Determination of cisapride in human plasma by high-performance liquid chromatography with fluorescence detection

被引:0
|
作者
B. Dalmadi Kiss
K. Balogh Nemes
I. Klebovich
机构
[1] EGIS Pharmaceuticals Ltd,Department of Pharmacokinetics
来源
Chromatographia | 2003年 / 57卷
关键词
Column liquid chromatography; Solid-phase extraction; Cisapride; Human plasma; Bioequivalence study;
D O I
暂无
中图分类号
学科分类号
摘要
A new sensitive HPLC-FLD method has been developed and validated for the determination of cisapride in human plasma for a bioequivalence study. A gradient method was used to remove late-eluting plasma components of no interest. The separation was performed on a Li-ChroCART 250-4 Purospher RP-18 (5 μm particle) analytical column fitted with a LiChroCART 4-4 Purospher RP-18 endcapped (5 μm particle) guard column. The excitation and emission wavelengths were 295 and 350 nm during fluorescence detection. The calibration plot was linear in the range of 5–200 ng mL−1. A demethoxy analogue of cisapride was used as internal standard.
引用
收藏
页码:47 / 50
页数:3
相关论文
共 50 条
  • [41] Determination of orbifloxacin in rabbit plasma by high-performance liquid chromatography with fluorescence detection
    García, MA
    Solans, C
    Aramayona, JJ
    Rueda, S
    Bregante, MA
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1999, 37 (06) : 199 - 202
  • [42] DETERMINATION OF PHYSOSTIGMINE IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND FLUORESCENCE DETECTION
    ELSAYED, NM
    RYABIK, JRG
    FERRARIS, S
    WHEELER, CR
    KORTE, DW
    ANALYTICAL BIOCHEMISTRY, 1989, 177 (01) : 207 - 211
  • [43] DETERMINATION OF BENDROFLUMETHIAZIDE IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND FLUORESCENCE DETECTION
    HIKAL, AH
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1986, 9 (13): : 2937 - 2943
  • [44] DETERMINATION OF BETAXOLOL IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION
    CANAL, M
    FLOUVAT, B
    JOURNAL OF CHROMATOGRAPHY, 1985, 342 (01): : 212 - 215
  • [45] Determination of Posaconazole in Plasma/Serum by High-Performance Liquid Chromatography with Fluorescence Detection
    Tang, Peter H.
    SEPARATIONS, 2017, 4 (02)
  • [46] DETERMINATION OF MORPHINE IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION
    SCHNEIDER, JJ
    RAVENSCROFT, PJ
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 497 : 326 - 329
  • [47] DETERMINATION OF PLASMA PSEUDOEPHEDRINE BY FLUORESCENCE DETECTION AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    VEALS, J
    KIM, H
    KORDUBA, C
    CURTIS, D
    DURANTE, E
    LIN, C
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1988, 11 (02): : 417 - 433
  • [48] DETERMINATION OF SALBUTAMOL IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION
    HUTCHINGS, MJ
    PAULL, JD
    MORGAN, DJ
    JOURNAL OF CHROMATOGRAPHY, 1983, 277 (OCT): : 423 - 426
  • [49] DETERMINATION OF PLASMA HOMOCYSTEINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION
    JACOBSEN, DW
    GATAUTIS, VJ
    GREEN, R
    ANALYTICAL BIOCHEMISTRY, 1989, 178 (01) : 208 - 214
  • [50] DETERMINATION OF CISAPRIDE IN PLASMA AND ANIMAL TISSUE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    WOESTENBORGHS, R
    LORREYNE, W
    VANROMPAEY, F
    HEYKANTS, J
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 424 (01): : 195 - 200