Dose rate evaluation in a laboratory for prompt gamma neutron activation analysis by Monte Carlo simulation

被引:0
|
作者
Haoyu Lei
Wenbao Jia
Daqian Hei
Youtao Gao
Can Cheng
Dong Zhao
机构
[1] Nanjing University of Aeronautics and Astronautics,College of Materials Science and Engineering
[2] Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions,School of Nuclear Science and Technology
[3] Lanzhou University,College of Astronautics
[4] Nanjing University of Aeronautics and Astronautics,undefined
关键词
D–T neutron generator; Dose; Monte Carlo simulation; Activation technique;
D O I
暂无
中图分类号
学科分类号
摘要
As an excellent tool, neutron generators have been used widely in prompt gamma-ray neutron activation analysis (PGNAA) technology. In this work, a new PGNAA laboratory was proposed to equip a D–T neutron generator. For safety reasons, radiation shielding of the laboratory was designed, and its protection efficiency was validated by using MCNP simulations and experiments. The results show that the proposed shielding can meet the radiation protection set by the International Commission on Radiological Protection and the Chinese government.
引用
收藏
页码:477 / 483
页数:6
相关论文
共 50 条
  • [31] An Optimal Experimental-Monte Carlo Combined Model for Analyzing of the Cement Raw by Prompt Gamma Neutron Activation
    S. Z. Islami Rad
    R. Gholipour Peyvandi
    [J]. Russian Journal of Nondestructive Testing, 2018, 54 : 448 - 454
  • [32] APPLICATION OF THE MONTE CARLO TECHNIQUE TO THE STUDY OF RADIATION TRANSPORT IN A PROMPT GAMMA IN VIVO NEUTRON ACTIVATION SYSTEM.
    Univ of Auckland, Dep of Surgery, & Physics, Auckland, NZ, Univ of Auckland, Dep of Surgery & Physics, Auckland, NZ
    [J]. Australasian Physical and Engineering Sciences in Medicine, 1985, 8 (01): : 22 - 31
  • [33] An Optimal Experimental-Monte Carlo Combined Model for Analyzing of the Cement Raw by Prompt Gamma Neutron Activation
    Rad, S. Z. Islami
    Peyvandi, R. Gholipour
    [J]. RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 2018, 54 (06) : 448 - 454
  • [34] Evaluation of Monte Carlo codes for dose monitoring using PET and prompt gamma imaging in proton therapy
    Robert, Charlotte
    Dedes, George
    Battistoni, Giuseppe
    Lestand, Loic
    Gueth, Pierre
    Prezado, Yolanda
    Testa, Etienne
    Montarou, Gerard
    Sarrut, David
    Buvat, Irene
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [35] Estimation of absorbed gamma dose rate from granite by Monte Carlo simulation approach
    Knezevic, J.
    Kuzmanovic, P.
    Mrdja, D.
    Todorovic, N.
    Bikit, I
    Hansman, J.
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2020, 40 (02) : 596 - 611
  • [36] Tomographic image of prompt gamma ray from boron neutron capture therapy: A Monte Carlo simulation study
    Yoon, Do-Kun
    Jung, Joo-Young
    Hong, Key Jo
    Suh, Tae Suk
    [J]. APPLIED PHYSICS LETTERS, 2014, 104 (08)
  • [37] A deep learning approach for converting prompt gamma images to proton dose distributions: A Monte Carlo simulation study
    Liu, Chih-Chieh
    Huang, Hsuan-Ming
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 69 : 110 - 119
  • [38] Monte Carlo Simulation of k0 Instrumental Neutron Activation Analysis
    Gacnik, Lojze
    Jacimovic, Radojko
    [J]. 30TH INTERNATIONAL CONFERENCE NUCLEAR ENERGY FOR NEW EUROPE (NENE 2021), 2021,
  • [39] Investigation of phenomenological models for the Monte Carlo simulation of the prompt fission neutron and γ emission
    Litaize, O.
    Serot, O.
    [J]. PHYSICAL REVIEW C, 2010, 82 (05):
  • [40] Investigation of Prompt Fission Neutrons and Gamma-rays by Monte Carlo Simulation
    Litaize, O.
    Serot, O.
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2011, 59 (02) : 991 - 994