Estimation of Doppler shift frequency using selected phase information for high frame rate color flow mapping

被引:4
|
作者
Tanaka N. [1 ]
Ohtsuki S. [2 ]
机构
[1] Department of Electronic Information Systems, Shibaura Institute of Technology, Faculty of Systems Engineering, Omiya, 330-8570
[2] Precision and Intelligence Laboratory, Tokyo Institute of Technology, Midori-ku, Yokohama 226-8503
关键词
Color flow mapping; Doppler shift; Instantaneous frequency; Interference; Pulsed Doppler;
D O I
10.1007/s10396-003-0005-4
中图分类号
学科分类号
摘要
Purpose. We describe a new approach to processing signals used to estimate the Doppler shift frequency in high frame-rate color flow mapping with fewer pulse transmissions. When an ultrasound pulse is transmitted to a large number of scatterers, the echoes from the scatterers overlap and interfere with one another. This interference causes the phase of the received echo signal to fluctuate, thus disturbing the estimated shift in Doppler frequency. The technique proposed here eliminates this disturbed phase information, leaving the remaining information for use in estimating the shift in Doppler frequency. The instantaneous frequency of the echo signal can serve as an index of the influence of interference. Methods. To test this technique in vivo we used radio-frequency echo signals from the carotid artery for simulation and evaluated the error of the estimated Doppler shift frequency in several cases. Conclusion. Performance was enhanced when the number of pulses transmitted was limited and this technique was used. © The Japan Society of Ultrasonics in Medicine 2004.
引用
收藏
页码:5 / 12
页数:7
相关论文
共 50 条
  • [41] QUANTITATION OF CHRONIC AORTIC-INSUFFICIENCY USING COLOR DOPPLER FLOW MAPPING
    BOUCHARD, A
    YOCK, PG
    SCHILLER, NB
    NEWLANDS, JS
    MASSIE, BM
    BOTVINICK, EH
    GREENBERG, B
    CHEITLIN, MD
    CIRCULATION, 1985, 72 (04) : 100 - 100
  • [42] DIAGNOSIS OF POSTLAMINECTOMY ARTERIOVENOUS-FISTULA USING COLOR DOPPLER FLOW MAPPING
    CHEN, IC
    LIN, FC
    CHERN, MS
    YEH, SJ
    WU, DL
    AMERICAN HEART JOURNAL, 1991, 121 (01) : 217 - 219
  • [43] Doppler frequency rate estimation for SAR using match Fourier transform
    Zhu, L
    Wang, SL
    Ni, JL
    Liu, GS
    PROCEEDINGS OF 2003 INTERNATIONAL CONFERENCE ON NEURAL NETWORKS & SIGNAL PROCESSING, PROCEEDINGS, VOLS 1 AND 2, 2003, : 1109 - 1112
  • [44] Estimation of Flow Velocity Fields from Color Doppler Ultrasound Data: Numerical Validation of Vector Flow Mapping
    Uejima, T.
    Sawada, H.
    Aizawa, T.
    Okada, T.
    Harada, A.
    EUROPEAN HEART JOURNAL, 2009, 30 : 49 - 50
  • [45] Improved frame rate using image interpolation for color flow imaging of the heart
    Miyazaki, Toshiya
    Shiba, Akira
    Murakami, Keiichi
    Toriu, Takashi
    Fujitsu Scientific and Technical Journal, 1993, 29 (04): : 350 - 356
  • [46] Doppler frequency shift estimation for rician channel in high-speed mobile communications
    Wang, Xin
    Tan, Zhen-hui
    Zhu, Gang
    Zhong, Zhang-dui
    2006 8TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING, VOLS 1-4, 2006, : 2367 - +
  • [47] Doppler Frequency Shift Estimation on High-Maneuver Airborne Platform Based on UKF
    Yu H.
    Yi N.
    Jiang W.
    Yang F.
    Beijing Daxue Xuebao (Ziran Kexue Ban)/Acta Scientiarum Naturalium Universitatis Pekinensis, 2017, 53 (06): : 1003 - 1010
  • [48] Improved transverse flow estimation using differential maximum Doppler frequency
    Shen, Che-Chou
    Chou, Ching-Han
    Wang, Yu-Chun
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (03): : 420 - 429
  • [49] Nanorod-based flow estimation using a high-frame-rate photoacoustic imaging system
    National Taiwan University, Department of Electrical Engineering, Graduate Institute of Biomedical Electronics and Bioinformation, Number 1, Roosevelt Road, Taipei 106, Taiwan
    不详
    J Biomed Opt, 2007, 6
  • [50] High Frequency Doppler Flow Triggering for 75 MHz Ultra-High Frame Rate 3D Ultrasonic Zebrafish Echocardiography
    Liu, Ting-Yu
    Lee, Po-Yang
    Shih, Cho-Chiang
    Huang, Chih-Chung
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 246 - 249