Prostate intra-fraction motion recorded by transperineal ultrasound

被引:0
|
作者
Ballhausen, Hendrik [1 ]
Belka, Claus [1 ,2 ,3 ]
Li, Minglun [1 ]
机构
[1] Ludwig Maximilians Univ Munchen, LMU Univ Hosp, Dept Radiat Oncol, Munich, Germany
[2] German Canc Consortium DKTK, Partner Site Munich, Munich, Germany
[3] Bavarian Canc Res Ctr BZKF, Munich, Germany
关键词
SYSTEM;
D O I
10.1038/s41597-024-03365-2
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Infra-fraction motion of the prostate was recorded during 3.423 fractions of image guided radiotherapy (IGRT) in 191 patients, 14 of which were treated by intensity modulated radiation therapy (IMRT), and 177 of which were treated by volumetric arc therapy (VMAT). The prostate was imaged by three-dimensional and time-resolved transperineal ultrasound (4D-US) of type Clarity by Elekta AB, Stockholm, Sweden. The prostate volume was registered and the prostate position (center of volume) was recorded at a frequency of 2.0 samples per second. This raw data set contains a total of 1.985.392 prostate and patient couch positions over a time span of 272 hours, 52 minutes and 34 seconds of life radiotherapy as exported by the instrument software. This data set has been used for the validation of models of prostate intra-fraction motion and for the estimation of the dosimetric impact of actual intra-fraction motion on treatment quality and side effects. We hope that this data set may be reused by other groups for similar purposes.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Incorporating intra-fraction motion into IMRT plan optimization
    Shepard, D
    Cao, D
    Earl, M
    Naqvi, S
    D'Souza, W
    MEDICAL PHYSICS, 2005, 32 (06) : 1975 - 1976
  • [42] THE USE OF LAXATIVE AND THE IMPACT ON RECTUM FILLING, INTRA-FRACTION MOTION AND DOSE TO PTV FOR PROSTATE PATIENTS
    Jensen, C.
    Johansen, M.
    Resell, M.
    Kylling, A.
    Skottner, N.
    Fremsaeter, O.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S175 - S176
  • [43] Assessing the Dosimetric Impact of Intra-Fraction Prostate Motion On Step-And-Shoot IMRT Plans
    Langen, K.
    Moore, J.
    Kupelian, P.
    Siebers, J.
    MEDICAL PHYSICS, 2009, 36 (06) : 2550 - +
  • [44] Quantitative investigation of dose accumulation errors from intra-fraction motion in MRgRT for prostate cancer
    Bosma, L. S.
    Zachiu, C.
    Ries, M.
    Denis de Senneville, B.
    Raaymakers, B. W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (06):
  • [45] Inference of Prostate PTV Margins in VMAT Delivery From Intra-Fraction Prostate Motion During SBRT Delivery
    Thind, K.
    Wong, R.
    Wong, D.
    Gerdes, C.
    Chow, T.
    MEDICAL PHYSICS, 2015, 42 (06) : 3637 - 3637
  • [46] Management of intra-fraction motion in prostate radiotherapy: a study of 100 patients imaged for all fractions
    Simpson, J.
    Lehmann, J.
    Greer, P.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S480 - S480
  • [47] Seminal vesicle inter- and intra-fraction motion during radiotherapy for prostate cancer: A review
    Brand, Victor J.
    Milder, Maaike T. W.
    Christianen, Miranda E. M. C.
    Hoogeman, Mischa S.
    Incrocci, Luca
    RADIOTHERAPY AND ONCOLOGY, 2022, 169 : 15 - 24
  • [48] Imaging Frequency And Planning Margins For Non Real Time Intra-fraction Monitoring Of Prostate Motion
    Curtis, W. A.
    Khan, M.
    Stephans, K.
    Tendulkar, R.
    Xia, P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S381 - S382
  • [49] Interplay between Prostate Intra-Fraction Motion and Proton Uniform Scanning Treatment: A Dosimetry Study
    Su, Z.
    Slopsema, R.
    Flampouri, S.
    Li, Z.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [50] Intra-fraction motion detection with Triggered Imaging for prostate cancer patients with implanted gold seeds
    Van der Weide, N. C.
    Admiraal, M. A.
    Rosario, T. S.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S478 - S479