A comparison of the diagnostic performance of systematic versus ultrasound-guided biopsies of prostate cancer

被引:0
|
作者
Stijn W. T. P. J. Heijmink
Hilco van Moerkerk
Lambertus A. L. M. Kiemeney
J. Alfred Witjes
Ferdinand Frauscher
Jelle O. Barentsz
机构
[1] Radboud University Nijmegen Medical Centre,Department of Radiology
[2] Radboud University Nijmegen Medical Centre,Department of Urology
[3] Radboud University Nijmegen Medical Centre,Department of Epidemiology and Biostatistics
[4] Medical University Innsbruck,Department of Radiology II
来源
European Radiology | 2006年 / 16卷
关键词
Prostate neoplasms; Prostate ultrasound; Prostate biopsy; Diagnostic radiology; Contrast media; Review;
D O I
暂无
中图分类号
学科分类号
摘要
Transrectal ultrasound (TRUS) is an important tool for urologists and radiologists in the detection of prostate cancer. Various TRUS-guided biopsy techniques are applied in clinical practice. Frequently, only the detection rates achieved with these methods are compared. Other diagnostic performance parameters, particularly the specificity and negative predictive value, are seldom compared. After extensive assessment of the available literature, this review describes the methods of TRUS-guided biopsy for prostate cancer detection. A distinction was made between systematic biopsies and biopsies that target a perceived (hypoechoic or Doppler-enhancing) lesion on imaging. Subsequently, the diagnostic performance (sensitivity, specificity, positive and negative predictive values, accuracies) was compared between these techniques. Imaging-guided biopsy showed better diagnostic performance than systematic biopsy with higher sensitivity. The combinations of sensitivity and specificity were highest for colour Doppler and contrast-enhanced targeted biopsy. Studies targeting hypoechoic lesions had relatively high sensitivity, but specificity was low. Presently however, with widespread prostate-specific antigen screening, fewer prostate cancers are hypoechoic, and the value of targeting hypoechoic lesions has diminished. Performing colour or contrast-enhanced Doppler biopsy or adding these techniques to systematic biopsies improves diagnostic performance, particularly by increasing sensitivity.
引用
收藏
页码:927 / 938
页数:11
相关论文
共 50 条
  • [41] Commentary RE: The Sextant Protocol for Ultrasound-Guided Core Biopsies of the Prostate Underestimates the Presence of Cancer
    Holmberg, Lars
    Norberg, Mona
    UROLOGY, 2020, 145 : 327 - 328
  • [42] Documenting the location of systematic transrectal ultrasound-guided prostate biopsies: correlation with multi-parametric MRI
    Turkbey, Baris
    Xu, Sheng
    Kruecker, Jochen
    Locklin, Julia
    Pang, Yuxi
    Shah, Vijay
    Bernardo, Marcelino
    Baccala, Angelo
    Rastinehad, Ardeshir
    Benjamin, Compton
    Merino, Maria J.
    Wood, Bradford J.
    Choyke, Peter L.
    Pinto, Peter A.
    CANCER IMAGING, 2011, 11 (01): : 31 - 36
  • [43] Diagnostic yield and safety of ultrasound-guided percutaneous testicular biopsies in children
    Minhas, Kishore
    Roebuck, Derek J.
    Sebire, Neil
    Cho, Alexander
    Patel, Premal A.
    PEDIATRIC RADIOLOGY, 2023, 53 (09) : 1903 - 1910
  • [44] DiaPat urine test for prostate cancer. Predictive value for results of transrectal ultrasound-guided prostate biopsies
    Oberpenning, F.
    von Knobloch, R.
    Sprute, W.
    Roth, S.
    Rathert, M.
    Bierer, S.
    Gerss, J.
    Semjonow, A.
    UROLOGE, 2008, 47 (06): : 735 - 739
  • [45] Beyond transrectal ultrasound-guided prostate biopsies: available techniques and approaches
    Warlick, Christopher
    Futterer, Jurgen
    Maruf, Mahir
    George, Arvin K.
    Rastinehad, Ardeshir R.
    Pinto, Peter A.
    Bosaily, Ahmed El-Shater
    Villers, Arnauld
    Moore, Caroline M.
    Mendhiratta, Neil
    Taneja, Samir S.
    Ukimura, Osamu
    Konety, Badrinath R.
    WORLD JOURNAL OF UROLOGY, 2019, 37 (03) : 419 - 427
  • [46] Low accuracy of routine ultrasound-guided systematic 12-core biopsies in prostate tumor mapping
    Belas, Olivier
    Hupertan, Vincent
    Comperat, Eva
    Renard-Penna, Raphaele
    Mozer, Pierre
    Bitker, Marc-Olivier
    Roupret, Morgan
    CANADIAN JOURNAL OF UROLOGY, 2012, 19 (04) : 6366 - 6372
  • [47] Diagnostic yield and safety of ultrasound-guided bowel mass biopsies in children
    Minhas, Kishore
    Roebuck, Derek J.
    Barnacle, Alex
    De Coppi, Paolo
    Sebire, Neil
    Patel, Premal A.
    PEDIATRIC RADIOLOGY, 2019, 49 (13) : 1809 - 1815
  • [48] Diagnostic yield and safety of ultrasound-guided percutaneous testicular biopsies in children
    Kishore Minhas
    Derek J. Roebuck
    Neil Sebire
    Alexander Cho
    Premal A. Patel
    Pediatric Radiology, 2023, 53 : 1903 - 1910
  • [49] Diagnostic yield and safety of ultrasound-guided bowel mass biopsies in children
    Kishore Minhas
    Derek J. Roebuck
    Alex Barnacle
    Paolo De Coppi
    Neil Sebire
    Premal A. Patel
    Pediatric Radiology, 2019, 49 : 1809 - 1815
  • [50] RANDOM SYSTEMATIC VERSUS DIRECTED ULTRASOUND GUIDED TRANS-RECTAL CORE BIOPSIES OF THE PROSTATE
    HODGE, KK
    MCNEAL, JE
    TERRIS, MK
    STAMEY, TA
    JOURNAL OF UROLOGY, 1989, 142 (01): : 71 - 75