Quantitative comparison of technetium-99m tetrofosmin and thallium-201 images of the thyroid and abnormal parathyroid glands

被引:0
|
作者
Alessandro Giordano
Paola Marozzi
Guido Meduri
Umberto Ficola
Maria Lucia Calcagni
Angelo Vaccaro
Giuseppe Rubini
Marco Attard
Maria Li Puma
Riccardo Ricci
Salvatore Corsello
机构
[1] Catholic University of the Sacred Heart,
[2] Department of Nuclear Medicine,undefined
[3] Largo A. Gemelli 8,undefined
[4] I-00168 Roma,undefined
[5] Italy,undefined
[6] Department of Endocrinology,undefined
[7] Catholic University of the Sacred Heart,undefined
[8] Rome,undefined
[9] Italy,undefined
[10] Department of Nuclear Medicine,undefined
[11] Cervello Hospital,undefined
[12] Palermo,undefined
[13] Italy,undefined
[14] Department of Endocrinology,undefined
[15] Cervello Hospital,undefined
[16] Palermo,undefined
[17] Italy,undefined
[18] Department of Nuclear Medicine of the University,undefined
[19] Bari,undefined
[20] Italy,undefined
[21] Department of Pathology,undefined
[22] Catholic University of the Sacred Heart,undefined
[23] Rome,undefined
[24] Italy,undefined
来源
关键词
Key words: Technetium-99m tetrofosmin; Thallium-201; Parathyroid scintigraphy; Thyroid scintigraphy;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of the study was to quantitatively compare the scintigraphic images of the thyroid and abnormal parathyroid glands obtained with technetium-99m tetrofosmin and thallium-201 in patients with hyperparathyroidism. Forty-six patients with hyperparathyroidism underwent 201Tl (74 MBq), 99mTc-pertechnetate (74 MBq) and 99mTc-tetrofosmin (555–740 MBq) scintigraphy in a single session. Image analysis included the computation of the thyroid/background ratio in the whole study population and the parathyroid/background ratio, parathyroid/thyroid ratio and diagnostic sensitivity in 17 patients who underwent parathyroid surgery. The pertechnetate subtraction technique was used. 201Tl and 99mTc-tetrofosmin showed a similar thyroid/background ratio (1.79±0.41 and 1.81±0.47, respectively, P=NS); however, 99mTc-tetrofosmin showed a higher parathyroid/background ratio than 201Tl (2.06±0.54 vs 1.79± 0.50, P=0.007). Despite the superior quality of 99mTc-tetrofosmin images, both tracers showed identical sensitivity in detecting enlarged parathyroid glands in patients with primary hyperparathyroidism (89%) and in those with secondary hyperparathyroidism (50%).
引用
收藏
页码:907 / 911
页数:4
相关论文
共 50 条
  • [41] Value of combined technetium-99m hydroxy methylene diphosphonate and thallium-201 imaging in detecting bone metastases from thyroid carcinoma
    Alam, MS
    Takeuchi, R
    Kasagi, K
    Misaki, T
    Miyamoto, S
    Iida, Y
    Hidaka, A
    Konishi, J
    THYROID, 1997, 7 (05) : 705 - 712
  • [42] Comparison of technetium-99m tetrofosmin and thallium-201 single-photon emission computed tomographic imaging for detection of myocardial perfusion defects in patients with coronary artery disease
    Shanoudy, H
    Raggi, P
    Beller, GA
    Soliman, A
    Ammermann, EG
    Kastner, RJ
    Watson, DD
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 331 - 337
  • [43] Phantom evaluation of simultaneous thallium-201/technetium-99m aquisition in single-photon emission tomography
    Cao, ZJ
    Chen, CC
    Maunoury, C
    Holder, LE
    Abraham, TC
    Tehan, A
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1996, 23 (11): : 1514 - 1520
  • [44] Quantification of left ventricular function with both Thallium-201 and Technetium-99m sestamibi gated SPECT.
    Maunoury, C
    Chen, CC
    Chua, K
    Thompson, C
    Holder, LE
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 408 - 408
  • [45] Technetium-99m(V)-DMSA and thallium-201 in brain tumor imaging: Correlation with histology and malignant grade
    Hirano, T
    Otake, H
    Kazama, K
    Wakabayashi, K
    Zama, A
    Shibasaki, T
    Tamura, M
    Endo, K
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (11) : 1741 - 1749
  • [46] PATHOPHYSIOLOGY OF TECHNETIUM-99M STANNOUS PYROPHOSPHATE AND THALLIUM-201 SCINTIGRAPHY OF ACUTE ANTERIOR MYOCARDIAL INFARCTS IN DOGS
    BUJA, LM
    PARKEY, RW
    STOKELY, EM
    BONTE, FJ
    WILLERSON, JT
    JOURNAL OF CLINICAL INVESTIGATION, 1976, 57 (06): : 1508 - 1522
  • [47] Detection and dosimetry of gamma ray emitted from thallium-201 and technetium-99m based on chemiluminescence technique
    Shourian, Mostafa
    Tavakoli, Hassan
    Ghourchian, Hedayatollah
    Rafiee-Pour, Hossain-Ali
    RADIATION MEASUREMENTS, 2010, 45 (08) : 906 - 910
  • [48] COMPARISON OF REINJECTION THALLIUM-201 AND RESTING TECHNETIUM-99M SESTAMIBI TOMOGRAPHIC-IMAGES FOR THE QUANTIFICATION OF INFARCT SIZE AFTER ACUTE MYOCARDIAL-INFARCTION
    CHRISTIAN, TF
    OCONNOR, MK
    HOPFENSPIRGER, MR
    GIBBONS, RJ
    JOURNAL OF NUCLEAR CARDIOLOGY, 1994, 1 (01) : 17 - 28
  • [49] Technetium-99m tetrofosmin uptake in insular thyroid carcinoma - A comparison with iodine-131
    Degirmenci, B
    Aydin, A
    Comlekci, A
    Ozdogan, O
    Bekis, R
    CLINICAL NUCLEAR MEDICINE, 2003, 28 (05) : 385 - 388
  • [50] Flow versus uptake comparisons of thallium-201 with technetium-99m perfusion tracers in a canine model of myocardial ischemia
    Meleca, MJ
    McGoron, AJ
    Gerson, MC
    Millard, RW
    Gabel, M
    Biniakiewicz, D
    Roszell, NJ
    Walsh, RA
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (12) : 1847 - 1856