Intra- and inter-reader reproducibility of blood flow measurements on the ascending aorta and pulmonary artery using cardiac magnetic resonance

被引:0
|
作者
Giovanni Di Leo
Ida Daniela D’Angelo
Marco Alì
Paola Maria Cannaò
Giovanni Mauri
Francesco Secchi
Francesco Sardanelli
机构
[1] Research Hospital Policlinico San Donato,Radiology Unit
[2] Università degli Studi di Milano,Postgraduation School in Radiodiagnostic
[3] Università degli Studi di Milano,PhD Course in Integrative Biomedical Research
[4] Università degli Studi di Milano,Department of Biomedical Science for Health
来源
La radiologia medica | 2017年 / 122卷
关键词
Cardiac magnetic resonance; Reproducibility; Heart valve; Phase-contrast sequences; Blood flow;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of our study was to estimate the intra- and inter-reader reproducibility of blood flow measurements in the ascending aorta and main pulmonary artery using cardiac magnetic resonance (CMR) and a semi-automated segmentation method. The ethics committee approved this retrospective study. A total of 50 consecutive patients (35 males and 15 females; mean age±standard deviation 27±13 years) affected by congenital heart disease were reviewed. They underwent CMR for flow analysis of the ascending aorta and main pulmonary artery (1.5 T, through-plane phase-contrast sequences). Two independent readers (R1, trained radiology resident; R2, lower-trained technician student) obtained segmented images twice (>10-day interval), using a semi-automated method of segmentation. Peak velocity, forward and backward flows were obtained. Bland–Altman analysis was used and reproducibility was reported as complement to 100% of the ratio between the coefficient of repeatability and the mean. R1 intra-reader reproducibility for the aorta was 99% (peak velocity), 95% (forward flow) and 49% (backward flow); for the pulmonary artery, 99%, 91% and 90%, respectively. R2 intra-reader reproducibility was 92%, 91% and 38%; 98%, 86% and 87%, respectively. Inter-reader reproducibility for the aorta was 91%, 85% and 20%; for the pulmonary artery 96%, 75%, and 82%, respectively. Our results showed a good to excellent reproducibility of blood flow measurements of CMR together with a semiautomated method of segmentation, for all variables except the backward flow of the ascending aorta, with a limited impact of operator’s training.
引用
收藏
页码:179 / 185
页数:6
相关论文
共 50 条
  • [41] Training and calibration improve inter-reader reliability of joint damage assessment using magnetic resonance image scoring and computerized erosion volume measurement
    Bird, P
    Joshua, F
    Lassere, M
    Shnier, R
    Edmonds, J
    [J]. JOURNAL OF RHEUMATOLOGY, 2005, 32 (08) : 1452 - 1458
  • [42] Effect of surgical reconstruction on flow profiles in the aorta using magnetic resonance blood tagging
    Fogel, MA
    Weinberg, PM
    Hoydu, AK
    Hubbard, AM
    Rychik, J
    Jacobs, ML
    Fellows, KE
    Haselgrove, J
    [J]. ANNALS OF THORACIC SURGERY, 1997, 63 (06): : 1691 - 1700
  • [43] Intra- and inter-operator repeatability of myocardial blood flow and myocardial flow reserve measurements using rubidium-82 pet and a highly automated analysis program
    Klein, Ran
    Renaud, Jennifer M.
    Ziadi, Maria C.
    Thorn, Stephanie L.
    Adler, Andy
    Beanlands, Rob S.
    deKemp, Robert A.
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2010, 17 (04) : 600 - 616
  • [44] Intra- and inter-operator repeatability of myocardial blood flow and myocardial flow reserve measurements using rubidium-82 pet and a highly automated analysis program
    Ran Klein
    Jennifer M. Renaud
    Maria C. Ziadi
    Stephanie L. Thorn
    Andy Adler
    Rob S. Beanlands
    Robert A. deKemp
    [J]. Journal of Nuclear Cardiology, 2010, 17 : 600 - 616
  • [45] Intra- and inter-tester reproducibility of venous occlusion plethysmography: comparison between a manual and a semi-automatic method of blood flow analysis
    Silva, Bruno Moreira
    Neves, Fabricia Junqueira
    Rocha, Natalia Galito
    Cagy, Mauricio
    de Souza, Marcio Nogueira
    Lucas da Nobrega, Antonio Claudio
    [J]. PHYSIOLOGICAL MEASUREMENT, 2009, 30 (11) : 1267 - 1279
  • [46] Echo-doppler measurements of portal vein and superior mesenteric artery blood flow in humans: Inter- and intra-observer short-term reproducibility
    Iwao, T
    Toyonaga, A
    Shigemori, H
    Oho, K
    Sumino, M
    Sato, M
    Tanikawa, K
    [J]. JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 1996, 11 (01) : 40 - 46
  • [47] An Assessment of the Intra- and Inter-reliability of the Lumbar Paraspinal Muscle Parameters Using CT Scan and Magnetic Resonance Imaging
    Hu, Zhi-Jun
    He, Jian
    Zhao, Feng-Dong
    Fang, Xiang-Qian
    Zhou, Li-Na
    Fan, Shun-Wu
    [J]. SPINE, 2011, 36 (13) : E868 - E874
  • [48] Evaluation of pulmonary blood flow in bilateral bidirectional Glenn shunts: value of 4-D flow cardiac magnetic resonance in the evaluation of pulmonary artery confluence stenosis
    Al Kindi, Faiza
    Maddali, Madan Mohan
    Al Balushi, Asim
    Al Kindi, Hamood
    [J]. CLINICAL CASE REPORTS, 2022, 10 (07):
  • [49] Renal blood flow measurements with use of phase-contrast magnetic resonance imaging: Normal values and reproducibility
    Bax, L
    Bakker, CJG
    Klein, WM
    Blanken, N
    Beutler, JJ
    Mali, WPTRM
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2005, 16 (06) : 807 - 814
  • [50] Evaluation of Flow Pattern in the Ascending Aorta in Patients with Repaired Tetralogy of Fallot Using Four-Dimensional Flow Magnetic Resonance Imaging
    Lee, Suji
    Kim, Young Jin
    Jung, Jo Won
    Choi, Jae Young
    Park, Han Ki
    Shin, Yu Rim
    Choi, Byung Wook
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2019, 20 (09) : 1334 - 1341