Comparison of fluorine-18 and bromine-76 imaging in positron emission tomography

被引:0
|
作者
Maria João Ribeiro
Pedro Almeida
Daniel Strul
Nuno Ferreira
Christian Loc’h
Vincent Brulon
Régine Trébossen
Bernard Mazière
Bernard Bendriem
机构
[1] Service Hospitalier Frédéric Joliot,
[2] CEA,undefined
[3] Orsay,undefined
[4] France,undefined
[5] Serviço de Biofísica – IBILI – FMC,undefined
[6] Coimbra,undefined
[7] Portugal,undefined
来源
关键词
Key words: Positron emission tomography; Quantitation; Regions of interest; Hot spot recovery coefficient; Cold spot recovery coefficient; Positron range;
D O I
暂无
中图分类号
学科分类号
摘要
State of the art positron emission tomography (PET) systems allow for scatter and attenuation correction. However, the size of the structure being studied and the region of interest (ROI) chosen also influence the accuracy of measurements of radioactive concentration. Furthermore, the limited spatial resolution of PET tomographs, which depends, among other factors, on the range of positrons in matter, can also contribute to a loss in quantitation accuracy. In this paper we address the influence of positron range, structure size and ROI size on the quantitation of radioactive concentration using PET. ECAT EXACT HR+ (HR+) and ECAT 953B/31 (ECAT 953B) PET systems were used in phantom acquisitions performed with two radioisotopes with different positron ranges. The 3D Hoffman phantom was scanned on both scanners with both radioisotopes, to visually analyse the image quality. A resolution phantom having six spheres of different diameters in a Plexiglas cylinder was used to calculate the values of the contrast recovery coefficient or hot spot recovery coefficient and of the spill-over or cold spot recovery coefficient under different imaging conditions used in clinical routine at our institution. Activity ratios were varied between 2 and 30 or between 0.4 and 200 by filling the spheres with fluorine-18 or bromine-76 respectively and the cylinder with 11C. Dynamic scans were performed on each scanner. Data were reconstructed using the same parameters as are used in clinical protocols. The variations in sphere and cylinder activities with time were fitted using the function M(t)=k1·A(t)+k2.B(t), where M(t) is the radioactivity concentration measured in an ROI placed on each sphere and A(t) and B(t) represent the true radioactivity concentrations present at time t in the spheres and in the cylinder respectively. k1 and k2 are factors representing the contrast recovery coefficient and the spill-over from surrounding activity on measurements respectively. The visual analysis of images obtained using a 3D Hoffman phantom showed that image resolution and image contrast between different regions are radioisotope dependent and clearly better when using 18F. Linear profiles taken on these images confirmed the visual assessment. For a given scanner, the k1 values obtained with 18F were systematically higher than those measured using 76Br in the same machine (especially for the smaller spheres) when using the same ROI. For a sphere of a particular diameter, the use of a wider ROI resulted in lower quantitative accuracy when using the same isotope and the same camera. Lower quantitative accuracy was found for smaller spheres for all ROI sizes used in image analysis. For the same scanner and for a similar imaging situation (same sphere and same ROI), it was found that k1 and k2 values depend on the radioisotope used. For the same isotope and tomograph, the k1 values obtained decreased with the size of the structures imaged, as well as with the increase in ROI size. The use of a tomograph with better spatial resolution (HR+, rather than ECAT 953B) greatly increased the k1 values for 18F while only a mild improvement in these values was observed for 76Br. The use of 76Br led to k2 values that were slightly higher than those measured using 18F. These differences may have been due to the difference in the range of the positrons emitted by the radioisotopes used in this study. The measurements performed in this study show that the comparison of studies obtained on the same camera depends on the radioisotope used and may require the adaptation of ROI size between examinations. Marked differences are visible if the positron ranges of such radioisotopes are very different. Therefore, when employing commercially available tomographs and imaging protocols used in clinical routine, the effects of differences in positron range on image quality and quantitation are noticeable and correction for these effects may be of importance. With the arrival of PET imaging systems with better spatial resolution (close to 2 mm full-width at half-maximum for animal PET systems), positron range will have an increasing influence on the image quality and on the choice of radioisotope for a given application.
引用
收藏
页码:758 / 766
页数:8
相关论文
共 50 条
  • [31] Diagnosis of a cardiac angiosarcoma by fluorine-18 fluordeoxyglucose positron emission tomography
    L. Freudenberg
    S. Rosenbaum
    J. Schulte-Herbrüggen
    E. Eising
    T. Lauenstein
    A. Wolff
    A. Bockisch
    European Radiology, 2002, 12 : S158 - S161
  • [32] Fluorine-18 FDG positron emission tomography in advanced nasopharyngeal carcinoma
    Nuñez, RF
    Yeung, HWD
    Chisin, R
    CLINICAL NUCLEAR MEDICINE, 2000, 25 (09) : 731 - 733
  • [33] Optimizing myocardial metabolism for fluorine-18 fluorodeoxyglucose positron emission tomography imaging of cardiac inflammation
    Efstathia Andrikopoulou
    Pradeep Bhambhvani
    Journal of Nuclear Cardiology, 2018, 25 : 1372 - 1375
  • [35] Oxime formation for fluorine-18 labeling of peptides and proteins for positron emission tomography (PET) imaging: A review
    Li, Xiang-Guo
    Haaparanta, Merja
    Solin, Olof
    JOURNAL OF FLUORINE CHEMISTRY, 2012, 143 : 49 - 56
  • [36] The use of fluorine-18 fluorodeoxyglucose positron emission tomography for imaging human motor neuronal activation in the brain
    Pahk, Kisoo
    Park, Kun-Woo
    Pyun, Sung Bom
    Lee, Jae Sung
    Kim, Sungeun
    Choe, Jae Gol
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2015, 10 (06) : 2126 - 2130
  • [37] Studies into radiolytic decomposition of fluorine-18 labeled radiopharmaceuticals for positron emission tomography
    Scott, Peter J. H.
    Hockley, Brian G.
    Kung, Hank F.
    Manchanda, Rajesh
    Zhang, Wei
    Kilbourn, Michael R.
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (01) : 88 - 94
  • [38] The role of fluorine-18 fluorodeoxyglucose positron emission tomography in patients with mycosis fungoides
    Alanteri, Eiman
    Usmani, Sharjeel
    Marafi, Fahad
    Esmail, Abulredha
    Ali, Abdullah
    Elhagracy, Rehab S.
    Alshemmari, Salem
    INDIAN JOURNAL OF NUCLEAR MEDICINE, 2015, 30 (03): : 199 - 203
  • [39] Fluorine-18 fluorodeoxyglucose positron emission tomography findings in spondylodiscitis: preliminary results
    A. Schmitz
    J. Risse
    F. Grünwald
    F. Gassel
    H. Biersack
    O. Schmitt
    European Spine Journal, 2001, 10 : 534 - 539
  • [40] Fluorine-18 fluorodeoxyglucose positron emission tomography findings in spondylodiscitis:: preliminary results
    Schmitz, A
    Risse, JH
    Grünwald, F
    Gassel, F
    Biersack, HJ
    Schmitt, O
    EUROPEAN SPINE JOURNAL, 2001, 10 (06) : 534 - 539