Output optimization of a high-repetition-rate diode-pumped Q-switched intracavity optical parametric oscillator at 1.57 μm

被引:0
|
作者
Y.F. Chen
S.W. Chen
S.W. Tsai
Y.P. Lan
机构
[1] National Chiao Tung University,Department of Electrophysics
[2] National Chiao Tung University,Institute of Electro
来源
Applied Physics B | 2003年 / 77卷
关键词
Output Power; Conversion Efficiency; Input Power; Peak Power; Average Power;
D O I
暂无
中图分类号
学科分类号
摘要
The output optimization of a high-repetition-rate diode-pumped Q-switched intracavity optical parametric oscillator at 1573 nm with a type-II non-critically phase-matched x-cut KTP is experimentally and theoretically studied. The optimum output reflectivity is found to be 85–90% for the maximum average power. The average conversion efficiency from diode-laser input power to OPO signal output power is up to 15% at a pulse repetition of 80 kHz. However, the optimum output reflectivity for the maximum peak power is found to be 60–70%; the overall peak power amounts to 3–4 kW at a pulse repetition of 80 kHz.
引用
收藏
页码:505 / 508
页数:3
相关论文
共 50 条
  • [21] Passively Q-switched diode pumped Nd:YAG laser with intracavity optical parametric oscillator
    Zendzian, W
    Jabczynski, JK
    Kwiatkowski, J
    PHOTONICS, DEVICES, AND SYSTEMS II, 2003, 5036 : 96 - 101
  • [22] Intracavity optical parametric oscillator at 1572-nm wavelength pumped by passively Q-switched diode-pumped Nd:YAG laser
    Zendzian, W
    Jabczynski, JK
    Kwiatkowski, J
    APPLIED PHYSICS B-LASERS AND OPTICS, 2003, 76 (04): : 355 - 358
  • [23] Intracavity optical parametric oscillator at 1572-nm wavelength pumped by passively Q-switched diode-pumped Nd:YAG laser
    W. Zendzian
    J.K. Jabczyński
    J. Kwiatkowski
    Applied Physics B, 2003, 76 : 355 - 358
  • [24] Diode-pumped quasi-cw intracavity optical parametric oscillator at 1.57 μm with efficient pulse shortening
    Agnesi, A.
    Dell'Acqua, S.
    Reali, G.
    Applied Physics B: Lasers and Optics, 2000, 70 (2-6): : 751 - 753
  • [25] Diode-pumped quasi-cw intracavity optical parametric oscillator at 1.57 μm with efficient pulse shortening
    A. Agnesi
    S. Dell’Acqua
    G. Reali
    Applied Physics B, 2000, 70 : 751 - 753
  • [26] Diode-pumped quasi-cw intracavity optical parametric oscillator at 1.57 μm with efficient pulse shortening
    Agnesi, A
    Dell'Acqua, S
    Reali, G
    APPLIED PHYSICS B-LASERS AND OPTICS, 2000, 70 (06): : 751 - 753
  • [27] High Peak Power Eye-Safe Intracavity Optical Parametric Oscillator Pumped by a Diode-Pumped Passively Q-Switched Nd:GGG Laser
    Li, Z-Y
    Huang, H-T
    He, J-L
    Zhang, B-T
    Xu, J-L
    LASER PHYSICS, 2010, 20 (06) : 1302 - 1306
  • [28] Intracavity optical parametric oscillator at 1.57-μm wavelength pumped by passive Q-switched Nd:GdVO4 laser
    Gao, Mingwei
    Gao, Chunqing
    Tang, Kun
    Lin, Zhifeng
    Zhang, Xiuyong
    CHINESE OPTICS LETTERS, 2008, 6 (02) : 127 - 129
  • [29] Intracavity optical parametric oscillator at 1.57-μm wavelength pumped by passive Q-switched Nd:GdVO4 laser
    高明伟
    高春清
    唐坤
    林志峰
    张秀勇
    ChineseOpticsLetters, 2008, (02) : 127 - 129
  • [30] Highly stable and efficient KTP-based intracavity optical parametric oscillator with a diode-pumped passively Q-switched laser
    J. Miao
    B. Wang
    J. Peng
    H. Tan
    H. Bian
    Applied Physics B, 2007, 88 : 193 - 196