A sequential injection electronic tongue employing the transient response from potentiometric sensors for anion multidetermination

被引:0
|
作者
M. Cortina
A. Duran
S. Alegret
M. del Valle
机构
[1] Autonomous University of Barcelona,Sensors and Biosensors Group, Department of Chemistry
[2] Havana University,Materials and Reactants Institute
来源
Analytical and Bioanalytical Chemistry | 2006年 / 385卷
关键词
Electronic tongue; Artificial neural network; Sequential injection analysis; Sensor array; Anion multidetermination; Transient response;
D O I
暂无
中图分类号
学科分类号
摘要
Intelligent and automatic systems based on arrays of non-specific-response chemical sensors were recently developed in our laboratory. For multidetermination applications, the normal choice is an array of potentiometric sensors to generate the signal, and an artificial neural network (ANN) correctly trained to obtain the calibration model. As a great amount of information is required for the proper modelling, we proposed its automated generation by using the sequential injection analysis (SIA) technique. First signals used were steady-state: the equilibrium signal after a step-change in concentration. We have now adapted our procedures to record the transient response corresponding to a sample step. The novelty in this approach is therefore the use of the dynamic components of the signal in order to better discriminate or differentiate a sample. In the developed electronic tongue systems, detection is carried out by using a sensor array formed by five potentiometric sensors based on PVC membranes. For the developed application we employed two different chloride-selective sensors, two nitrate-selective sensors and one generic response sensor. As the amount of raw data (fivefold recordings corresponding to the five sensors) is excessive for an ANN, some feature extraction step prior to the modelling was needed. In order to attain substantial data reduction and noise filtering, the data obtained were fitted with orthonormal Legendre polynomials. In this case, a third-degree Legendre polynomial was shown to be sufficient to fit the data. The coefficients of these polynomials were the input information fed into the ANN used to model the concentrations of the determined species (Cl−, \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${\text{ NO}}^{{\text{ - }}}_{{\text{3}}} $$\end{document} and \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${\text{HCO}}^{{\text{ - }}}_{{\text{3}}} $$\end{document}). Best results were obtained by using a backpropagation neural network trained with the Bayesian regularisation algorithm; the net had a single hidden layer containing three neurons with the tansig transfer function. The results obtained from the time-dependent response were compared with those obtained from steady-state conditions, showing the former superior performance. Finally, the method was applied for determining anions in synthetic samples and real water samples, where a satisfactory comparison was also achieved.
引用
收藏
页码:1186 / 1194
页数:8
相关论文
共 44 条
  • [21] Use of an electronic tongue based on all-solid-state potentiometric sensors for the quantitation of alkaline ions
    Gallardo, J
    Alegret, S
    Munoz, R
    Leija, L
    Hernandez, PR
    del Valle, M
    ELECTROANALYSIS, 2005, 17 (04) : 348 - 355
  • [22] Potentiometric electronic tongue-flow injection analysis system for the monitoring of heavy metal biosorption processes
    Wilson, D.
    del Valle, M.
    Alegret, S.
    Valderrama, C.
    Florido, A.
    TALANTA, 2012, 93 : 285 - 292
  • [23] Automated resolution of dichlorvos and methylparaoxon pesticide mixtures employing a Flow Injection system with an inhibition electronic tongue
    Valdes-Ramirez, G.
    Gutierrez, M.
    del Valle, M.
    Ramirez-Silva, M. T.
    Fournier, D.
    Marty, J. -L.
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (05): : 1103 - 1108
  • [24] Use of pulse transient response as input information for an automated SIA electronic tongue
    Calvo, Daniel
    Duran, Alejandro
    del Valle, Manuel
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 131 (01) : 77 - 84
  • [25] Non-selective chemical sensors in analytical chemistry: from “electronic nose” to “electronic tongue”
    Y. Vlasov
    Andrey Legin
    Fresenius' Journal of Analytical Chemistry, 1998, 361 : 255 - 260
  • [26] Non-selective chemical sensors in analytical chemistry: from "electronic nose" to "electronic tongue"
    Vlasov, Y
    Legin, A
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 361 (03): : 255 - 260
  • [27] An electronic sensor to characterize transient response of nozzle injection for pesticide spraying
    Crowe, TG
    Downey, D
    Giles, DK
    Slaughter, DC
    TRANSACTIONS OF THE ASAE, 2005, 48 (01): : 73 - 82
  • [28] Sequential injection system with higher dimensional electrochemical sensor signals Part 2.: Potentiometric e-tongue for the determination of alkaline ions
    Cortina, M
    Gutés, A
    Alegret, S
    del Valle, M
    TALANTA, 2005, 66 (05) : 1197 - 1206
  • [29] Automatic sequential injection analysis electronic tongue with integrated reference electrode for the determination of ascorbic acid, uric acid and paracetamol
    Albert Gutés
    Daniel Calvo
    Francisco Céspedes
    Manuel del Valle
    Microchimica Acta, 2007, 157 : 1 - 6
  • [30] Automatic sequential injection analysis electronic tongue with integrated reference electrode for the determination of ascorbic acid, uric acid and paracetamol
    Gutes, Albert
    Calvo, Daniel
    Cespedes, Francisco
    del Valle, Manuel
    MICROCHIMICA ACTA, 2007, 157 (1-2) : 1 - 6