Visualization of cranial nerves I-XII: Value of 3D CISS and T2-weighted FSE sequences

被引:0
|
作者
Yousry I. [1 ]
Camelio S. [1 ]
Schmid U.D. [2 ]
Horsfield M.A. [3 ]
Wiesmann M. [1 ]
Brückmann H. [1 ]
Yousry T.A. [1 ]
机构
[1] Department of Neuroradiology, Klinikum Grosshadern, Ludwig-Maximilians University, D-81377 Munich
[2] Neurosurgical Unit, Klinik im Park
[3] Department of Medical Physics, University of Leicester
关键词
3D MRI; Cranial nerves; MR imaging; Pulse sequences;
D O I
10.1007/s003300000452
中图分类号
学科分类号
摘要
The aim of this study was to evaluate the sensitivity of the three- dimensional constructive interference od steady state (3D CISS) sequence (slice thickness 0.7 mm) and that of the T2-weighted fast spin echo (T2- weighted FSE) sequence (slice thickness 3 mm) for the visualization of all cranial nerves in their cisternal course. Twenty healthy volunteers were examined using the T2-weighted FSE and the 3D CISS sequences. Three observers evaluated independently the cranial nerves NI-NXII in their cisternal course. The rates for successful visualization of each nerve for 3D CISS (and for T2- weighted FSE in parentheses) were as follows: NI, NII, NV, NVII, NVIII 40 of 40 (40 of 40), NIII 40 of 40 (18 of 40), NIV 19 of 40 (3 of 40), NVI 39 of 40 (5 of 40), NIX, X, XI, 40 of 40 (19 of 40), and NXII 40 of 40 (4 of 40). Most of the cranial nerves can be reliably assessed when using the 3D CISS and the T2-weighted FSE sequences. Increasing the spatial resolution when using the 3D CISS sequence increases the reliability of the identification of the cranial nerves NIII-NXII.
引用
收藏
页码:1061 / 1067
页数:6
相关论文
共 50 条
  • [11] Clinical evaluation of fast 3D half-Fourier FSE for T2-weighted female pelvic MR imaging: Comparison of conventional FSE, single-shot 2D and 3D half-Fourier FSE
    Sugimura, H
    Yamaguchi, K
    Tamura, S
    Machida, Y
    Kitane, S
    Asato, M
    RADIOLOGY, 2000, 217 : 325 - 325
  • [12] Evaluation of 3D T2-weighted Breast MRI
    Moran, C. J.
    Hargreaves, B. A.
    Saranathan, M.
    Daniel, B. L.
    CANCER RESEARCH, 2012, 72
  • [13] Three-dimensional-fast imaging employing steady-state acquisition and T2-weighted fast spin-echo magnetic resonance sequences on visualization of cranial nerves III-XII
    Cheng Yu-Shu
    Zhou Zheng-Rong
    Peng Wei-Jun
    Feng, Tang
    CHINESE MEDICAL JOURNAL, 2008, 121 (03) : 276 - 279
  • [14] Comparison of T2-Weighted 3D-Space and T2-Weighted 2D-TSE Sequences in Lumbar Spine MR Imaging
    Qurat-ul-Ain
    Nadeem, Syed Farrukh
    Mirza, Tariq Mahmood
    Shafiq, Mazhar
    Batool, Zahida
    Khadijah-tul-Kubra
    ANNALS OF KING EDWARD MEDICAL UNIVERSITY LAHORE PAKISTAN, 2023, 29 (04): : 361 - 366
  • [15] MRI ASSESSMENT OF PARATHYROID ADENOMA - THE VALUE OF T2-WEIGHTED SEQUENCES
    BRULE, JM
    DEGEORGES, A
    MAUSS, Y
    JOST, JB
    WENGER, JJ
    LEBRAS, Y
    SCHEIBER, C
    MARESCAUX, J
    CHAMBRON, J
    ANNALES DE RADIOLOGIE, 1989, 32 (06) : 457 - 466
  • [16] MRI ASSESSMENT OF PARATHYROID ADENOMA - THE VALUE OF T2-WEIGHTED SEQUENCES
    BRULE, JM
    DEGEORGES, A
    MAUSS, Y
    JOST, JB
    WENGER, JJ
    LEBRAS, Y
    SCHEIBER, C
    MARESCAUX, J
    CHAMBRON, J
    SEMAINE DES HOPITAUX, 1990, 66 (25): : 1513 - 1522
  • [17] 3D T2-Weighted Spin Echo Imaging in the Breast
    Moran, Catherine J.
    Hargreaves, Brian A.
    Saranathan, Manojkumar
    Lipson, Jafi A.
    Kao, Jennifer
    Ikeda, Debra M.
    Daniel, Bruce L.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (02) : 332 - 338
  • [18] Sensitivity of T2-weighted FSE sequences towards physiological iron depositions in normal brains at 1.5 and 3.0 T
    T. Allkemper
    W. Schwindt
    D. Maintz
    W. Heindel
    B. Tombach
    European Radiology, 2004, 14 : 1000 - 1004
  • [19] Sensitivity of T2-weighted FSE sequences towards physiological iron depositions in normal brains at 1.5 and 3.0 T
    Allkemper, T
    Schwindt, W
    Maintz, D
    Heindel, W
    Tombach, B
    EUROPEAN RADIOLOGY, 2004, 14 (06) : 1000 - 1004
  • [20] Internal Auditory Canal (IAC) and Cerebellopontine Angle (CPA): Comparison between T2-weighted SPACE and 3D-CISS sequences at 1.5T
    Makhamrah, Osama
    Ahmad, Muntaser S.
    Doufish, Dania
    Mohammad, Hjouj
    RADIATION PHYSICS AND CHEMISTRY, 2023, 206