Correlation of image quality parameters with tube voltage in X-ray dark-field chest radiography: a phantom study

被引:0
|
作者
Andreas P. Sauter
Jana Andrejewski
Manuela Frank
Konstantin Willer
Julia Herzen
Felix Meurer
Alexander A. Fingerle
Markus R. Makowski
Franz Pfeiffer
Daniela Pfeiffer
机构
[1] Technical University of Munich,Department of Diagnostic and Interventional Radiology, School of Medicine and Klinikum Rechts Der Isar
[2] Technical University of Munich,Chair of Biomedical Physics, Department of Physics and Munich School of BioEngineering
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Grating-based X-ray dark-field imaging is a novel imaging modality with enormous technical progress during the last years. It enables the detection of microstructure impairment as in the healthy lung a strong dark-field signal is present due to the high number of air-tissue interfaces. Using the experience from setups for animal imaging, first studies with a human cadaver could be performed recently. Subsequently, the first dark-field scanner for in-vivo chest imaging of humans was developed. In the current study, the optimal tube voltage for dark-field radiography of the thorax in this setup was examined using an anthropomorphic chest phantom. Tube voltages of 50–125 kVp were used while maintaining a constant dose-area-product. The resulting dark-field and attenuation radiographs were evaluated in a reader study as well as objectively in terms of contrast-to-noise ratio and signal strength. We found that the optimum tube voltage for dark-field imaging is 70 kVp as here the most favorable combination of image quality, signal strength, and sharpness is present. At this voltage, a high image quality was perceived in the reader study also for attenuation radiographs, which should be sufficient for routine imaging. The results of this study are fundamental for upcoming patient studies with living humans.
引用
收藏
相关论文
共 50 条
  • [31] Depiction of pneumothoraces in a large animal model using x-ray dark-field radiography
    Hellbach, Katharina
    Baehr, Andrea
    De Marco, Fabio
    Willer, Konstantin
    Gromann, Lukas B.
    Herzen, Julia
    Dmochewitz, Michaela
    Auweter, Sigrid
    Fingerle, Alexander A.
    Noeel, Peter B.
    Rummeny, Ernst J.
    Yaroshenko, Andre
    Maack, Hanns-Ingo
    Pralow, Thomas
    van der Heijden, Hendrik
    Wieberneit, Nataly
    Proksa, Roland
    Koehler, Thomas
    Rindt, Karsten
    Schroeter, Tobias J.
    Mohr, Juergen
    Bamberg, Fabian
    Ertl-Wagner, Birgit
    Pfeiffer, Franz
    Reiser, Maximilian F.
    SCIENTIFIC REPORTS, 2018, 8
  • [32] X-ray dark-field radiography for in situ gout diagnosis by means of an ex vivo animal study
    Josef Scholz
    Nathalie Roiser
    Eva-Maria Braig
    Christian Petrich
    Lorenz Birnbacher
    Jana Andrejewski
    Melanie A. Kimm
    Andreas Sauter
    Madleen Busse
    Rüdiger Korbel
    Julia Herzen
    Daniela Pfeiffer
    Scientific Reports, 11
  • [33] Directional x-ray dark-field imaging
    Jensen, Torben H.
    Bech, Martin
    Bunk, Oliver
    Donath, Tilman
    David, Christian
    Feidenhans'i, Robert
    Pfeiffer, Franz
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (12): : 3317 - 3323
  • [34] Facilitated Diagnosis of Pneumothoraces in Newborn Mice Using X-ray Dark-Field Radiography
    Hellbach, Katharina
    Yaroshenko, Andre
    Willer, Konstantin
    Pritzke, Tina
    Baumann, Alena
    Hesse, Nina
    Auweter, Sigrid
    Reiser, Maximilian F.
    Eickelberg, Oliver
    Pfeiffer, Franz
    Hilgendorff, Anne
    Meinel, Felix G.
    INVESTIGATIVE RADIOLOGY, 2016, 51 (10) : 597 - 601
  • [35] Grating-based X-ray dark-field imaging: a new paradigm in radiography
    Yaroshenko A.
    Hellbach K.
    Bech M.
    Grandl S.
    Reiser M.F.
    Pfeiffer F.
    Meinel F.G.
    Current Radiology Reports, 2 (7)
  • [36] Artifacts in X-ray Dark-Field Tomography
    Modregger, P.
    Wang, Z.
    Thuering, T.
    Pinzer, B.
    Stampanoni, M.
    10TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2011, 1365 : 269 - 272
  • [37] Artifacts in X-ray dark-field measurements
    Horn, Florian
    Bayer, Florian
    Goedel, Karl
    Haas, Wilhelm
    Pelzer, Georg
    Rieger, Jens
    Ritter, Andre
    Weber, Thomas
    Zang, Andrea
    Durst, Juergen
    Michel, Thilo
    Anton, Gisela
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [38] X-ray Dark-Field Vector Radiography-A Novel Technique for Osteoporosis Imaging
    Baum, Thomas
    Eggl, Elena
    Malecki, Andreas
    Schaff, Florian
    Potdevin, Guillaume
    Gordijenko, Olga
    Garcia, Eduardo Grande
    Burgkart, Rainer
    Rummeny, Ernst J.
    Noel, Peter B.
    Bauer, Jan S.
    Pfeiffer, Franz
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (02) : 286 - 289
  • [39] Trochoidal X-ray Vector Radiography: Directional dark-field without grating stepping
    Sharma, Y.
    Bachche, S.
    Kageyama, M.
    Kuribayashi, M.
    Pfeiffer, F.
    Lasser, T.
    Momose, A.
    APPLIED PHYSICS LETTERS, 2018, 112 (11)
  • [40] X-ray Dark-field Radiography - In-Vivo Diagnosis of Lung Cancer in Mice
    Kai Scherer
    Andre Yaroshenko
    Deniz Ali Bölükbas
    Lukas B. Gromann
    Katharina Hellbach
    Felix G. Meinel
    Margarita Braunagel
    Jens von Berg
    Oliver Eickelberg
    Maximilian F. Reiser
    Franz Pfeiffer
    Silke Meiners
    Julia Herzen
    Scientific Reports, 7