Clinical evaluation of the Nanoduct sweat test system in the diagnosis of cystic fibrosis after newborn screening

被引:0
|
作者
Annette Vernooij-van Langen
Edward Dompeling
Jan-Bart Yntema
Bert Arets
Harm Tiddens
Gerard Loeber
Jeannette Dankert-Roelse
机构
[1] St Jansdal Hospital,Department of Paediatrics
[2] Maastricht University Medical Centre,Department of Paediatric Pulmonology
[3] University Medical Centre Nijmegen-St Radboud,Department of Paediatric Pulmonology
[4] University Medical Centre Utrecht-Wilhelmina’s Children’s Hospital,Department of Paediatric Pulmonology
[5] Sophia Children’s Hospital,Department of Paediatric Pulmonology, Erasmus Medical Centre
[6] National Institute for Public Health and the Environment (RIVM),Laboratory for Infectious Diseases and Perinatal Screening
[7] Atrium Medical Centre,Department of Paediatrics
来源
关键词
Cystic fibrosis; Diagnosis; Infants; Sweat test; Nanoduct;
D O I
暂无
中图分类号
学科分类号
摘要
After a positive newborn screening test for cystic fibrosis (CF), a sweat test is performed to confirm the diagnosis. The success rate of the generally acknowledged methods (Macroduct/Gibson and Cooke) in newborns varies between 73 and 99 %. The Nanoduct sweat test system is easier to perform and less sweat is needed. The main aim of this study was to measure the success rate of the Nanoduct compared to current approved sweat test methods in a newborn population. After informed consent of the parents, newborns with a positive screening test for CF were included. The Macroduct or Gibson and Cooke and Nanoduct were performed in all infants, during the same appointment. The chloride concentration was determined by standard coulorimetry; conductivity was measured directly and converted to a NaCl molarity. One hundred eight newborns were included: 17 with CF, 7 with cystic fibrosis transmembrane regulator (CFTR)-related metabolic syndrome (CRMS), and 84 healthy children. The success rate of the Nanoduct was 93 % and for the Macroduct/Gibson and Cooke 79 % (McNemar, p = 0.002). The Nanoduct detected the same CF patients as the Macroduct/Gibson and Cooke; one CF patient had an equivocal result for both tests, and no patients were missed. The area under the receiver operating characteristic curve for detection of CF with the Nanoduct was 0.999, with ideal cutoff levels of 91 and 66 mmol/l, comparable to former studies.
引用
收藏
页码:1025 / 1034
页数:9
相关论文
共 50 条
  • [21] Nanoduct® sweat conductivity measurements:: a good method for sweat testing in patients with cystic fibrosis
    Desax, M. -C.
    Barben, J.
    Hammer, J.
    Ammann, R. A.
    Schoeni, M. H.
    SWISS MEDICAL WEEKLY, 2006, 136 : 38S - 38S
  • [22] Sweat testing infants detected by cystic fibrosis newborn screening
    Parad, RB
    Comeau, AM
    Dorkin, HL
    Dovey, M
    Gerstle, R
    Martin, T
    O'Sullivan, BP
    JOURNAL OF PEDIATRICS, 2005, 147 (03): : S69 - S72
  • [23] The Need for Quality Improvement in Sweat Testing Infants after Newborn Screening for Cystic Fibrosis
    LeGrys, Vicky A.
    McColley, Susanna A.
    Li, Zhanhai
    Farrell, Philip M.
    JOURNAL OF PEDIATRICS, 2010, 157 (06): : 1035 - 1037
  • [24] Newborn Screening for Cystic Fibrosis: Infant and Laboratory Factors Affecting Successful Sweat Test Completion
    Shenoy, Ambika
    Spyropoulos, Dina
    Peeke, Kathleen
    Smith, Dawn
    Cellucci, Michael
    Chidekel, Aaron
    INTERNATIONAL JOURNAL OF NEONATAL SCREENING, 2021, 7 (01)
  • [25] Phenotype of children with inconclusive cystic fibrosis diagnosis after newborn screening
    Munck, Anne
    Bourmaud, Aurelie
    Bellon, Gabriel
    Picq, Paul
    Farrell, Philip M.
    Deneuville, Eric
    Weiss, Laurence
    Reix, Philippe
    Pin, Isabelle
    Darviot, Estelle
    Bui, Stephanie
    Wizla-Derambure, Nathalie
    Chiron, Raphael
    Foucaud, Pierre
    Rames, Cynthia
    Sermet-Gaudelus, Isabelle
    Corvol, Harriet
    Storni, Veronique
    Rault, Gilles
    Languepin, Jane
    Laurans, Muriel
    Couderc, Laure
    Abely, Michel
    PEDIATRIC PULMONOLOGY, 2020, 55 (04) : 918 - 928
  • [26] RELIABILITY OF THE SWEAT TEST FOR THE DIAGNOSIS OF CYSTIC-FIBROSIS
    SHWACHMAN, H
    CLINICAL CHEMISTRY, 1980, 26 (07) : 988 - 988
  • [27] CYSTIC FIBROSIS NEWBORN SCREENING: THE CASE FOR INVASIVE SURVEILLANCE AFTER DIAGNOSIS
    Stafler, P.
    Davies, J. C.
    Balfour-Lynn, I. M.
    Rosenthal, M.
    Bush, A.
    THORAX, 2009, 64 : A49 - A50
  • [28] THE SWEAT CRYSTALLIZATION TEST IN THE DIAGNOSIS OF CYSTIC-FIBROSIS
    FERRERCALVETE, J
    RIBES, C
    MONTERO, C
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 1990, 10 (03): : 416 - 417
  • [29] Guidelines for the performance of the sweat test for the diagnosis of cystic fibrosis
    Green, Anne
    Kirk, Jean
    ANNALS OF CLINICAL BIOCHEMISTRY, 2007, 44 : 25 - 34
  • [30] Factors accounting for a missed diagnosis of cystic fibrosis after newborn screening
    Rock, Michael J.
    Levy, Hara
    Zaleski, Christina
    Farrell, Philip M.
    PEDIATRIC PULMONOLOGY, 2011, 46 (12) : 1166 - 1174