Development of a New Suppressor for the Ion Chromatography of Inorganic Cations

被引:0
|
作者
Hiroto Masunaga
Yuji Higo
Mizuo Ishii
Noboru Maruyama
Shigeo Yamazaki
机构
[1] Nichiri Mfg. Co.,Department of Applied Science
[2] Ltd.,undefined
[3] Okayama University of Science,undefined
来源
Analytical Sciences | 2014年 / 30卷
关键词
Ion chromatography; cation analysis; anion removal; suppressor;
D O I
暂无
中图分类号
学科分类号
摘要
This paper reports on a new suppressor that can be used in the ion chromatography (IC) of inorganic cations. The space in which the electrode is set on both sides of the device is separated into three cells using anion- and cation-exchange membranes. Each of the cells is packed with either an anion- or cation-exchange resin. Anions in the eluent and injected sample are removed by electrical regeneration, based on the electrokinetic phenomenon on both the surface of the ion-exchange resins and the membranes. The electrical conductivity of the suppressed eluent reaches a level similar to that of ultrapure water; therefore, a cation detection limit of sub-ppb order is achieved in IC using the device as a suppressor.
引用
收藏
页码:477 / 482
页数:5
相关论文
共 50 条
  • [31] Microcolumn ion chromatography of inorganic monovalent cations with indirect photometric detection and a silica gel column
    Munaf, E
    Zein, R
    Takeuchi, T
    Miwa, T
    ANALYTICA CHIMICA ACTA, 1996, 334 (1-2) : 39 - 43
  • [32] Study of carbonate gradient eluents with the new suppressor in ion chromatography.
    Yan, Z
    Tong, CL
    Liu, WP
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2004, 227 : U102 - U102
  • [33] Computer-assisted Development of ad hoc Methodology for Monitoring of Inorganic Cations in Surface Water Using Gradient Elution Ion Chromatography
    Bolanca, Tomislav
    Ukic, Sime
    Ruzdjak, Andrea Marinovic
    CROATICA CHEMICA ACTA, 2011, 84 (04) : 487 - 492
  • [34] Development of an inorganic cations retention model in ion chromatography by means of artificial neural networks with different two-phase training algorithms
    Bolanca, T
    Cerjan-Stefanovic, S
    Regelja, M
    Regelja, H
    Loncaric, S
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1085 (01) : 74 - 85
  • [35] Recent Progress and Applications of Ion-exclusion/Ion-exchange Chromatography for Simultaneous Determination of Inorganic Anions and Cations
    Nakatani, Nobutake
    Kozaki, Daisuke
    Mori, Masanobu
    Tanaka, Kazuhiko
    ANALYTICAL SCIENCES, 2012, 28 (09) : 845 - 852
  • [36] ANNULAR HELICAL SUPPRESSOR FOR ION CHROMATOGRAPHY
    DASGUPTA, PK
    ANALYTICAL CHEMISTRY, 1984, 56 (01) : 103 - 105
  • [37] ELECTRODIALYTIC MEMBRANE SUPPRESSOR FOR ION CHROMATOGRAPHY
    STRONG, DL
    DASGUPTA, PK
    ANALYTICAL CHEMISTRY, 1989, 61 (09) : 939 - 945
  • [38] Preparation of inorganic ion exchangers for ion chromatography
    Spanos, Emmanquil
    Buchberger, Wolfgang
    American Laboratory, 1996, 28 (10):
  • [39] ION CHROMATOGRAPHY WITH AN ION-EXCHANGE MEMBRANE SUPPRESSOR
    HANAOKA, Y
    MURAYAMA, T
    MURAMOTO, S
    MATSUURA, T
    NANBA, A
    JOURNAL OF CHROMATOGRAPHY, 1982, 239 (APR): : 537 - 548
  • [40] INORGANIC THIN LAYER CHROMATOGRAPHY OF 30 COMMON CATIONS
    SHERWOOD, AE
    METALLURGIA, 1969, 80 (481): : 209 - &