Visualization of cranial nerves I-XII: Value of 3D CISS and T2-weighted FSE sequences

被引:0
|
作者
Yousry I. [1 ]
Camelio S. [1 ]
Schmid U.D. [2 ]
Horsfield M.A. [3 ]
Wiesmann M. [1 ]
Brückmann H. [1 ]
Yousry T.A. [1 ]
机构
[1] Department of Neuroradiology, Klinikum Grosshadern, Ludwig-Maximilians University, D-81377 Munich
[2] Neurosurgical Unit, Klinik im Park
[3] Department of Medical Physics, University of Leicester
关键词
3D MRI; Cranial nerves; MR imaging; Pulse sequences;
D O I
10.1007/s003300000452
中图分类号
学科分类号
摘要
The aim of this study was to evaluate the sensitivity of the three- dimensional constructive interference od steady state (3D CISS) sequence (slice thickness 0.7 mm) and that of the T2-weighted fast spin echo (T2- weighted FSE) sequence (slice thickness 3 mm) for the visualization of all cranial nerves in their cisternal course. Twenty healthy volunteers were examined using the T2-weighted FSE and the 3D CISS sequences. Three observers evaluated independently the cranial nerves NI-NXII in their cisternal course. The rates for successful visualization of each nerve for 3D CISS (and for T2- weighted FSE in parentheses) were as follows: NI, NII, NV, NVII, NVIII 40 of 40 (40 of 40), NIII 40 of 40 (18 of 40), NIV 19 of 40 (3 of 40), NVI 39 of 40 (5 of 40), NIX, X, XI, 40 of 40 (19 of 40), and NXII 40 of 40 (4 of 40). Most of the cranial nerves can be reliably assessed when using the 3D CISS and the T2-weighted FSE sequences. Increasing the spatial resolution when using the 3D CISS sequence increases the reliability of the identification of the cranial nerves NIII-NXII.
引用
收藏
页码:1061 / 1067
页数:6
相关论文
共 50 条
  • [1] Visualization of cranial nerves I-XII:: value of 3D CISS and T2-weighted FSE sequences
    Yousry, I
    Camelio, S
    Schmid, UD
    Horsfield, MA
    Wiesmann, M
    Brückmann, H
    Yousry, TA
    EUROPEAN RADIOLOGY, 2000, 10 (07) : 1061 - 1067
  • [2] Comparison of FSE T2W and 3D FIESTA sequences in the evaluation of posterior fossa cranial nerves with MR cisternography
    Hatipoglu, Hatice Guel
    Durakoglugil, Tugba
    Ciliz, Deniz
    Yueksel, Enis
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2007, 13 (02): : 56 - 60
  • [3] Evaluation of the cranial nerves with inframillimetric T2-weighted imaging
    Benoudiba, F
    Iffenecker, C
    Fuerxer, F
    Huang, J
    Hadj-Rabia, M
    Francke, JP
    Doyon, D
    JOURNAL DE RADIOLOGIE, 1998, 79 (01): : 21 - 25
  • [4] Evaluation of jugular foramen nerves by using b-FFE, T2-weighted DRIVE, T2-weighted FSE and post-contrast T1-weighted MRI sequences
    Aydin, Hasan
    Altin, Elif
    Dilli, Alper
    Sipahioglu, Serdar
    Hekimoglu, Baki
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2011, 17 (01) : 3 - 9
  • [5] Effectiveness of 3D T2-Weighted FLAIR FSE Sequences with Fat Suppression for Detection of Brain MR Imaging Signal Changes in Children
    Mascalchi, M.
    Bianchi, A.
    Basile, M.
    Gulino, P.
    Trifan, M. R.
    Difeo, D.
    Bartolini, E.
    Defilippi, C.
    Diciotti, S.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (12) : 2376 - 2381
  • [6] 2D and 3D-CISS imaging of cranial nerves
    Brechtelsbauer, D
    Bendszus, M
    Hofmann, E
    Warmuth-Metz, M
    Solymosi, L
    RIVISTA DI NEURORADIOLOGIA, 1999, 12 : 179 - 182
  • [7] Diagnostic performance of heavily T2-weighted techniques in obstructive hydrocephalus: comparison study of two different 3D heavily T2-weighted and conventional T2-weighted sequences
    Murat Ucar
    Nil Tokgoz
    Cagri Damar
    Ayse Gul Alimli
    Fatih Oncu
    Japanese Journal of Radiology, 2015, 33 : 94 - 101
  • [8] Diagnostic performance of heavily T2-weighted techniques in obstructive hydrocephalus: comparison study of two different 3D heavily T2-weighted and conventional T2-weighted sequences
    Ucar, Murat
    Tokgoz, Nil
    Damar, Cagri
    Alimli, Ayse Gul
    Oncu, Fatih
    JAPANESE JOURNAL OF RADIOLOGY, 2015, 33 (02) : 94 - 101
  • [9] Comparison of 3D and 2D FSE T2-weighted MRI in the diagnosis of deep pelvic endometriosis: Preliminary results
    Bazot, M.
    Stivalet, A.
    Darai, E.
    Coudray, C.
    Thomassin-Naggara, I.
    Poncelet, E.
    CLINICAL RADIOLOGY, 2013, 68 (01) : 47 - 54
  • [10] Driven equilibrium (drive) MR imaging of the cranial nerves V-VIII: comparison with the T2-weighted 3D TSE sequence
    Ciftci, E
    Anik, Y
    Arslan, A
    Akansel, G
    Sarisoy, T
    Demirci, A
    EUROPEAN JOURNAL OF RADIOLOGY, 2004, 51 (03) : 234 - 240