Analysis of technical condition and safety of gas-pumping units

被引:1
|
作者
Babichev S.A.
Bychkov E.V.
Kryukov O.V.
机构
关键词
electrically driven gas-pumping unit; monitoring and security systems; motor stator windings;
D O I
10.3103/S1068371210090075
中图分类号
学科分类号
摘要
Statistical data on damage of the stator insulation and operating conditions of high-voltage electrically driven gas-pumping units is analyzed. The most characteristic conditions for the occurrence of insulation breakdown and damage locations are revealed. A theoretical analysis and practical results of the quantitative evaluation of the most significant operational factors that affect the insulation resource are presented. Options to improve the reliability and efficiency of electrically driven gas-pumping units are proposed. © 2010 Allerton Press, Inc.
引用
收藏
页码:489 / 494
页数:5
相关论文
共 50 条
  • [41] Diagnostics of the condition of sucker-rod pumping units after the analysis of dynamogram cards
    Milovzorov, Georgy
    Ilyin, Aleksei
    Shirobokov, Pavel
    INTERNATIONAL CONFERENCE ON MODERN TRENDS IN MANUFACTURING TECHNOLOGIES AND EQUIPMENT: MECHANICAL ENGINEERING AND MATERIALS SCIENCE (ICMTMTE 2019), 2019, 298
  • [42] Problems in stable functioning of gas-pumping plants under conditions of delayed commissioning of compressor station
    Vdovin, A.A.
    2002, Gaz-Ojl Press-Servis
  • [43] Stabilizing the heat-resistant phases in protective coatings of the blading of turbines in gas-pumping aggregates
    N. M. Chigrinova
    Protection of Metals, 2006, 42 : 609 - 615
  • [44] New Gas Pumping Units for Main Gas Pipelines.
    Kotov, Yu.V.
    Teploenergetika, 1984, (01): : 10 - 12
  • [45] Stabilizing the heat-resistant phases in protective coatings of the blading of turbines in gas-pumping aggregates
    Chigrinova, N. M.
    PROTECTION OF METALS, 2006, 42 (06): : 609 - 615
  • [46] THERMAL STATUS OF THE NOISE-AND HEAT-PROTECTIVE HOUSING OF A GAS-TURBINE PLANT IN A GAS-PUMPING UNIT
    Trusov, P. V.
    Charntsev, D. A.
    Pechenkina, A. M.
    CHEMICAL AND PETROLEUM ENGINEERING, 2010, 46 (7-8) : 441 - 445
  • [47] Design and analysis of hydraulic pumping units
    Li, Guixi
    Ma, Rujian
    Wang, Jungang
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION 2007, VOL 4: DESIGN, ANALYSIS, CONTROL AND DIAGNOSIS OF FLUID POWER SYSTEMS, 2008, : 55 - 58
  • [48] Estimating the repairability of blades used in gas pumping units
    Smyslov A.M.
    Bybin A.A.
    Nev'Yantseva R.R.
    Novikov A.V.
    Dement'Ev A.V.
    Thermal Engineering, 2011, 58 (2) : 119 - 125
  • [49] FIELD GAS PRESSURE POWERS PNEUMATIC PUMPING UNITS
    OLIVER, LR
    WORLD OIL, 1972, 174 (04) : 45 - &
  • [50] Analysis of technical condition of lignite-fired power units as the way of reducing the operational risks
    Buchta, Janusz
    Oziemski, Andrzej
    Oziemski, Michal
    PROCEEDINGS OF THE 2019 20TH INTERNATIONAL SCIENTIFIC CONFERENCE ON ELECTRIC POWER ENGINEERING (EPE), 2019, : 513 - 518