Micro-particle entrainment from density mismatched liquid carrier system

被引:0
|
作者
S. M. Naser Shovon
Adeeb Alam
William Gramlich
Bashir Khoda
机构
[1] The University of Maine,Department of Mechanical Engineering
[2] The University of Maine,Department of Chemistry
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Micro-scale inorganic particles (d > 1 µm) have reduced surface area and higher density, making them negatively buoyant in most dip-coating mixtures. Their controlled delivery in hard-to-reach places through entrainment is possible but challenging due to the density mismatch between them and the liquid matrix called liquid carrier system (LCS). In this work, the particle transfer mechanism from the complex density mismatching mixture was investigated. The LCS solution was prepared and optimized using a polymer binder and an evaporating solvent. The inorganic particles were dispersed in the LCS by stirring at the just suspending speed to maintain the pseudo suspension characteristics for the heterogeneous mixture. The effect of solid loading and the binder volume fraction on solid transfer has been reported at room temperature. Two coating regimes are observed (i) heterogeneous coating where particle clusters are formed at a low capillary number and (ii) effective viscous regime, where full coverage can be observed on the substrate. ‘Zero’ particle entrainment was not observed even at a low capillary number of the mixture, which can be attributed to the presence of the binder and hydrodynamic flow of the particles due to the stirring of the mixture. The critical film thickness for particle entrainment is h∗=0.16a\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${h}^{*}=0.16a$$\end{document} for 6.5% binder and h∗=0.26a\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${h}^{*}=0.26a$$\end{document} for 10.5% binder, which are smaller than previously reported in literature. Furthermore, the transferred particle matrices closely follow the analytical expression (modified LLD) of density matching suspension which demonstrate that the density mismatch effect can be neutralized with the stirring energy. The findings of this research will help to understand this high-volume solid transfer technique and develop novel manufacturing processes.
引用
收藏
相关论文
共 50 条
  • [41] The Micro-Flow Reaction System Featured the Liquid-Liquid Interface Created with Ternary Mixed Carrier Solvents in a Capillary Tube
    Masuhara, Yuji
    Jinno, Naoya
    Hashimoto, Masahiko
    Tsukagoshi, Kazuhiko
    ANALYTICAL SCIENCES, 2012, 28 (05) : 439 - 444
  • [42] MITOTIC CELL-POPULATIONS OBTAINED FROM A MICRO-CARRIER CULTURING SYSTEM
    MITCHELL, KJ
    WRAY, W
    EXPERIMENTAL CELL RESEARCH, 1979, 123 (02) : 452 - 455
  • [44] Effect of the degree of hydrogenation on the viscosity, surface tension, and density of the liquid organic hydrogen carrier system based on diphenylmethane
    Schmidt, Patrick S.
    Kerscher, Manuel
    Klein, Tobias
    Jander, Julius H.
    Bioucas, Francisco E. Berger
    Ruede, Timo
    Li, Shao
    Stadelmaier, Monika
    Hanyon, Samantha
    Fathalla, Ramy R.
    Boesmann, Andreas
    Preuster, Patrick
    Wasserscheid, Peter
    Koller, Thomas M.
    Rausch, Michael H.
    Froeba, Andreas P.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2022, 47 (09) : 6111 - 6130
  • [45] A di-electrophoretic simulation procedure of iron-oxide micro-particle drug attachment system for leukemia treatment using COMSOL software: a potential treatment reference for LMICs
    Kiwumulo, Henry Fenekansi
    Muwonge, Haruna
    Ibingira, Charles
    Lubwama, Michael
    Kirabira, John Baptist
    Ssekitoleko, Robert Tamale
    FRONTIERS IN MEDICAL TECHNOLOGY, 2023, 5
  • [46] Investigation of trace elements in incisor and molar teeth from two different geographical areas in Sudan using micro-particle induced x-ray emission (μ-PIXE)
    Eisa, M. E. M.
    Mars, J. A.
    Naidoo, S.
    Shibrain, R. A.
    Cloete, K. J.
    Maaza, M.
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2023, 36 (02): : 99 - 104
  • [47] Modulation and Optimization of Drug Release from Uncoated Low Density Porous Carrier Based Delivery System
    Sher, Praveen
    Ingavle, Ganesh
    Ponrathnam, Surendra
    Poddar, Pankaj
    Pawar, Atmaram P.
    AAPS PHARMSCITECH, 2009, 10 (02): : 547 - 558
  • [48] Modulation and Optimization of Drug Release from Uncoated Low Density Porous Carrier Based Delivery System
    Praveen Sher
    Ganesh Ingavle
    Surendra Ponrathnam
    Pankaj Poddar
    Atmaram P. Pawar
    AAPS PharmSciTech, 2009, 10 : 547 - 558
  • [49] Comparison of activity behaviors of particle based and monolithic immobilized enzyme reactors operated in semi-micro-liquid chromatography system
    Celebi, Bekir
    Gokaltun, Aslihan
    Tuncel, Ali
    SEPARATION AND PURIFICATION TECHNOLOGY, 2013, 118 : 294 - 299
  • [50] Liquid organic hydrogen carrier hydrogenation-dehydrogenation: From ab initio catalysis to reaction micro-kinetics modelling
    Rakic, Emilija
    Grilc, Miha
    Likozar, Blaz
    CHEMICAL ENGINEERING JOURNAL, 2023, 472