Base Isolation Versus Dual Design Philosophy for Seismic Design of Buildings: Preliminary Case Study

被引:1
|
作者
Karmakar S. [1 ]
Kumar S. [2 ]
Dutta S.C. [2 ]
Hussain A. [2 ]
机构
[1] School of Infrastructure, Indian Institute of Technology Bhubaneswar, Bhubaneswar, Odisha
[2] Department of Civil Engineering, Indian Institute of Technology-ISM, Dhanbad
关键词
Base isolation; Deformation in base isolator; Performance-based design; Response reduction factor;
D O I
10.1007/s40030-018-0320-9
中图分类号
学科分类号
摘要
The structures are generally designed through dual design philosophy or more broadly known as performance-based design. In this philosophy, the strength is limited to minimize the cost relying on damage-absorbing capacity or ductility capacity of structural members. Still lack of understanding of many issues of nonlinear behavior of structural member makes this method an interesting topic for further research. Base isolation technique is not possible to adopt many a times due to financial limitation. However, this technique may be made more economic and practically implementable through further research. Further, design methodology can also be simplified. Thus, possibly such methodology can be used for an identified class of buildings through further research in this direction. Example case studies presented in the paper for both structures on base isolator and those designed by dual design philosophy clearly indicate intuitively understandable findings. Finally, the paper provides a qualitative insight for economically viable use of base isolation system. It also shows the possibilities of how inelastic excursion-based dual design philosophy can be simultaneously used along with base isolation for reducing the cost further. © 2018, The Institution of Engineers (India).
引用
收藏
页码:627 / 635
页数:8
相关论文
共 50 条
  • [41] Seismic retrofit of church buildings through base isolation
    De Luca, A
    Mele, E
    Giagnuolo, C
    STRUCTURAL CONTROL FOR CIVIL AND INFRASTRUCTURE ENGINEERING, 2001, : 119 - 126
  • [42] Active base isolation of buildings subjected to seismic excitations
    Chang, Chia-Ming
    Spencer, Billie F., Jr.
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2010, 39 (13): : 1493 - 1512
  • [43] Seismic Isolation Design Recommendation in the Important Buildings and Reconstruction Analysis on Seismic Damages of the School Buildings in the Wen chuan Earthquake
    Sun Hong-ling
    Li Hong-pei
    CIVIL ENGINEERING IN CHINA - CURRENT PRACTICE AND RESEARCH REPORT, 2010, : 1106 - 1112
  • [44] Seismic design of buildings in the context of regions: A case study of a site in Semnan city, Iran
    Ghods, Babak
    Rofooei, Fayaz R.
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2024, 186
  • [45] Seismic Upgrade of Existing Buildings with Fluid Viscous Dampers: Design Methodologies and Case Study
    Guo, Tong
    Xu, Jia
    Xu, Weijie
    Di, Zhiqiang
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2015, 29 (06)
  • [46] Influence of seismic design criteria on blast resistance of RC framed buildings: A case study
    Dept. of Structural Engineering, University of Naples Federico II, Via Claudio 21, 80125 Naples, Italy
    Eng. Struct., (78-93):
  • [47] Study on near-fault seismic design spectra based on Chinese code for seismic design of buildings
    Li S.
    Zhou H.
    Liu X.
    Jia J.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2020, 41 (02): : 7 - 12
  • [48] Influence of seismic design criteria on blast resistance of RC framed buildings: A case study
    Parisi, Fulvio
    Augenti, Nicola
    ENGINEERING STRUCTURES, 2012, 44 : 78 - 93
  • [49] Base isolation seismic retrofit of a hospital building in Italy: Design and construction
    Ferraioli, M.
    Avossa, A. M.
    Formato, F.
    COST ACTION C26: URBAN HABITAT CONSTRUCTIONS UNDER CATASTROPHIC EVENTS, 2010, : 835 - 840
  • [50] Direct Displacement-Based Design of Buildings with Different Seismic Isolation Systems
    Cardone, D.
    Palermo, G.
    Dolce, M.
    JOURNAL OF EARTHQUAKE ENGINEERING, 2010, 14 (02) : 163 - 191