Study on Heat Transfer at Steel-Concrete Interface of Shield Tunnel Composite Segment under Fire

被引:0
|
作者
Wenjun Zhang
Chi Zhang
Gaole Zhang
机构
[1] Tianjin University,Dept. of Civil Engineering
来源
关键词
Fire; Shield tunneling; Composite segment; Steel-concrete interface; Heat transfer;
D O I
暂无
中图分类号
学科分类号
摘要
During the actual construction process and operation period of the tunnel project, due to improper construction operation techniques, long-term load effects, concrete shrinkage and creep, etc., it is difficult for the steel plate and concrete to be in close contact, and there is a void between the two. This results in discontinuous heat transfer. In order to seek the real heat transfer state between steel plate and concrete under high temperature of fire, this paper mainly adopts the methods of model test, theoretical analysis and numerical simulation to study the heat transfer of composite segment steel plate and concrete contact interface under high temperature of fire. The heat transfer process between steel plates and concrete with different thicknesses at different void heights is studied, the temperature time history curve is obtained, and the temperature at the interface and the transition heat transfer coefficient are calculated. The results show that within 5 minutes of the fire, the heat is basically absorbed by the steel plate, the temperature of the concrete is basically unchanged, and the transition heat transfer coefficient rapidly decreases from 1.0 to about 0.2–0.3. When the fire continues to develop, the concrete temperature increases rapidly and the transition heat transfer coefficient increases. With the increase of the void height, the temperature difference between the concrete interface and the steel plate interface gradually increases. According to the data fitting, the relationship between the concrete interface temperature T and the time x and the void height t is obtained. It can be used to calculate the temperature of the concrete interface at a certain moment when the composite segments with different clearance heights are on fire, which has important engineering application value for reducing the adverse consequences of shield tunnel fire.
引用
收藏
页码:3633 / 3647
页数:14
相关论文
共 50 条
  • [41] Experimental study on mechanical performance of steel-concrete girders under fire loading
    Yao W.-F.
    Huang Q.
    Zhang J.-X.
    Yao, Wei-Fa (ywfzjx@163.com), 1600, Tsinghua University (33): : 58 - 65
  • [42] Transfer of the Longitudinal Shear at the Steel-Concrete Interface in Concrete Members Reinforced by Steel Profiles
    Degee, Herve
    Dragan, Dan
    Bogdan, Teodora
    Plumier, Andre
    HIGH TECH CONCRETE: WHERE TECHNOLOGY AND ENGINEERING MEET, 2018, : 1085 - 1092
  • [43] SHEAR STRESSES TRANSFER AT THE STEEL-CONCRETE INTERFACE IN CIRCULAR CONCRETE FILLED STEEL TUBES
    Moga, Catalin
    Gutiu, Stefan I.
    Danciu, Alexandra D.
    GEOCONFERENCE ON NANO, BIO AND GREEN - TECHNOLOGIES FOR A SUSTAINABLE FUTURE, VOL II (SGEM 2014), 2014, : 613 - 619
  • [44] Experimental study on behavior of steel-concrete composite floor with spacial restraints subjected to fire
    Zhang D.
    Zhang J.
    Wang H.
    Dong Y.
    Wang W.
    Li Y.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2022, 43 (02): : 52 - 64
  • [45] Experimental study on fire resistance of reinforced restrained light steel-concrete composite columns
    Song Q.
    Wang W.
    Huang H.
    Liu Y.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2024, 45 (07): : 200 - 211
  • [46] Numerical study on fire resistance of rectangular section stainless steel-concrete composite beam
    Ding, Runmin
    Fan, Shenggang
    Wu, Mingze
    Li, Yang
    FIRE SAFETY JOURNAL, 2021, 125
  • [47] Experimental study on cyclically-damaged steel-concrete composite joints subjected to fire
    Ye, Zhongnan
    Jiang, Shouchao
    Heidarpour, Amin
    Li, Yingchao
    Li, Guoqiang
    STEEL AND COMPOSITE STRUCTURES, 2019, 30 (04): : 351 - 364
  • [48] Numerical study on fire resistance of rectangular section stainless steel-concrete composite beam
    Ding, Runmin
    Fan, Shenggang
    Wu, Mingze
    Li, Yang
    Fire Safety Journal, 2021, 125
  • [49] A new concept for the contact at the interface of steel-concrete composite beams
    Guezouli, Samy
    Alhasawi, Anas
    FINITE ELEMENTS IN ANALYSIS AND DESIGN, 2014, 87 : 32 - 42
  • [50] Evaluation of Composite Steel-Concrete Slab Performance Subjected to Travelling Fire: A Case Study
    Sun, Rui R.
    Wong, Bernice V. Y.
    STRUCTURES IN FIRE, 2016, : 501 - 508