Efficiency of vapor compression heat pumps based on non-azeotropic refrigerant mixtures

被引:1
|
作者
Mezentseva N.N. [1 ]
机构
[1] Kutateladze Institute of Thermophysics SB RAS, Novosibirsk
关键词
energy conversion ratio; heat pump; non-azeotropic refrigerants;
D O I
10.1134/S0869864311020120
中图分类号
学科分类号
摘要
The work presents the results of cycle computation for vapor compression pumps based on ozone-safe mixed refrigerants. Non-azeotropic binary refrugerants R32/R152a (30/70) and R32/R134a (30/70) were considere as working substances. Properties of non-azeotropic refrigerants were calculated according to the additivity method of thermodynamic functions and method of Lemmon and Jacobsen. Deviations in the values of thermophysical properties obtained with two methods have been determined. It is shown that at the use of nonazeotropic mixture R32/R152a (30/70), energy conversion ratio increases by 2.2-3.6 % compared with the results for R32/R134a (30/70) at temperature difference between the processes of boiling and condensation from 28 to 53 °C. © 2011 Pleiades Publishing, Ltd.
引用
收藏
页码:323 / 330
页数:7
相关论文
共 50 条
  • [21] THE ECONOMY OF NONAZEOTROPIC REFRIGERANT MIXTURES IN COMPRESSION HEAT-PUMPS
    OFNER, H
    SCHNITZER, H
    MOSER, F
    JOURNAL OF HEAT RECOVERY SYSTEMS, 1986, 6 (04): : 313 - 321
  • [22] Experiment of flow boiling pressure drop of non-azeotropic refrigerant mixtures in micro-tube
    Hu, Zi-Cheng
    Ma, Hu-Gen
    Jiangsu Daxue Xuebao (Ziran Kexue Ban) / Journal of Jiangsu University (Natural Science Edition), 2007, 28 (05): : 413 - 416
  • [23] Algorithm for non-azeotropic ternary refrigerant mixture thermodynamic properties
    Wu, Xian-Zhong
    Cui, Xiao-Yu
    Ma, Hu-Gen
    Li, Mei-Ling
    Huaxue Gongcheng/Chemical Engineering (China), 2007, 35 (01): : 37 - 39
  • [24] Performance Study of a Water-to-Water Heat Pump Using Non-azeotropic Refrigerant Mixtures R407C
    Abdesselam, H.
    Masjuki, H. H.
    Saidur, R.
    Sattar, M. A.
    Guellal, M.
    INTERNATIONAL ENERGY JOURNAL, 2008, 9 (04): : 267 - 274
  • [25] Forced convection boiling of non-azeotropic mixtures
    Murata, Keiji
    Hashizume, Kenichi
    Nippon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 1988, 54 (506): : 2856 - 2863
  • [26] Investigation on incomplete condensation of non-azeotropic working fluids in high temperature heat pumps
    Pan, G
    Li, Z
    ENERGY CONVERSION AND MANAGEMENT, 2006, 47 (13-14) : 1884 - 1893
  • [27] On the temperature distribution in the counter flow heat exchanger with multicomponent non-azeotropic mixtures
    Gong, MQ
    Luo, EC
    Wu, JF
    Zhou, Y
    CRYOGENICS, 2002, 42 (12) : 795 - 804
  • [28] Peculiarities of determination of the heat transfer coefficient at boiling of non-azeotropic mixtures in tubes
    Mezentseva, N. N.
    Mezentsev, I., V
    ALL-RUSSIAN CONFERENCE XXXIV SIBERIAN THERMOPHYSICAL SEMINAR, DEDICATED TO THE 85TH ANNIVERSARY OF ACADEMICIAN A. K. REBROV, 2018, 1105
  • [29] Exergy modelling of vapour compression heat pumps using refrigerant mixtures
    Stegou-Sagia, Athina
    Papadaki, Argyro
    INTERNATIONAL JOURNAL OF EXERGY, 2006, 3 (03) : 305 - 322
  • [30] The procedures developed of automatic cascade non-azeotropic refrigerant selection and matching
    Zheng Da-yu
    Chen Qiu-yan
    Gao Li-ping
    Liu Lei
    Chen Shuo
    Li Xiang
    Yu Hai-feng
    Li Jie
    PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON ADVANCED DESIGN AND MANUFACTURING ENGINEERING, 2015, 39 : 648 - 652