Dynamic multi-section CT imaging in acute myocardial infarction: preliminary animal experience

被引:0
|
作者
Andreas H. Mahnken
Philipp Bruners
Marcus Katoh
Joachim E. Wildberger
Rolf W. Günther
Arno Buecker
机构
[1] RWTH Aachen University,Department of Diagnostic Radiology
来源
European Radiology | 2006年 / 16卷
关键词
Computed tomography; Heart perfusion; Myocardial infarction;
D O I
暂无
中图分类号
学科分类号
摘要
To evaluate the feasibility of myocardial first-pass perfusion imaging with multidetector CT (MDCT). In five pigs, myocardial infaction was induced by permanent balloon occlusion of the left anterior descending coronary artery. Dynamic contrast-enhanced MDCT (12×1.5 mm, 120 kV, 30 mAs, 64 acquisitions, 40 ml iopromide 370@4ml/s) and contrast-enhanced first-pass perfusion magnetic resonance (MR) imaging (TR 7.7 ms/TE 2.6 ms, 64 acquisitions, 0.05 mmol/kg Gd-DTPA) were performed. Finally, the animals were sacrificed, and the heart was excised and stained with triphenyltetrazolin-chloride (TTC). Maximum signal intensity (SImax), contrast material arrival time (CAT), wash-in time (Tmax) and slope were calculated from time-density/signal-intensity curves. The area of myocardial hypoperfusion was measured as the percentage of the left-ventricular area (%LV). Parameters were compared using Bland-Altman plots and Student's t-tests. The hypoperfused area on MDCT was 19.3±4.5%LV (MR imaging 17.2±4.0%LV). The mean size of infarction was 18.7±5.7%LV with TTC. Semiquantitative analysis of MR imaging and MDCT for SImax, Tmax and slope showed significant differences between normal and infarcted myocardium (P<0.05). No significant differences were found for CAT. MDCT and MR imaging both allowed for the differentiation of hypoperfused and normal myocardium. Results given in absolute values differed significantly between both imaging modalities (P<0.05). MDCT has the potential for visual and semiquantitative assessment of first-pass myocardial perfusion.
引用
收藏
页码:746 / 752
页数:6
相关论文
共 50 条
  • [21] GlassNage: Layout Recognition for Dynamic Content Retrieval in Multi-Section Digital Signage
    Mujibiya, Adiyan
    DISTRIBUTED, AMBIENT, AND PERVASIVE INTERACTIONS, 2015, 9189 : 337 - 348
  • [22] Static and dynamic properties of multi-section InGaN-based laser diodes
    Sulmoni, L.
    Lamy, J. -M.
    Dorsaz, J.
    Castiglia, A.
    Carlin, J. -F.
    Scheibenzuber, W. G.
    Schwarz, U. T.
    Zeng, X.
    Boiko, D. L.
    Grandjean, N.
    JOURNAL OF APPLIED PHYSICS, 2012, 112 (10)
  • [23] Quantitative myocardial perfusion analysis using multi-row detector CT in acute myocardial infarction
    Nakauchi, Yoshifumi
    Iwanaga, Yoshitaka
    Ikuta, Shinichiro
    Kudo, Masayuki
    Kobuke, Kazuhiro
    Murakami, Takamichi
    Miyazaki, Shunichi
    HEART, 2012, 98 (07) : 566 - 572
  • [24] ACUTE MYOCARDIAL-INFARCTION - NORTHWOODS EXPERIENCE
    FLETCHER, FW
    WISCONSIN MEDICAL JOURNAL, 1979, 78 (02): : 25 - 28
  • [25] EXPERIENCE IN EMERGENCY TREATMENT OF ACUTE MYOCARDIAL INFARCTION
    Chung Shan Hospital
    Shanghai First Medical College
    and Shanghai Research Institute of Cardiovascular Diseases
    Shanghai
    中华医学杂志(英文版), 1973, (01) : 6 - 6
  • [26] Thrombolysis in acute myocardial infarction: The German experience
    Neuhaus, KL
    vonEssen, R
    Tebbe, U
    Schroeder, R
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 1997, 10 (02) : 101 - 106
  • [27] EXPERIENCE WITH PHENYLINDANEDIONE IN THE MANAGEMENT OF ACUTE MYOCARDIAL INFARCTION
    BRENEMAN, GM
    PRIEST, EM
    AMERICAN HEART JOURNAL, 1955, 50 (01) : 129 - 135
  • [28] Super-resolution reconstruction of pulmonary nodules based on CT multi-section fusion
    Li Y.
    Wang K.
    Zhang L.-B.
    Wang Q.-Z.
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2010, 18 (05): : 1212 - 1218
  • [29] Reperfused myocardial infarction: Contrast-enhanced 64-section CT in comparison to MR imaging
    Nieman, Koen
    Shapiro, Michael D.
    Ferencik, Maros
    Nomura, Cesar H.
    Abbara, Suhny
    Hoffmann, Udo
    Gold, Herman K.
    Jang, Ik-Kyung
    Brady, Thomas J.
    Cury, Ricardo C.
    RADIOLOGY, 2008, 247 (01) : 49 - 56
  • [30] Research on earthquake dynamic behavior of uneven multi-section subway tunnel in transverse direction
    Otsuka, Tsutomu
    Sasaki, Kota
    Nitta, Hiroki
    Konishi, Shinji
    Tsuno, Kiwamu
    Sanagawa, Taisuke
    Tsuchiya, Satoshi
    Maekawa, Koichi
    SOILS AND FOUNDATIONS, 2020, 60 (05) : 1131 - 1150