Computer-Aided Detection of Intracranial Aneurysms in MR Angiography

被引:0
|
作者
Xiaojiang Yang
Daniel J. Blezek
Lionel T. E. Cheng
William J. Ryan
David F. Kallmes
Bradley J. Erickson
机构
[1] Mayo Clinic,
[2] Medical Imaging Informatics Innovation Center,undefined
[3] Mayo Clinic,undefined
[4] Department of Radiology,undefined
[5] Mayo Clinic,undefined
[6] College of Medicine,undefined
来源
Journal of Digital Imaging | 2011年 / 24卷
关键词
Computer-aided detection (CAD); magnetic resonance angiography (MRA); intracranial aneurysm; aneurysm detection;
D O I
暂无
中图分类号
学科分类号
摘要
Intracranial aneurysms represent a significant cause of morbidity and mortality. While the risk factors for aneurysm formation are known, the detection of aneurysms remains challenging. Magnetic resonance angiography (MRA) has recently emerged as a useful non-invasive method for aneurysm detection. However, even for experienced neuroradiologists, the sensitivity to small (<5 mm) aneurysms in MRA images is poor, on the order of 30~60% in recent, large series. We describe a fully automated computer-aided detection (CAD) scheme for detecting aneurysms on 3D time-of-flight (TOF) MRA images. The scheme locates points of interest (POIs) on individual MRA datasets by combining two complementary techniques. The first technique segments the intracranial arteries automatically and finds POIs from the segmented vessels. The second technique identifies POIs directly from the raw, unsegmented image dataset. This latter technique is useful in cases of incomplete segmentation. Following a series of feature calculations, a small fraction of POIs are retained as candidate aneurysms from the collected POIs according to predetermined rules. The CAD scheme was evaluated on 287 datasets containing 147 aneurysms that were verified with digital subtraction angiography, the accepted standard of reference for aneurysm detection. For two different operating points, the CAD scheme achieved a sensitivity of 80% (71% for aneurysms less than 5 mm) with three mean false positives per case, and 95% (91% for aneurysms less than 5 mm) with nine mean false positives per case. In conclusion, the CAD scheme showed good accuracy and may have application in improving the sensitivity of aneurysm detection on MR images.
引用
收藏
页码:86 / 95
页数:9
相关论文
共 50 条
  • [31] Automated computer-aided stenosis detection at coronary CT angiography: initial experience
    Elisabeth Arnoldi
    Mulugeta Gebregziabher
    U. Joseph Schoepf
    Roman Goldenberg
    Luis Ramos-Duran
    Peter L. Zwerner
    Konstantin Nikolaou
    Maximilian F. Reiser
    Philip Costello
    Christian Thilo
    European Radiology, 2010, 20 : 1160 - 1167
  • [32] Automatic Computer-Aided Detection of Multiple Sclerosis (MS) Lesions on MR Images
    Eksi, Ziya
    Ozcan, Muhammed Emin
    Aralasmak, Ayse
    Dandil, Emre
    Cakiroglu, Murat
    2015 19TH NATIONAL BIOMEDICAL ENGINEERING MEETING (BIYOMUT), 2015,
  • [33] Computer-Aided Detection of Lung Nodules: Influence of the Image Reconstruction Kernel for Computer-Aided Detection Performance
    Hwang, Jiyoung
    Chung, Myung Jin
    Bae, Younga
    Shin, Kyung Min
    Jeong, Sun Young
    Lee, Kyung Soo
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (01) : 31 - 34
  • [34] An Ellipsoid Convex Enhancement Filter Based Computer-Aided Diagnostic Framework of Intracranial Aneurysms in MRA Images
    Jin, Z.
    Arimura, H.
    Kakeda, S.
    Yamashita, F.
    Sasaki, M.
    Korogi, Y.
    MEDICAL PHYSICS, 2016, 43 (06) : 3885 - 3885
  • [35] Contrast-enhanced MR angiography of intracranial giant aneurysms
    Jäger, HR
    Ellamushi, H
    Moore, EA
    Grieve, JP
    Kitchen, ND
    Taylor, WJ
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2000, 21 (10) : 1900 - 1907
  • [36] Virtual endoscopic MR-angiography in patients with intracranial aneurysms
    Eberhardt, KE
    Hastreiter, P
    Tomandl, B
    Fellner, F
    Huk, WJ
    RADIOLOGY, 1997, 205 : 166 - 166
  • [37] Diagnosis of intracranial aneurysms: Accuracy of MR angiography at 0.5 T
    Grandin, CB
    Mathurin, P
    Duprez, T
    Stroobandt, G
    Hammer, F
    Goffette, P
    Cosnard, G
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1998, 19 (02) : 245 - 252
  • [38] Computer-aided detection for screening mammography
    Woods, K
    Sallam, M
    LASERS IN SURGERY: ADVANCED CHARACTERIZATION, THERAPEUTICS, AND SYSTEMS IX, PROCEEDINGS OF, 1999, 3590 : 490 - 497
  • [39] Computer-aided detection for CT colonography
    Xu Y.-R.
    Zhao J.
    Journal of Shanghai Jiaotong University (Science), 2014, 19 (05) : 531 - 537
  • [40] Computer-aided detection of amorphous calcifications
    Soo, MS
    Rosen, EL
    Xia, JQ
    Ghate, S
    Baker, JA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (03) : 887 - 892