Condensation heat transfer and pressure drop characteristics of R-290, R-600a, R-134a and R-22 in horizontal tubes

被引:0
|
作者
Ho-Saeng Lee
Chang-Hyo Son
机构
[1] Pukyong National University,Department of Refrigeration and Air
来源
Heat and Mass Transfer | 2010年 / 46卷
关键词
Heat Transfer Coefficient; Mass Flux; Tube Diameter; Annular Flow; Heat Transfer Coefficient;
D O I
暂无
中图分类号
学科分类号
摘要
This paper presents the experimental results of condensation heat transfer coefficients of hydrocarbon (HC) refrigerants R-290 and R-600a, hydrochlorofluorocarbon (HCFC) refrigerant R-22, and hydrofluorocarbon (HFC) refrigerant R-134a in a horizontal double-pipe heat exchanger having pipe inner diameters of 10.07, 7.73, 6.54, and 5.80 mm. The condensation process experiments were conducted at mass flux of 35.5–210.4 kg/m2 s and condensation temperature of 40°C. The main results were summarized as follows: The average condensation heat transfer coefficients of R-290 and R-600a were higher than those of R-22 and R-134a. The pressure drops of the four refrigerants were in the order of R-600a > R-290 > R-134a > R-22. The pressure drops of R-600a, R-290, R-134a, and R-22 were approximately 6–15, 9.8–12.5, 4.3–6.7, and 2.1–4.6% higher, respectively, in the 10.7 mm diameter tubes compared to the 5.80 mm diameter tubes. Comparing the condensation heat transfer coefficients of our experimental results with those of other correlations, our experimental data in all the test tubes coincided best with that of Haraguchi et al.
引用
下载
收藏
页码:571 / 584
页数:13
相关论文
共 50 条
  • [1] Condensation heat transfer and pressure drop characteristics of R-290, R-600a, R-134a and R-22 in horizontal tubes
    Lee, Ho-Saeng
    Son, Chang-Hyo
    HEAT AND MASS TRANSFER, 2010, 46 (05) : 571 - 584
  • [2] FLOW BOILING HEAT TRANSFER COEFFICIENT OF R-134a/R-290/R-600a MIXTURE IN A SMOOTH HORIZONTAL TUBE
    Balakrishnan, Raja
    Dhasan, Mohan Lal
    Rajagopal, Saravanan
    THERMAL SCIENCE, 2008, 12 (03): : 33 - 44
  • [3] Evaporation heat transfer characteristics of hydrocarbon refrigerants R-290 and R-600a in the horizontal tubes
    Park, Seung-Jun
    Son, Chang-Hyo
    Kim, Jong-Ryul
    Roh, Geon-Sang
    Ku, Hak-Gun
    Park, Gi-Won
    Oh, Hoo-Kyu
    PROCEEDINGS OF THE 3RD ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING VOLS I AND II, 2006, : 285 - +
  • [4] Flow boiling heat transfer coefficient of R-134a/R-290/R-600a mixture in smooth horizontal tubes using varied heat flux method
    Raja, B.
    Lal, D. Mohan
    Saravanan, R.
    APPLIED THERMAL ENGINEERING, 2009, 29 (8-9) : 1778 - 1785
  • [5] A Comparative Study on Flow Boiling Heat-Transfer Coefficient of R-134a and R-134a/R-290/R-600a Refrigerant Mixture
    Raja, Balakrishnan
    Balachander, Palanisamy
    Lal, Dhasan Mohan
    Saravanan, Rajagopal
    HEAT TRANSFER RESEARCH, 2009, 40 (06) : 571 - 588
  • [6] Condensation heat transfer characteristics of R-22, R-134a and R-410A in small diameter tubes
    Son, Chang-Hyo
    Lee, Ho-Saeng
    HEAT AND MASS TRANSFER, 2009, 45 (09) : 1153 - 1166
  • [7] Condensation heat transfer characteristics of R-22, R-134a and R-410A in small diameter tubes
    Chang-Hyo Son
    Ho-Saeng Lee
    Heat and Mass Transfer, 2009, 45 : 1153 - 1166
  • [8] Flow boiling heat transfer study of R-134a/R-290/R-600a mixture in 9.52 and 12.7 mm smooth horizontal tubes: Experimental investigation
    Raja, B.
    Lal, D. Mohan
    Saravanan, R.
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2009, 33 (03) : 542 - 550
  • [9] Condensation heat transfer characteristics of R-22, R-134a and R-410A in a single circular microtube
    Oh, Hoo-Kyu
    Son, Chang-Hyo
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2011, 35 (04) : 706 - 716
  • [10] Condensation heat transfer and pressure drop characteristics of R-600a in horizontal smooth and helically dimpled tubes
    Sarmadian, A.
    Shafaee, M.
    Mashouf, H.
    Mohseni, S. G.
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2017, 86 : 54 - 62