Influence of donor lamella thickness on visual acuity after Descemet's stripping automated endothelial keratoplasty (DSAEK) [Einfluss der Spenderlamellendicke auf die Sehschärfe nach "Descemet's stripping automated endothelial keratoplasty" (DSAEK)]

被引:0
|
作者
Maier A.-K.B. [1 ]
Gundlach E. [1 ]
Klamann M.K.J. [1 ]
Gonnermann J. [1 ]
Bertelmann E. [1 ]
Joussen A.M. [1 ]
Torun N. [1 ]
Rieck P.W. [2 ]
机构
[1] Klinik für Augenheilkunde, Charité-Universitätsmedizin Berlin, 13353 Berlin, Campus Virchow-Klinikum Berlin
[2] Augenklinik Berlin-Marzahn, Berlin
来源
Der Ophthalmologe | 2014年 / 111卷 / 2期
关键词
Descemet's stripping automated endothelial keratoplasty; Endothelial cell loss; Flap thickness; Preparation technique; Visual acuity;
D O I
10.1007/s00347-013-2795-0
中图分类号
学科分类号
摘要
Background: The aim of this study was to evaluate the effect of donor lamella thickness on postoperative visual acuity after Descemet's stripping automated endothelial keratoplasty (DSAEK). Materials and methods: A retrospective analysis of 65 eyes from 61 patients who underwent DSAEK surgery in cases of Fuchs' corneal dystrophy or bullous keratopathy between 2008 and 2011 was performed. The thickness of donor lamella was measured intraoperatively by ultrasonic pachymetry and postoperatively by anterior segment optical coherence tomography (OCT) and correlated to the visual acuity and number of endothelial cells. Results: The donor lamella thickness measured intraoperatively and postoperatively correlated significantly with each other (r = 0.874, p < 0.001). A significant correlation was found between postoperative corneal lamella thickness measured by anterior segment OCT and visual acuity (r = 0.273, p = 0.028) but not between intraoperative donor lamella thickness measured by ultrasonic pachymetry and visual acuity (r = 0.241, p = 0.103). The postoperative endothelial cell number did not show a correlation with either the intraoperatively or the postoperatively measured donor lamella thickness (r = - 0.059, p = 0.731, r = 0.024, p = 0.869, respectively). Conclusions: Corneal lamella thickness < 120 μm was found to be correlated with a better visual outcome than in cases of thicker corneas > 120 μm. Despite greater difficulty in corneal transplant technique in cases of thinner lamella no increased damage of corneal endothelium was shown. Therefore, DSAEK with corneal lamella thickness < 120 μm is an interesting therapeutic alternative to DMEK. © 2013 Springer-Verlag Berlin Heidelberg.
引用
收藏
页码:128 / 134
页数:6
相关论文
共 50 条
  • [21] Descemet's membrane endothelial keratoplasty (DMEK) versus Descemet's stripping automated endothelial keratoplasty (DSAEK) for corneal endothelial failure (Review)
    Stuart, Alastair J.
    Romano, Vito
    Virgili, Gianni
    Shortt, Alex J.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2018, (06):
  • [22] Influence of corneal thickness on intraocular pressure measurements following Descemet's stripping automated endothelial keratoplasty (DSAEK)
    Klamann, M. K. J.
    Maier, A. -K. B.
    Gonnermann, J.
    Torun, N.
    Ruokonen, P. C.
    OPHTHALMOLOGE, 2012, 109 (11): : 1093 - 1097
  • [23] Visual acuity, refractive error, and endothelial cell density six months after descemet stripping and automated endothelial keratoplasty (DSAEK)
    Koenig, Steven B.
    Covert, Douglas J.
    Dupps, William J., Jr.
    Meisler, David M.
    CORNEA, 2007, 26 (06) : 670 - 674
  • [24] Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK) and Glaucoma: A Retrospective Review of Treatment Outcomes
    Floyd, M. S.
    Sutphin, J. E., Jr.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [25] Descemet's Stripping Automated Endothelial Keratoplasty
    Bronner, Aaron
    OPTOMETRY AND VISION SCIENCE, 2008, 85 (09) : 808 - 813
  • [26] Descemet's Stripping Automated Endothelial Keratoplasty
    Chaurasia, Sunita
    Ramappa, Muralidhar
    Rao, Harsha Laxmana
    Bansal, Piyush
    OPHTHALMOLOGY, 2012, 119 (07) : 1498 - 1499
  • [27] Histopathological findings of failed grafts following Descemet's stripping automated endothelial keratoplasty (DSAEK)
    Alkatan, Hind
    Al-Rajhi, Ali
    Al-Shehri, Ali
    Khairi, Ali
    SAUDI JOURNAL OF OPHTHALMOLOGY, 2012, 26 (01) : 79 - 85
  • [28] Mediators of Visual Acuity in Descemet Membrane Endothelial Keratoplasty and Ultrathin Descemet Stripping Automated Endothelial Keratoplasty
    Lin, Charles C.
    Chamberlain, Winston D.
    Kakigi, Caitlin
    Arnold, Benjamin F.
    Rose-Nussbaumer, Jennifer
    CORNEA, 2024, 43 (07) : 853 - 859
  • [29] Effect of donor graft characteristics on clinical outcomes in Descemet stripping automated endothelial keratoplasty (DSAEK)
    Yin, G. Ho Wang
    Sampo, M.
    Soare, S.
    Hoffart, L.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2017, 40 (01): : 36 - 43
  • [30] Einfluss der Hornhautdicke nach posteriorer lamellärer Keratoplastik (DSAEK) auf die Messung des AugeninnendrucksInfluence of corneal thickness on intraocular pressure measurements following Descemet’s stripping automated endothelial keratoplasty (DSAEK)
    M.K.J. Klamann
    A.-K.B. Maier
    J. Gonnermann
    N. Torun
    P.C. Ruokonen
    Der Ophthalmologe, 2012, 109 : 1093 - 1097