Two-dimensional on-line detection of brominated and iodinated volatile organic compounds by ECD and ICP-MS after GC separation

被引:0
|
作者
A. Schwarz
K. Heumann
机构
[1] Institute of Inorganic Chemistry and Analytical Chemistry,
[2] Johannes Gutenberg-University,undefined
来源
关键词
Brominated and iodinated volatile organic compounds Gas chromatography Two-dimensional detection Inductively coupled plasma mass spectrometry Electron capture detector;
D O I
暂无
中图分类号
学科分类号
摘要
Inductively coupled plasma–mass spectrometry (ICP-MS) was coupled to a gas chromatographic (GC) system with electron capture detector (ECD), which enables relatively easy characterization and quantification of brominated and iodinated (halogenated) volatile organic compounds (HVOCs) in aquatic and air samples. The GC-ECD system is connected in series with an ICP-MS by a directly heated transfer line and an outlet port-hole for elimination of the ECD make-up gas during ignition of the plasma. The hyphenated GC-ECD/ICP-MS system provides high selectivity and sensitivity for monitoring individual HVOCs under fast chromatographic conditions. The ECD is most sensitive for the detection of chlorinated and brominated but the ICP-MS for iodinated compounds. The greatest advantage of the use of an ICP-MS is its element-specific detection, which allows clear identification of compounds in most cases. The absolute detection limits for ICP-MS are 0.5 pg for iodinated, 10 pg for brominated, and 50 pg for chlorinated HVOCs with the additional advantage that calibration is almost independent on different compounds of the same halogen. In contrast to that detection limits for ECD vary for the different halogenated compounds and lie in the range of 0.03–11 pg. The two-dimensional GC-ECD/ICP-MS instrumentation is compared with electron impact mass spectrometry (EI-MS) and microwave induced plasma atomic emission detection (MIP-AED). Even if EI-MS has additional power in identifying unknown peaks by its scan mode, the detection limits are much higher compared with GC-ECD/ICP-MS, whereas the selective ion monitoring mode (SIM) reaches similar detection limits. The MIP-AED detection limits are at the same level as EI-MS in the scan mode.
引用
收藏
页码:212 / 219
页数:7
相关论文
共 41 条
  • [11] Measurements of Volatile Organic Compounds (VOC) During POPCORN 1994: Applying a New On-Line GC–MS-Technique
    Arno Wedel
    Klaus-Peter Müller
    Monika Ratte
    Jochen Rudolph
    Journal of Atmospheric Chemistry, 1998, 31 : 73 - 103
  • [12] Measurements of volatile organic compounds (VOC) during POPCORN 1994:: Applying a new on-line GC-MS-technique
    Wedel, A
    Müller, KP
    Ratte, M
    Rudolph, J
    JOURNAL OF ATMOSPHERIC CHEMISTRY, 1998, 31 (1-2) : 73 - 103
  • [13] Analysis for selenium speciation in selenized yeast extracts by two-dimensional liquid chromatography with ICP-MS and electrospray MS-MS detection
    McSheehy, S
    Pohl, P
    Szpunar, J
    Potin-Gautier, M
    Lobinski, R
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (01) : 68 - 73
  • [14] Parallel on-line detection of a methylbismuth species by hyphenated GC/EI-MS/ICP-MS technique as evidence for bismuth methylation by human hepatic cells
    Hollmann, Markus
    Boertz, Jens
    Dopp, Elke
    Hippler, Joerg
    Hirner, Alfred Vitalis
    METALLOMICS, 2010, 2 (01) : 52 - 56
  • [15] Two-Dimensional Description of Absorption in Humans after Dermal Exposure to Volatile Organic Compounds
    Simon, Laurent
    Ospina, Juan
    CHEMICAL ENGINEERING COMMUNICATIONS, 2017, 204 (06) : 698 - 704
  • [16] On-line LC-GC and comprehensive two-dimensional LCxGC-ToF MS for the analysis of complex samples
    Janssen, HG
    de Koning, S
    Brinkman, UAT
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (08) : 1944 - 1947
  • [17] On-line LC-GC and comprehensive two-dimensional LCxGC-ToF MS for the analysis of complex samples
    Hans-Gerd Janssen
    Sjaak de Koning
    Udo A. Th. Brinkman
    Analytical and Bioanalytical Chemistry, 2004, 378 : 1944 - 1947
  • [18] On-line fast column switching SEC x IC separation combined with ICP-MS detection for mapping metallodrug-biomolecule interaction
    Hann, S.
    Falta, T.
    Boeck, K.
    Sulyok, M.
    Koellensperger, G.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (06) : 861 - 866
  • [19] Determination of Trace Rare Earth Elements by ICP-MS after On-line Column Preconcentration and Separation with Single-Wall Carbon Nanotubes
    Chen, Shizhong
    Liu, Cheng
    Lu, Dengbo
    Zhu, Li
    ATOMIC SPECTROSCOPY, 2009, 30 (01) : 20 - 25
  • [20] Influence of Respiratory Manoeuvres on the On-Line Detection of Volatile Organic Compounds (VOCs) in Exhaled Breath by PTR-MS and SIFT-MS.
    Boshier, P.
    Priest, O.
    Hanna, G.
    Marczin, N.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2009, 179