Pencil-beam versus fan-beam dual-energy X-ray absorptiometry comparisons across four systems: appendicular lean soft tissue

被引:0
|
作者
E. Ioannidou
J. Padilla
J. Wang
S. B. Heymsfield
J. C. Thornton
M. Horlick
D. Gallagher
R. N. Pierson
机构
[1] New York Obesity Research Center,New York Obesity Research Center St. Luke’s
[2] Columbia University,Roosevelt Hospital, Institute of Human Nutrition College of Physicians and Surgeons
来源
Acta Diabetologica | 2003年 / 40卷
关键词
Body composition; Skeletal muscle mass;
D O I
暂无
中图分类号
学科分类号
摘要
Dual-energy X-ray absorptiometry (DXA) provides an important opportunity for estimating total body skeletal muscle (SM) mass from DXA-measured appendicular lean soft tissue (ALST). A DXA SM prediction model was developed with magnetic resonance imaging as the reference and ALST (i. e., sum of arm plus leg lean soft tissue) as a main predictor variable. In the present study we examined whether ALST estimates are comparable across systems (i. e., penciland fan-beam) and manufacturers. Pencil-beam systems (Lunar DPX and DPX-L) are usually considered more accurate but slower than fan-beam systems (Lunar Prodigy and Hologic Delphi A). In this study we compared ALST estimates in 35 healthy adults across these four systems. The methods gave similar group mean (±SD) values and were highly intercorrelated. There was no significant bias detected across the four systems. ALST estimates from the evaluated DXA systems are comparable and thus appear interchangeable as methods for quantifying total body SM in vivo.
引用
收藏
页码:s83 / s85
相关论文
共 50 条
  • [1] Pencil-beam versus fan-beam dual-energy X-ray absorptiometry comparisons across four systems: appendicular lean soft tissue
    Ioannidou, E
    Padilla, J
    Wang, J
    Heymsfield, SB
    Thornton, JC
    Horlick, M
    Gallagher, D
    Pierson, RN
    [J]. ACTA DIABETOLOGICA, 2003, 40 (Suppl 1) : S83 - S85
  • [2] Pencil-beam vs fan-beam dual-energy X-ray absorptiometry comparisons across four systems
    Soriano, JMP
    Ioannidou, E
    Wang, J
    Thornton, JC
    Horlick, MN
    Gallagher, D
    Heymsfield, SB
    Pierson, RN
    [J]. JOURNAL OF CLINICAL DENSITOMETRY, 2004, 7 (03) : 281 - 289
  • [3] Interchangeability of pencil-beam and fan-beam dual-energy X-ray absorptiometry measurements in piglets and infants
    Koo, WWK
    Hammami, M
    Hockman, EM
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 2003, 78 (02): : 236 - 240
  • [4] Pencil-beam vs. fan-beam Dual-Energy X-Ray Absorptiometry comparisons across 4 systems: Body composition and bone mineral
    Padilla, JMC
    Ioannidou, E
    Wang, J
    Thornton, JC
    Horlick, M
    Gallagher, D
    Heymsfield, SB
    Pierson, RN
    [J]. FASEB JOURNAL, 2003, 17 (05): : A1093 - A1093
  • [5] Occupational dose to the radiographer in dual X-ray absorptiometry: A comparison of pencil-beam and fan-beam systems
    Patel, R
    Blake, GM
    Batchelor, S
    Fogelman, I
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (822): : 539 - 543
  • [6] A Wide Fan-beam Dual-energy X-ray Absorptiometry for Forearm
    Li, Chan
    Li, Liang
    Chen, Zhiqiang
    [J]. 2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [7] Measurement of changes in soft tissue mass and fat mass with weight change: Pencil- versus fan-beam dual-energy X-ray absorptiometry
    Tylavsky, FA
    Fuerst, T
    Nevitt, M
    Dockrell, M
    Wan, JY
    Cauley, J
    Harris, T
    [J]. IN VIVO BODY COMPOSITION STUDIES, 2000, 904 : 94 - 97
  • [8] DUAL X-RAY ABSORPTIOMETRY - A COMPARISON BETWEEN FAN-BEAM AND PENCIL BEAM SCANS
    BLAKE, GM
    PARKER, JC
    BUXTON, FMA
    FOGELMAN, I
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (790): : 902 - 906
  • [9] Cross-calibration of pencil-beam (DPX-NT) and fan-beam (QDR-4500C) dual-energy X-ray absorptiometry for sarcopenia
    Ito, Kenyu
    Tsushita, Kazuyo
    Muramoto, Akiko
    Kanzaki, Hiroki
    Nohara, Takashi
    Shimizu, Hitomi
    Nakazawa, Tomoko
    Harada, Atsushi
    [J]. NAGOYA JOURNAL OF MEDICAL SCIENCE, 2015, 77 (04): : 647 - 652
  • [10] Bone mineral and body composition measurements: Cross-calibration of pencil-beam and fan-beam dual-energy X-ray absorptiometers
    Ellis, KJ
    Shypailo, RJ
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 1998, 13 (10) : 1613 - 1618