Quantitative Effects of Contrast Enhanced CT Attenuation Correction on PET SUV Measurements

被引:0
|
作者
Tira Bunyaviroch
Timothy G. Turkington
Terence Z. Wong
John W. Wilson
James G. Colsher
R. Edward Coleman
机构
[1] Duke University Medical Center,Department of Radiology, Nuclear Medicine Section
[2] GE Healthcare Technologies,undefined
来源
关键词
PET/CT; Attenuation correction; Intravenous contrast; Artifacts;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:107 / 113
页数:6
相关论文
共 50 条
  • [21] AN EVALUATION OF SUV ACCURACY IN QUANTITATIVE PET/CT AND SPECT/CT
    Willowson, K.
    Bailey, D.
    Baldock, C.
    Isoardi, R.
    INTERNAL MEDICINE JOURNAL, 2011, 41 : 7 - 7
  • [22] Quantitative SPECT CT of the parathyroid with SUV measurements
    El Khouli, Riham
    Lodge, Martin
    Zeiger, Martha
    Vranesic, Melin
    Ziessman, Harvey
    Szabo, Zsolt
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [23] Effects to the SUV using by high energy X-ray and 137Cs for attenuation correction in PET/CT imaging
    Jeong, Y.
    Kang, D.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S314 - S314
  • [24] PET/CT: Evaluation of The Correction For Attenuation
    Houseni, M.
    Mavi, A.
    Chamroonrat, W.
    Bural, G. G.
    Urhan, M.
    El-Haddad, G.
    Zhuang, H.
    Alavi, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S258 - S258
  • [25] Does chemotherapy influence the quantification of SUV when contrast-enhanced CT is used in PET/CT in lymphoma?
    Pierre Vera
    Matthieu John Ouvrier
    Sébastien Hapdey
    Marc Thillays
    Anne Sophie Pesquet
    Brigitte Diologent
    Françoise Callonec
    Anne Hitzel
    Agathe Edet-Sanson
    Jean François Ménard
    Fabrice Jardin
    Hervé Tilly
    European Journal of Nuclear Medicine and Molecular Imaging, 2007, 34 : 1943 - 1952
  • [26] Does chemotherapy influence the quantification of SUV when contrast-enhanced CT is used in PET/CT in lymphoma?
    Vera, Pierre
    Ouvrier, Matthieu John
    Hapdey, Sebastien
    Thillays, Marc
    Pesquet, Anne Sophie
    Diologent, Brigitte
    Callonec, Francoise
    Hitzel, Anne
    Edet-Sanson, Agathe
    Menard, Jean Francois
    Jardin, Fabrice
    Tilly, Herve
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (12) : 1943 - 1952
  • [27] The effect of radiographic contrast on PET attenuation correction using a hybrid PET-CT device.
    Franquiz, JM
    Ziffer, JA
    Vuong, H
    Young, L
    Lasso, J
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 217P - 217P
  • [28] Method for discrimination of contrast media in CT-based PET attenuation correction.
    Laymon, CM
    Carney, J
    Townsend, D
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 273P - 274P
  • [29] Effects of CT-based attenuation correction on quantitative SPECT/CT of jawbone
    Tsuchitani, Tatsuya
    Kitajima, Kazuhiro
    Takahashi, Yoshiyuki
    Yoshida, Rika
    Kiada, Hayato
    Tsurusaki, Masakatsu
    Minami, Tetsuya
    Kotura, Noriko
    HELLENIC JOURNAL OF NUCLEAR MEDICINE, 2023, 26 (02) : 108 - 113
  • [30] Accuracy of a Topical PET/CT Scanner on SUV Measurements of Small Volumes SUV
    Schelper, Lutz Frank
    Oeri, Milan
    Buchmann, Inga
    CURRENT MEDICAL IMAGING REVIEWS, 2015, 11 (04) : 262 - 271