivia Hung
Imran Shah
Jessica Navas-Simbana
Arlen Ho
Arnav Kumar
Yi-An Ko
Hossein Hosseini
Adrien Lefieux
Joo Myung Lee
Joo-Yong Hahn
Shao-Liang Chen
Hiromasa Otake
Takashi Akasaka
Eun-Seok Shin
Bon-Kwon Koo
Goran Stankovic
Dejan Milasinovic
Chang-Wook Nam
Ki-Bum Won
Javier Escaned
Andrejs Erglis
Yoshinobu Murasato
Alessandro Veneziani
Habib Samady
机构
[1] Emory University School of Medicine,Division of Cardiology, Department of Medicine
[2] Georgia Heart Institute,Department of Mathematics and Computer Science
[3] Northeast Georgia Health System,Division of Cardiology, Department of Internal Medicine, Heart Vascular Stroke Institute
[4] Emory University,Nanjing First Hospital
[5] Samsung Medical Center,Division of Cardiovascular Medicine, Department of Internal Medicine
[6] Sungkyunkwan University School of Medicine,Department of Cardiovascular Medicine
[7] Nanjing Medical University,Department of Cardiology
[8] Kobe University Graduate School of Medicine,Department of Internal Medicine and Cardiovascular Center
[9] Wakayama Medical University,Department of Cardiology
[10] Ulsan Medical Center,Department of Medicine, Dongsan Medical Center
[11] Seoul National University Hospital,Department of Cardiology
[12] University Clinical Center of Serbia,Pauls Stradins Clinical University Hospital
[13] Keimyung University,Department of Cardiology and Clinical Research Center
[14] Hospital Clínico San Carlos Madrid,undefined
[15] University of Latvia,undefined
[16] National Hospital Organization Kyushu Medical Center,undefined
关键词
Intravascular ultrasound; Underexpansion; Wall shear stress; Percutaneous coronary intervention;
D O I
暂无
中图分类号
学科分类号
摘要
Coronary stent underexpansion is associated with restenosis and stent thrombosis. In clinical studies of atherosclerosis, high wall shear stress (WSS) has been associated with activation of prothrombotic pathways, upregulation of matrix metalloproteinases, and future myocardial infarction. We hypothesized that stent underexpansion is predictive of high WSS. WSS distribution was investigated in patients enrolled in the prospective randomized controlled study of angulated coronary arteries randomized to undergo percutaneous coronary intervention with R-ZES or X-EES. WSS was calculated from 3D reconstructions of arteries from intravascular ultrasound (IVUS) and angiography using computational fluid dynamics. A logistic regression model investigated the relationship between WSS and underexpansion and the relationship between underexpansion and stent platform. Mean age was 63±11, 78% were male, 35% had diabetes, mean pre-stent angulation was 36.7°±14.7°. Underexpansion was assessed in 83 patients (6,181 IVUS frames). Frames with stent underexpansion were significantly more likely to exhibit high WSS (> 2.5 Pa) compared to those without underexpansion with an OR of 2.197 (95% CI = [1.233–3.913], p = 0.008). There was no significant association between underexpansion and low WSS (< 1.0 Pa) and no significant differences in underexpansion between R-ZES and X-EES. In the Shear Stent randomized controlled study, underexpanded IVUS frames were more than twice as likely to be associated with high WSS than frames without underexpansion.
引用
收藏
页码:1375 / 1382
页数:7
相关论文
共 50 条
  • [31] Serial stent healing analysis of bioresorbable stent implanted in coronary bifurcations with optical coherence tomography: correlation with baseline shear stress
    Chu, Miao
    Li, Yingguang
    Holck, Emil
    Zhang, Su
    Dijkstra, Jouke
    Holm, Niels
    Tu, Shengxian
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (13) : B110 - B110
  • [32] HIGH WALL SHEAR STRESS AND POSITIVE WALL SHEAR STRESS GRADIENT TRIGGER THE INITIATION OF INTRACRANIAL ANEURYSMS
    Metaxa, Eleni
    Tremmel, Markus
    Xiang, Jianping
    Kolega, John
    Mandelbaum, Max
    Siddiqui, Adnan
    Mocco, J.
    Meng, Hui
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2009, PT A AND B, 2009, : 523 - 524
  • [33] Hemodynamic Induction of Intracranial Aneurysm by High Wall Shear Stress and Positive Wall Shear Stress Gradient
    Metaxa, Eleni
    Tremmel, Markus
    Gao, Ling
    Xiao, Jianping
    Mandelbaum, Max
    Swartz, Daniel D.
    Mocco, J.
    Siddiqui, Adnan
    Kolega, John
    Meng, Hui
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2009, 29 (07) : E84 - E84
  • [34] A COMPARISON OF POST-STENTING WALL SHEAR STESS BETWEEN XIENCE AND RESOLUTE: INTERIM ANALYSIS FROM THE SHEAR-STENT TRIAL
    Molony, David
    Lefieux, Adrien
    Crawford, Kaylyn
    Shah, Imran
    Khawaja, Sameer
    Dunn, Ryan
    Navas-Simbana, Jessica
    Stankovic, Goran
    Milasinovic, Dejan
    Koo, Bon Kwon
    Otake, Hiromasa
    Akasaka, Takashi
    Escaned, Javier
    Erglis, Andrejs
    Murasato, Yoshinobu
    Won, Ki-Bum
    Shin, Eun Seok
    Chen, Shaoliang S. R.
    Nam, Chang-Wook
    Lee, Joo Myung
    Veneziani, Alessandro
    Samady, Habib
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (09) : 828 - 828
  • [35] WALL SHEAR STRESS VERSUS WALLTENSILE STRESS: TWO IMPORTANT BIOMECHANICAL METRICS
    Gleason, Thomas G.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2020, 159 (03): : E157 - E158
  • [36] Hemodynamic Analysis of New Version Mirage Bioresorbable Scaffold and Metallic Ultimaster Stent: A New Era Begins With Shear Stress Analysis in Stent Assessment
    Tenekecioglu, Erhan
    Torii, Ryo
    Katagiri, Yuki
    Van Geuns, Robert-Jan
    Pekkan, Kerem
    Bourantas, Christos
    Onuma, Yoshinobu
    Serruys, Patrick
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 74 (13) : B171 - B171
  • [37] Hemodynamic Analysis of New Version Mirage Bioresorbable Scaffold and Metallic Ultimaster Stent: A New Era Begins With Shear Stress Analysis in Stent Assessment
    Tenekecioglu, Erhan
    Torii, Ryo
    Su, Solomon
    Onuma, Yoshinobu
    Bourantas, Christos V.
    Serruys, Patrick W.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (15) : S15 - S17
  • [38] Role of shear stress in atherosclerosis and restenosis after coronary stent implantation
    Mongrain, R
    Rodés-Cabau, J
    REVISTA ESPANOLA DE CARDIOLOGIA, 2006, 59 (01): : 1 - 4
  • [39] Endothelial Shear Stress and Vascular Remodeling in Bioresorbable Scaffold and Metallic Stent
    Tenekecioglu, Erhan
    Katagiri, Yuki
    Takahashi, Kuniaki
    Kitslaar, Pieter
    Dijkstra, Jouke
    Reiber, Johan
    Bourantas, Christos
    Gijsen, Frank
    Onuma, Yoshinobu
    Pekkan, Kerem
    Van Geuns, Robert-Jan
    Torii, Ryo
    Serruys, Patrick
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 74 (13) : B169 - B169
  • [40] Endothelial shear stress and vascular remodeling in bioresorbable scaffold and metallic stent
    Tenekecioglu, Erhan
    Katagiri, Yuki
    Takahashi, Kuniaki
    Tomaniak, Mariusz
    Dudek, Dariusz
    Cequier, Angel
    Carrie, Didier
    Iniguez, Andres
    van der Schaaf, Rinse Johannes
    Dominici, Marcello
    van Boven, Ad J.
    Helqvist, Steffen
    Sabate, Manel
    Baumbach, Andreas
    Piek, Jan J.
    Wykrzykowska, Joanna J.
    Kitslaar, Pieter
    Dijkstra, Jouke
    Reiber, Johan H. C.
    Chevalier, Bernard
    Ural, Dilek
    Pekkan, Kerem
    Bourantas, Christos V.
    Gijsen, Frank
    Onuma, Yoshinobu
    Torii, Ryo
    Serruys, Patrick W.
    ATHEROSCLEROSIS, 2020, 312 : 79 - 89