Keratometry with five different techniques: a study of device repeatability and inter-device agreement

被引:0
|
作者
Shiva Mehravaran
Soheila Asgari
Sara Bigdeli
Ashkan Shahnazi
Hassan Hashemi
机构
[1] Noor Eye Hospital,Noor Ophthalmology Research Center
来源
关键词
Keratometry; Javal manual keratometer; Topcon automated kerato-refractometer; IOLMaster; EyeSys Corneal Analysis System; Pentacam Scheimpflug Topography System;
D O I
暂无
中图分类号
学科分类号
摘要
The purpose of this study was to determine and compare the repeatability of keratometry measurements with the Javal manual keratometer, Topcon automated kerato-refractometer, IOLMaster, EyeSys Corneal Analysis System, and Pentacam Scheimpflug Topography System, and determine the agreement of measurements of the latter four devices with the Javal keratometer as the gold standard. In this cross-sectional study, 21 people with no history of ocular disease or surgery were examined twice with each device. Minimum, maximum, and average keratometry readings were recorded in diopters (D) for each eye and used in the analyses. For statistical analysis, we determined correlation coefficients and used the Bland–Altman method and calculated the 95 % limits of agreement (LoA). All repeatability coefficients were satisfactorily high. Best repeatability for minimum keratometry and maximum keratometry readings was seen with IOLMaster (95 % LoA −0.23 to 0.19 D and −0.31 to 0.32 D, respectively). Agreement with Javal manual keratometry was best with Topcon and IOLMaster for minimum keratometry readings (95 % LoA −0.67 to 0.28 D and −0.57 to 0.38 D, respectively), and with Topcon for maximum keratometry readings (95 % LoA −0.85 to 0.63 D). In our series of normal eyes, keratometry readings with Topcon, IOLMaster, and Pentacam showed very good agreement with Javal measurements, and inter-device agreements were better than the repeatability of the manual gold standard. However, differences between Javal and EyeSys may not be clinically acceptable, and these two devices should not be used interchangeably. Further studies are needed to investigate these issues in non-virgin eyes.
引用
收藏
页码:869 / 875
页数:6
相关论文
共 50 条
  • [1] Keratometry with five different techniques: a study of device repeatability and inter-device agreement
    Mehravaran, Shiva
    Asgari, Soheila
    Bigdeli, Sara
    Shahnazi, Ashkan
    Hashemi, Hassan
    INTERNATIONAL OPHTHALMOLOGY, 2014, 34 (04) : 869 - 875
  • [2] Repeatability and Inter-device Agreement for Three Different Methods of Keratometry: Placido, Scheimpflug, and Color LED Corneal Topography
    Hidalgo, Irene Ruiz
    Rozema, Jos J.
    Dhubhghaill, Sorcha Ni
    Zakaria, Nadia
    Koppen, Carina
    Tassignon, Marie-Jose
    JOURNAL OF REFRACTIVE SURGERY, 2015, 31 (03) : 176 - U104
  • [3] OPD-Scan III: a repeatability and inter-device agreement study of a multifunctional device in emmetropia, ametropia, and keratoconus
    Soheila Asgari
    Hassan Hashemi
    Ebrahim Jafarzadehpur
    Alireza Mohamadi
    Farhad Rezvan
    Akbar Fotouhi
    International Ophthalmology, 2016, 36 : 697 - 705
  • [4] OPD-Scan III: a repeatability and inter-device agreement study of a multifunctional device in emmetropia, ametropia, and keratoconus
    Asgari, Soheila
    Hashemi, Hassan
    Jafarzadehpur, Ebrahim
    Mohamadi, Alireza
    Rezvan, Farhad
    Fotouhi, Akbar
    INTERNATIONAL OPHTHALMOLOGY, 2016, 36 (05) : 697 - 705
  • [5] Inter-operator and inter-device agreement and reliability of the SEM Scanner
    Clendenin, Marta
    Jaradeh, Kindah
    Shamirian, Anasheh
    Rhodes, Shannon L.
    JOURNAL OF TISSUE VIABILITY, 2015, 24 (01) : 17 - 23
  • [6] Assessment of inter-device agreement in quantifying choriocapillaris flow deficits in normal eyes
    Gnanaraj, Ramya
    Corradetti, Giulia
    Kadomoto, Shin
    Byon, Iksoo
    Ji, Yongsok
    Su, Li
    Taweebanjongsin, Wongsiri
    Sadda, Srinivas
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (09)
  • [7] Inter-device reliability of DSI measurement
    Aichinger, Philipp
    Feichter, Felicitas
    Aichstill, Birgitta
    Bigenzahn, Wolfgang
    Schneider-Stickler, Berit
    LOGOPEDICS PHONIATRICS VOCOLOGY, 2012, 37 (04) : 167 - 173
  • [8] A framework for bimanual inter-device interactions
    Roudaki, Ali
    Kong, Jun
    Walia, Gursimran
    Huang, Zheng
    JOURNAL OF VISUAL LANGUAGES AND COMPUTING, 2014, 25 (06): : 727 - 737
  • [9] Internet 0 - inter-device internetworking
    Krikorian, R
    Gershenfeld, N
    BT TECHNOLOGY JOURNAL, 2004, 22 (04) : 278 - 284
  • [10] Optical coherence tomography of the retina in schizophrenia: Inter-device agreement and relations with perceptual function
    Miller, Margaret
    Zemon, Vance
    Nolan-Kenney, Rachel
    Balcer, Laura J.
    Goff, Donald C.
    Worthington, Michelle
    Hasanaj, Lisena
    Butler, Pamela D.
    SCHIZOPHRENIA RESEARCH, 2020, 219 : 13 - 18