Estimation of hydraulic parameters in a hard rock aquifer using integrated surface geoelectrical method and pumping test data in southeast Guangdong, China

被引:0
|
作者
Muhammad Hasan
Yanjun Shang
Weijun Jin
Gulraiz Akhter
机构
[1] Chinese Academy of Sciences,Key Laboratory of Shale Gas and Geoengineering, Institute of Geology and Geophysics
[2] Chinese Academy of Sciences,Institutions of Earth Science
[3] University of Chinese Academy of Sciences,Department of Earth Sciences
[4] Quaid-i-Azam University,undefined
来源
Geosciences Journal | 2021年 / 25卷
关键词
geophysical method; hydraulic conductivity; transmissivity; groundwater; weathered rock;
D O I
暂无
中图分类号
学科分类号
摘要
Estimation of hydraulic parameters is important for the prediction of the future availability of groundwater reserves. Conventionally, pumping tests are conducted on boreholes to measure these parameters. However, such tests are costly and time consuming, and can only provide limited spatial information. An integrated approach of geophysical method and pumping tests is cost-effective and efficient alternative for the estimation of aquifer parameters. A geophysical method of vertical electrical sounding (VES) was carried out in Huizhou ADS site of China for the delineation of aquifer potential zones to assess the groundwater resources contained within the weathered rock. Initially, the pumping test data were used to determine the hydraulic parameters namely hydraulic conductivity (Kw) and transmissivity (Tw) for available production wells. Afterwards, one empirical relation between pumped hydraulic conductivity (Kw) and aquifer resistivity (ρa), and another between pumped transmissivity (Tw) and transverse resistance (Tr) were obtained to estimate hydraulic conductivity (K) and transmissivity (T) for all VES stations where pumping tests were not conducted. In this way, the entire study area was investigated to delineate the aquifer potential zones i.e., high potential aquifer zone with ρa < 100 Ωm, T > 150 m2/day and K > 4 m/day, medium potential aquifer zone with ρa ranging from 100 to 150 Ωm, T from 100 to 150 m2/day and K from 3 to 4 m/day, poor potential aquifer zone with ρa from 150 to 300 Ωm, T from 50 to 100 m2/day and K from 2 to 3 m/day, and negligible potential aquifer zone with ρa > 300 Ωm, T < 50 m2/day and K < 2 m/day. This investigation also deciphers functional analogous relation of Ωa with K and Tr with T in Huizhou, China. Therefore, similar integrated approach can be used in any geological similar area where the aquifer properties are required for the management of groundwater reserves.
引用
收藏
页码:223 / 242
页数:19
相关论文
共 48 条