Multi-contrast, isotropic, single-slab 3D MR imaging in multiple sclerosis

被引:0
|
作者
Bastiaan Moraal
Stefan D. Roosendaal
Petra J. W. Pouwels
Hugo Vrenken
Ronald A. van Schijndel
Dominik S. Meier
Charles R. G. Guttmann
Jeroen J. G. Geurts
Frederik Barkhof
机构
[1] VU University Medical Center,Department of Radiology, MS Center Amsterdam
[2] VU University Medical Center,Department of Physics and Medical Technology, MS Center Amsterdam
[3] VU University Medical Center,Department of Informatics, MS Center Amsterdam
[4] Harvard Medical School,Center for Neurological Imaging, Departments of Radiology and Neurology, Brigham and Women’s Hospital
[5] VU University Medical Center,Department of Radiology
来源
European Radiology | 2008年 / 18卷
关键词
DIR; FLAIR; Cortical; Infratentorial; Flow artifacts;
D O I
暂无
中图分类号
学科分类号
摘要
To describe signal and contrast properties of an isotropic, single-slab 3D dataset [double inversion-recovery (DIR), fluid-attenuated inversion recovery (FLAIR), T2, and T1-weighted magnetization prepared rapid acquisition gradient-echo (MPRAGE)] and to evaluate its performance in detecting multiple sclerosis (MS) brain lesions compared to 2D T2-weighted spin-echo (T2SE). All single-slab 3D sequences and 2D-T2SE were acquired in 16 MS patients and 9 age-matched healthy controls. Lesions were scored independently by two raters and characterized anatomically. Two-tailed Bonferroni-corrected Student’s t-tests were used to detect differences in lesion detection between the various sequences per anatomical area after log-transformation. In general, signal and contrast properties of the 3D sequences enabled improved detection of MS brain lesions compared to 2D-T2SE. Specifically, 3D-DIR showed the highest detection of intracortical and mixed WM-GM lesions, whereas 3D-FLAIR showed the highest total number of WM lesions. Both 3D-DIR and 3D-FLAIR showed the highest number of infratentorial lesions. 3D-T2 and 3D-MPRAGE did not improve lesion detection compared to 2D-T2SE. Multi-contrast, isotropic, single-slab 3D MRI allowed an improved detection of both GM and WM lesions compared to 2D-T2SE. A selection of single-slab 3D contrasts, for example, 3D-FLAIR and 3D-DIR, could replace 2D sequences in the radiological practice.
引用
收藏
相关论文
共 50 条
  • [31] Isotropic 3D fast FLAIR imaging of the brain in multiple sclerosis patients: initial experience
    I. Tan
    P. Pouwels
    R. van Schijndel
    H. Adèr
    R. Manoliu
    F. Barkhof
    European Radiology, 2002, 12 : 559 - 567
  • [32] Multi-contrast MR image denoising for parallel imaging using multilayer perceptron
    Kwon, Kinam
    Kim, Dongchan
    Park, HyunWook
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2016, 26 (01) : 65 - 75
  • [33] Accelerated 3d Isotropic High-resolution Multi-contrast Intracranial Vessel Wall MRI For Large Artery Stroke Evaluation
    Balu, Niranjan
    Zhou, Zechen
    Mossa-Basha, Mahmud
    Yuan, Chun
    STROKE, 2017, 48
  • [34] Dual-contrast single breath-hold 3D abdominal MR imaging
    Richard Winkelmann
    Peter Börnert
    Jan De Becker
    Romhild Hoogeveen
    Peter Mazurkewitz
    Olaf Dössel
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2006, 19 : 297 - 304
  • [35] Dual-contrast single breath-hold 3D abdominal MR imaging
    Winkelmann, Richard
    Boernert, Peter
    De Becker, Jan
    Hoogeveen, Romhild
    Mazurkewitz, Peter
    Doessel, Olaf
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2006, 19 (06) : 297 - 304
  • [36] Single-Slab 3D Fast Spin Echo and Its Variants With Very Long Echo Trains for Clinical T2-Weighted Contrast
    Park, Jaeseok
    INVESTIGATIVE MAGNETIC RESONANCE IMAGING, 2023, 27 (04) : 167 - 181
  • [37] Evaluation of 3D multi-contrast carotid vessel wall MRI: a comparative study
    Wei, Hanyu
    Zhang, Miaoqi
    Li, Yunduo
    Zhao, Xihai
    Canton, Gador
    Sun, Jie
    Xu, Dongxiang
    Zhou, Zechen
    Chen, Shuo
    Ferguson, Marina S.
    Hatsukami, Thomas S.
    Li, Rui
    Yuan, Chun
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2020, 10 (01) : 269 - 282
  • [38] Reduction of B1 Sensitivity in Selective Single-Slab 3D Turbo Spin Echo Imaging with Very Long Echo Trains
    Park, Jaeseok
    Mugler, John P., III
    Hughes, Timothy
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (04) : 1060 - 1066
  • [39] Multi-contrast volumetric imaging with isotropic resolution for assessing infarct heterogeneity: Initial clinical experience
    Zhang, Li
    Lai, Peng
    Roifman, Idan
    Pop, Mihaela
    Wright, Graham A.
    NMR IN BIOMEDICINE, 2020, 33 (12)
  • [40] A SELF-ADAPTIVE NETWORK FOR MULTIPLE SCLEROSIS LESION SEGMENTATION FROM MULTI-CONTRAST MRI WITH VARIOUS IMAGING SEQUENCES
    Feng, Yushan
    Pan, Huitong
    Meyer, Craig
    Feng, Xue
    2019 IEEE 16TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2019), 2019, : 472 - 475