Influence of donor lamella thickness on visual acuity after Descemet's stripping automated endothelial keratoplasty (DSAEK) [Einfluss der Spenderlamellendicke auf die Sehschärfe nach "Descemet's stripping automated endothelial keratoplasty" (DSAEK)]

被引:0
|
作者
Maier A.-K.B. [1 ]
Gundlach E. [1 ]
Klamann M.K.J. [1 ]
Gonnermann J. [1 ]
Bertelmann E. [1 ]
Joussen A.M. [1 ]
Torun N. [1 ]
Rieck P.W. [2 ]
机构
[1] Klinik für Augenheilkunde, Charité-Universitätsmedizin Berlin, 13353 Berlin, Campus Virchow-Klinikum Berlin
[2] Augenklinik Berlin-Marzahn, Berlin
来源
Der Ophthalmologe | 2014年 / 111卷 / 2期
关键词
Descemet's stripping automated endothelial keratoplasty; Endothelial cell loss; Flap thickness; Preparation technique; Visual acuity;
D O I
10.1007/s00347-013-2795-0
中图分类号
学科分类号
摘要
Background: The aim of this study was to evaluate the effect of donor lamella thickness on postoperative visual acuity after Descemet's stripping automated endothelial keratoplasty (DSAEK). Materials and methods: A retrospective analysis of 65 eyes from 61 patients who underwent DSAEK surgery in cases of Fuchs' corneal dystrophy or bullous keratopathy between 2008 and 2011 was performed. The thickness of donor lamella was measured intraoperatively by ultrasonic pachymetry and postoperatively by anterior segment optical coherence tomography (OCT) and correlated to the visual acuity and number of endothelial cells. Results: The donor lamella thickness measured intraoperatively and postoperatively correlated significantly with each other (r = 0.874, p < 0.001). A significant correlation was found between postoperative corneal lamella thickness measured by anterior segment OCT and visual acuity (r = 0.273, p = 0.028) but not between intraoperative donor lamella thickness measured by ultrasonic pachymetry and visual acuity (r = 0.241, p = 0.103). The postoperative endothelial cell number did not show a correlation with either the intraoperatively or the postoperatively measured donor lamella thickness (r = - 0.059, p = 0.731, r = 0.024, p = 0.869, respectively). Conclusions: Corneal lamella thickness < 120 μm was found to be correlated with a better visual outcome than in cases of thicker corneas > 120 μm. Despite greater difficulty in corneal transplant technique in cases of thinner lamella no increased damage of corneal endothelium was shown. Therefore, DSAEK with corneal lamella thickness < 120 μm is an interesting therapeutic alternative to DMEK. © 2013 Springer-Verlag Berlin Heidelberg.
引用
收藏
页码:128 / 134
页数:6
相关论文
共 50 条
  • [1] Influence of donor lamella thickness on visual acuity after Descemet's stripping automated endothelial keratoplasty (DSAEK)
    Maier, A. -K. B.
    Gundlach, E.
    Klamann, M. K. J.
    Gonnermann, J.
    Bertelmann, E.
    Joussen, A. M.
    Torun, N.
    Rieck, P. W.
    OPHTHALMOLOGE, 2014, 111 (02): : 128 - +
  • [2] Descemet's stripping automated endothelial keratoplasty (DSAEK)
    Cursiefen, C.
    Kruse, F. E.
    OPHTHALMOLOGE, 2009, 106 (10): : 939 - 952
  • [3] Descemet's stripping with automated endothelial keratoplasty (DSAEK)
    Cursiefen, C.
    Kruse, F. E.
    OPHTHALMOLOGE, 2008, 105 (02): : 183 - +
  • [4] Complications of Descemet Stripping Automated Endothelial Keratoplasty (DSAEK)
    Thiel, M. A.
    Bochmann, F.
    Schmittinger-Zirm, A.
    Baenninger, P. B.
    Schmid, M. K.
    Kaufmann, C.
    OPHTHALMOLOGE, 2015, 112 (12): : 969 - 973
  • [5] Complications of Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) [Komplikationen der Descemet Stripping Automatisierten Endothelkeratoplastik (DSAEK)]
    Thiel M.A.
    Bochmann F.
    Schmittinger-Zirm A.
    Bänninger P.B.
    Schmid M.K.
    Kaufmann C.
    Der Ophthalmologe, 2015, 112 (12): : 969 - 973
  • [6] Comparison of the Visual Outcomes of Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK) and Penetrating Keratoplasty
    Chikama, T. -I.
    Sato, Y.
    Morita, Y.
    Yanai, R.
    Yamada, N.
    Morishige, N.
    Nishida, T.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [7] Subconjunctival Emphysema After Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK)
    Ide, Takeshi
    Kymionis, George D.
    Yoo, Sonia H.
    O'Brien, Terrence P.
    OPEN OPHTHALMOLOGY JOURNAL, 2008, 2 : 107 - 108
  • [8] Influence of Donor Thickness on Visual Acuity in Descemet's Stripping Automated Endothelial Keratoplasty
    Kuzman, Tomislav
    Meter, Ana
    Kalauz, Miro
    Masnec, Sanja
    Skegro, Ivan
    Jonjic, Ivana
    JOURNAL OF OPHTHALMIC & VISION RESEARCH, 2022, 17 (04) : 462 - 469
  • [9] Visual quality assessment after DSAEK corneal keratoplasty (Descemet Stripping Automated Endothelial Keratoplasty)
    Guechi, Oualid
    Boiche, Mathilde
    Yahia, Rekia
    Ghetemme, Cedric
    Houmad, Naila
    Baudot, Audrey
    Ameloot, Francois
    Perone, Jean-Marc
    Bertaux, Pierre-jean
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [10] Posteriore lamelläre Keratoplastik (DSAEK)Descemet’s stripping with automated endothelial keratoplasty (DSAEK)
    C. Cursiefen
    F.E. Kruse
    Der Ophthalmologe, 2008, 105 : 183 - 192