Numerical study for the design optimization of a two-phase ejector with R134a refrigerant

被引:0
|
作者
Sunghoon Baek
Simon Song
机构
[1] Hanyang University,Dept. of Mechanical Engineering
[2] Hanyang University,Institute of Nano Science and Technology
关键词
Two-phase ejector; Low-pressure refrigeration cycle; Shape optimization; Entrainment performance;
D O I
暂无
中图分类号
学科分类号
摘要
As the use of refrigeration systems continues to increase around the world, the interest in improving energy efficiency of a refrigeration system is also steadily increasing. A two-phase ejector has received attention as an alternative to improve the performance of a vapor-compression refrigeration cycle. Many theoretical and experimental studies have been performed to improve the efficiency of the ejector refrigeration cycle; however, a numerical study using computational fluid dynamics is required owing to the complexity of the flow physics inside the two-phase ejector. Recently, several numerical studies for the two-phase ejector have been conducted. However, these studies primarily focused on the validation of the numerical codes, and few studies have focused on the effects of the design parameters on the performance and shape optimization. Therefore, in this study, the shape of the two-phase ejector was optimized to maximize the entrainment performance utilizing R134a refrigerant. A validated RANS simulation with an evaporation-condensation model was used for analyzing the flow behaviors inside the ejector. In addition, an evolutionary algorithm (EA) and a micro-genetic algorithm (MGA) were used to determine the optimal design point based on an approximate model. The optimized ejector design showed a 55 % higher entrainment performance than that of the baseline model.
引用
收藏
页码:4231 / 4236
页数:5
相关论文
共 50 条
  • [31] Condensation Heat Transfer and Flow Properties of R134a Refrigerant in Rectangular Minichannel: A Numerical Study
    Li, Wei
    Lyu, Di
    Zhang, Jingzhi
    Sherif, S. A.
    [J]. JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2020, 12 (02)
  • [32] MATERIAL DATA FOR THE NEW REFRIGERANT R134A
    LEIPERTZ, A
    KRAFT, K
    [J]. CHEMIE INGENIEUR TECHNIK, 1994, 66 (03) : 349 - 351
  • [33] Two-phase flow behaviour and pressure drop of R134a in a smooth hairpin
    De Kerpel, K.
    Ameel, B.
    Huisseune, H.
    T'Joen, C.
    Caniere, H.
    De Paepe, M.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (04) : 1179 - 1188
  • [34] ABSORPTION SYSTEM BASED ON THE REFRIGERANT R134A
    BORDE, I
    JELINEK, M
    DALTROPHE, NC
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1995, 18 (06): : 387 - 394
  • [35] Experimental research and simulation of two-phase plume for R134a release and diffusion
    Guo, Xiyan
    Tan, Wei
    Liu, Liyan
    Zhu, Guorui
    [J]. JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2022, 75
  • [36] Experimental study on R-134a refrigeration system using a two-phase ejector as an expansion device
    Chaiwongsa, Praitoon
    Wongwises, Somchai
    [J]. APPLIED THERMAL ENGINEERING, 2008, 28 (5-6) : 467 - 477
  • [37] Shape optimization of a long-tapered R134a ejector mixing chamber
    Sierra-Pallares, Jose
    Garcia del Valle, Javier
    Munoz Paniagua, Jorge
    Garcia, Javier
    Mendez-Bueno, Cesar
    Castro, Francisco
    [J]. ENERGY, 2018, 165 : 422 - 438
  • [38] Area ratio effects to the performance of air-cooled ejector refrigeration cycle with R134a refrigerant
    Yan Jia
    Cai Wenjian
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2012, 53 (01) : 240 - 246
  • [39] Numerical study of condensation heat transfer characteristics of R134a/ R290 and R134a/R1270 refrigerant blends as alternatives to replace R404A
    Zeng, Min-Qiang
    Zou, Lin-Geng
    Peng, Zhao-Rui
    Zhang, Xin-Rong
    Li, Jing
    [J]. APPLIED THERMAL ENGINEERING, 2024, 243
  • [40] CFD modelling of a two-phase closed thermosyphon charged with R134a and R404a
    Fadhl, Bandar
    Wrobel, Luiz C.
    Jouhara, Hussam
    [J]. APPLIED THERMAL ENGINEERING, 2015, 78 : 482 - 490