Size-exclusion liquid chromatography of poly(N-vinylformamide)s in aqueous solutions

被引:0
|
作者
V. D. Krasikov
N. I. Gorshkov
I. I. Malakhova
O. S. Egorova
Yu. V. Pokhvoshchev
机构
[1] Russian Academy of Sciences,Institute of Macromolecular Compounds
来源
关键词
size-exclusion chromatography; velocity sedimentation; polyelectrolytes; poly(; -vinylamide)s; hydrodynamic sizes; intrinsic viscosity; molecular-weight characteristics;
D O I
暂无
中图分类号
学科分类号
摘要
The exclusion mechanism of the separation of poly(N-vinylformamide) and its derivatives with a cysteamine terminal group in gel permeation chromatography implemented by the suppression of polyelectrolyte swelling and the electroexclusion of macromolecules was established by the transport analytical methods of molecular hydrodynamics (HPLC, velocity sedimentation, and intrinsic viscosity). Based on an analysis of the hydrodynamic characteristics and molecular weights of polymer fractions determined by velocity sedimentation, it was found that the molecular characteristics and polydispersity of the water-soluble poly(N-vinylamide) s of aliphatic carboxylic acids and their derivatives can be calculated with the use of the Benoit universal calibration dependence.
引用
收藏
页码:460 / 467
页数:7
相关论文
共 50 条
  • [21] AQUEOUS SIZE-EXCLUSION CHROMATOGRAPHY OF MICELLES OF POLY(OXYETHYLENE) METHYL-NORMAL-ALKYL ETHERS
    STYRING, MG
    TEO, HH
    PRICE, C
    BOOTH, C
    JOURNAL OF CHROMATOGRAPHY, 1987, 388 (02): : 421 - 427
  • [22] Quantitation in liquid chromatography of polymers: size-exclusion chromatography with dual detection
    Trathnigg, B
    Feichtenhofer, S
    Kollroser, M
    JOURNAL OF CHROMATOGRAPHY A, 1997, 786 (01) : 75 - 84
  • [23] NONIONIC POLYSACCHARIDES AS CALIBRATION STANDARDS FOR AQUEOUS SIZE-EXCLUSION CHROMATOGRAPHY
    DUBIN, PL
    CARBOHYDRATE POLYMERS, 1994, 25 (04) : 295 - 303
  • [24] Aqueous size-exclusion chromatography of cationic polymers for gene delivery
    Jiang, X.
    van der Horst, A.
    van Steenbergen, M. J.
    Akeroyd, N.
    van Nostrum, C. F.
    Schoenmakers, P. J.
    Hennink, W. E.
    JOURNAL OF CONTROLLED RELEASE, 2006, 116 (02) : E69 - E71
  • [25] Determination of Mark-Houwink parameters for poly(N-vinylformamide)
    Singley, EJ
    Daniel, A
    Person, D
    Beckman, EJ
    JOURNAL OF POLYMER SCIENCE PART A-POLYMER CHEMISTRY, 1997, 35 (12) : 2533 - 2534
  • [26] AN OVERVIEW OF SIZE-EXCLUSION CHROMATOGRAPHY
    JOHNSON, JF
    PLASTICS ENGINEERING, 1983, 39 (03) : 50 - 50
  • [27] ALTERNATIVES TO SIZE-EXCLUSION CHROMATOGRAPHY
    REVILLON, A
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1994, 17 (14-15): : 2991 - 3023
  • [28] Size-exclusion chromatography - Foreword
    Heftmann, E
    JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2003, 56 (1-3): : VII - VII
  • [29] Inverse Size-Exclusion Chromatography
    Sepsey, Annamaria
    Bacskay, Ivett
    Felinger, Attila
    ADVANCES IN CHROMATOGRAPHY, VOL 55, 2018, 55 : 205 - 227
  • [30] Hydrodynamic and Conformational Behavior of N-Vinylformamide–Sodium 4-Styrenesulfonate Copolymers in Aqueous Solutions
    O. A. Dommes
    O. V. Okatova
    I. I. Gavrilova
    E. F. Panarin
    G. M. Pavlov
    Polymer Science, Series A, 2023, 65 : 625 - 631