Low-profile visualized intraluminal support stent for the endovascular treatment of traumatic intracranial internal carotid artery pseudoaneurysms

被引:0
|
作者
Song Tan
Xiaobing Zhou
Yuzhao Lu
Lingfeng Lai
Xiaofei Huang
Bin Li
Yang Wang
机构
[1] First Affiliated Hospital of Nanchang University,Department of Neurosurgery
[2] Nanchang University,Department of Neurosurgery
[3] Beijing Chaoyang Hospital,undefined
[4] Capital Medical University,undefined
来源
Neurosurgical Review | 2022年 / 45卷
关键词
Pseudoaneurysms; Low-profile visualized intraluminal support stent; Internal carotid artery; Trauma;
D O I
暂无
中图分类号
学科分类号
摘要
Optimal treatment strategies for traumatic intracranial internal carotid artery (ICA) pseudoaneurysms are controversial. The low-profile visualized intraluminal support (LVIS) device is a braided stent with a metal coverage rate between traditional laser cut stents and flow diversion devices. We report here our therapy strategy using the LVIS stent-assisted coiling for treatment of traumatic intracranial ICA pseudoaneurysms. Patients with traumatic intracranial ICA pseudoaneurysms treated by the LVIS stent-assisted coiling in our center between January 2015 and June 2021 were reviewed. The complications, radiographic, and clinical outcomes of these patients were analyzed. A total of 12 patients with 12 pseudoaneurysms were included. The mean maximum aneurysm diameter was 6.2 ± 3.1 mm. Nine patients had a subarachnoid hemorrhage; five patients with Hunt-Hess grade III and four patients with grade IV. All procedures were successfully performed without intraoperative complications. Immediate postoperative angiogram showed that six (50%) aneurysms were Raymond grade 1, four (33.3%) were grade 2, and two (16.7%) were grade 3. Postoperative multiple cerebral infarction occurred in two patients because of vasospasm. Of the ten patients with angiographic follow-up (mean, 29.9 months), two received additional coiling because of recanalization of the pseudoaneurysm, and all aneurysms were completely obliterated at the last examination of the patients. During the clinical follow-up period (mean, 26.8 months), the overall mortality and morbidity were 25% (3/12) and 8.3% (1/12), respectively. LVIS stent-assisted coiling was a feasible approach for the treatment of traumatic ICA pseudoaneurysms.
引用
收藏
页码:2231 / 2237
页数:6
相关论文
共 50 条
  • [11] Safety and efficacy of endovascular treatment for tiny ruptured intracranial aneurysms with low-profile visualized intraluminal support stents
    Jin, Yazhou
    Guo, Xinbin
    Quan, Tao
    Chen, Zhen
    Liu, Chao
    Guan, Sheng
    INTERVENTIONAL NEURORADIOLOGY, 2023, 29 (02) : 141 - 147
  • [12] Safety and efficacy of the Low-Profile Visualized Intraluminal Support stent in treating intracranial atherosclerotic stenosis
    Wang, J. -W.
    Li, X. -Y.
    Li, C. -H.
    Liu, J. -F.
    Li, H.
    Tian, Y. -Y.
    Gao, B. -L.
    NEUROLOGIA, 2023, 38 (08): : 521 - 529
  • [13] Endovascular intervention with a low-profile visualized intraluminal support stent for ruptured, very small, wide-necked, intracranial aneurysms
    Li, Jian
    Xu, De-Cai
    Liu, Hou-Yin
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2021, 71 (08) : 1972 - 1975
  • [14] Reconstructive endovascular treatment of vertebral artery dissecting aneurysms with the Low-profile Visualized Intraluminal Support (LVIS) device
    Wang, Chuan-Chuan
    Fang, Yi-Bin
    Zhang, Ping
    Zhu, Xuan
    Hong, Bo
    Xu, Yi
    Liu, Jian-Min
    Huang, Qing-Hai
    PLOS ONE, 2017, 12 (06):
  • [15] Endovascular treatment of PICA aneurysms with a Low-profile Visualized Intraluminal Support (LVIS Jr) device
    Samaniego, Edgar A.
    Abdo, German
    Hanel, Ricardo A.
    Lima, Andrey
    Ortega-Gutierrez, Santiago
    Dabus, Guilherme
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2016, 8 (10) : 1030 - 1033
  • [16] Incomplete stent apposition of low-profile visualized intraluminal support stents in the treatment of cerebral aneurysms
    Zhang, Huan
    Gao, Xiaoping
    Liang, Hui
    Ren, Yi
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2020, 12 (06) : 591 - 597
  • [17] Combined balloon stent technique with the Scepter C balloon and low-profile visualized intraluminal stent for the treatment of intracranial aneurysms
    Spiotta, Alejandro M.
    Miranpuri, Amrendra
    Chaudry, M. Imran
    Turner, Raymond D.
    Turk, Aquilla S.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2013, 5 : III79 - III82
  • [18] Endovascular management of ruptured basilar artery dissection with two overlapping Low-profile Visualized Intraluminal Support stents
    Zhang, Xiaoxi
    Li, Wenshuai
    Lv, Nan
    Zhang, Quanzhong
    Huang, Qinghai
    INTERVENTIONAL NEURORADIOLOGY, 2016, 22 (06) : 659 - 661
  • [19] Using overlapping low-profile visualized intraluminal support stent-assisted coil embolization for treating blood blister-like aneurysms of the internal carotid artery
    Zhang, Xiang
    Shen, Rui
    Zhao, Jingjing
    Sun, Jiping
    Zhang, Quanbin
    Chen, Zuoquan
    NEUROSURGICAL REVIEW, 2021, 44 (02) : 1053 - 1060
  • [20] Using overlapping low-profile visualized intraluminal support stent-assisted coil embolization for treating blood blister-like aneurysms of the internal carotid artery
    Xiang Zhang
    Rui Shen
    Jingjing Zhao
    Jiping Sun
    Quanbin Zhang
    Zuoquan Chen
    Neurosurgical Review, 2021, 44 : 1053 - 1060