A Kinetic Spectrophotometric Method for the Determination of Nitrite by Stopped-Flow Technique

被引:0
|
作者
Rui-Yong Wang
Xiang Gao
Ying-Tang Lu
机构
[1] Wuhan University,Key Laboratory of MOE for Plant Developmental Biology, College of Life Sciences
来源
Analytical Sciences | 2006年 / 22卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A novel and highly sensitive stopped-flow kinetic spectrophotometric method for the determination of nitrite, based on monitoring the variation in the absorbance of the intermediate within a very short period, has been developed. The optimum conditions for various parameters on which the reaction of nitrite with perphenazine depends, were investigated. It was found that the initial reaction rate increased linearly with increasing nitrite concentration in the range from 1.0 × 10-8 to 6.0 × 10-6 M. The detection limit was calculated to be 4.8 × 10-9 M. This method was used for the determination of nitrite in natural and drinking-water with satisfactory results. The influence of cationic, non-ionic and anion surfactants was also studied in this work.
引用
收藏
页码:299 / 304
页数:5
相关论文
共 50 条
  • [31] SIMULTANEOUS KINETIC DETERMINATION OF SECONDARY-AMINES AND THEIR ISOMERS BY A SPECTROPHOTOMETRIC STOPPED-FLOW METHOD BASED ON THE FORMATION OF DIALKYLDITHIOCARBAMATES
    TAGASHIRA, S
    SASAKI, Y
    HAYASHI, K
    FUKUHARA, G
    [J]. ANALYTICA CHIMICA ACTA, 1991, 244 (02) : 239 - 243
  • [32] KINETIC-PHOTOMETRIC DETERMINATION OF SPERMINE, SPERMIDINE AND THEIR MIXTURES BY THE STOPPED-FLOW TECHNIQUE
    GUTIERREZ, MC
    GOMEZHENS, A
    PEREZBENDITO, D
    [J]. FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 331 (06): : 642 - 645
  • [33] KINETIC DETERMINATION OF UREA IN SERUM BY STOPPED-FLOW SPECTROPHOTOMETRY
    ANTON, S
    GUTIERREZ, MC
    GOMEZHENS, A
    PEREZBENDITO, D
    [J]. ANALYTICA CHIMICA ACTA, 1990, 230 (01) : 145 - 150
  • [34] Stopped-flow spectrophotometric determination of hydrogen peroxide with hemoglobin as catalyst
    Zhang, K
    Mao, LY
    Cai, RX
    [J]. TALANTA, 2000, 51 (01) : 179 - 186
  • [35] A surfactant enhanced stopped-flow kinetic fluorimetric method for the determination of trace DNA
    Wang, RY
    Gao, X
    Lu, YT
    [J]. ANALYTICA CHIMICA ACTA, 2005, 538 (1-2) : 151 - 158
  • [36] Simultaneous determination of trace amounts of free cyanide and thiocyanate by a stopped-flow spectrophotometric method
    Sun, BT
    Noller, BN
    [J]. WATER RESEARCH, 1998, 32 (12) : 3698 - 3704
  • [37] Determination of rapid chlorination rate constants by a stopped-flow spectrophotometric competition kinetics method
    Song, Dean
    Liu, Huijuan
    Qiang, Zhimin
    Qu, Jiuhui
    [J]. WATER RESEARCH, 2014, 55 : 126 - 132
  • [38] APPLICATION OF A STOPPED-FLOW TIME-DIFFERENCE TECHNIQUE TO SPECTROPHOTOMETRIC DETERMINATION OF ULTRATRACE LEVELS OF PHOSPHATE
    KANAYA, KI
    HIROMI, K
    [J]. ANALYTICA CHIMICA ACTA, 1987, 203 (01) : 35 - 42
  • [39] SIMULTANEOUS KINETIC-PHOTOMETRIC DETERMINATION OF IMIPRAMINE AND DESIPRAMINE BY STOPPED-FLOW MIXING TECHNIQUE
    DELAPENA, L
    GOMEZHENS, A
    PEREZBENDITO, D
    [J]. ANALYTICA CHIMICA ACTA, 1993, 283 (01) : 471 - 475
  • [40] A STOPPED-FLOW CONTINUOUS-FLOW METHOD FOR KINETIC DETERMINATIONS
    HSIEH, YS
    CROUCH, SR
    [J]. ANALYTICA CHIMICA ACTA, 1995, 309 (1-3) : 277 - 282