ACUVRA: Anion-Exchange Chromatography UV-Ratio Analysis—A QC-Friendly Method for Monitoring Adeno-Associated Virus Empty Capsid Content To Support Process Development and GMP Release Testing

被引:0
|
作者
Ruth Frenkel
Dana Tribby
Boris Boumajny
Nicholas Larson
Matthew Sampson
Christopher Barney
Svetlana Bergelson
Zoran Sosic
Bernice Yeung
机构
[1] Biogen Inc,Department of Gene Therapy Analytical Development
[2] Biogen Inc,Department of Quality Control
来源
关键词
AAV; Empty capsids; Method validation; Quality control; Anion-exchange chromatography;
D O I
暂无
中图分类号
学科分类号
摘要
The genome content of adeno-associated virus (AAV) vectors is critical to the safety and potency of AAV-based gene therapy products. Empty capsids are considered a product-related impurity and a critical quality attribute (CQA) of the drug product, thus requiring characterization throughout the production process to demonstrate they are controlled to acceptable levels in the final drug product. Anion exchange chromatography has been used to achieve separation between empty and full capsids, but requires method development and gradient optimization for different serotypes and formulations. Here, we describe an alternative approach to quantitation that does not rely on achieving separation between empty and full capsids, but instead uses the well-established relationship between absorbance at UV A260/A280 and relation to DNA/protein content, in combination with anion-exchange chromatography to allow one to calculate the relative proportion of empty and full capsids in AAV samples from a single peak. We call this approach ACUVRA: Anion-exchange Chromatography UV-Ratio Analysis, and show the applicability of the method through a case study with recombinant AAV2 (rAAV2) process intermediates and drug substance. Method qualification and GMP validation in a quality control (QC) laboratory results show that ACUVRA is a fit-for-purpose method for process development support and characterization, while also being a QC-friendly option for GMP release testing at all stages of clinical development.
引用
收藏
相关论文
共 4 条
  • [1] ACUVRA: Anion-Exchange Chromatography UV-Ratio Analysis-A QC-Friendly Method for Monitoring Adeno-Associated Virus Empty Capsid Content To Support Process Development and GMP Release Testing
    Frenkel, Ruth
    Tribby, Dana
    Boumajny, Boris
    Larson, Nicholas
    Sampson, Matthew
    Barney, Christopher
    Bergelson, Svetlana
    Sosic, Zoran
    Yeung, Bernice
    AAPS JOURNAL, 2022, 25 (01):
  • [2] An Anion-Exchange Chromatography Method for Monitoring Empty Capsid Content in Adeno-Associated Virus Serotype AAV8
    Yang, Hua
    Koza, Stephan M.
    Chen, Weibin
    LC GC NORTH AMERICA, 2020, 38 (06) : 369 - 370
  • [3] An Anion-Exchange Chromatography Method for Monitoring Empty Capsid Content in Adeno-Associated Virus Serotype AAV8
    Yang, Hua
    Koza, Stephan M.
    Chen, Weibin
    LC GC EUROPE, 2020, 33 (07) : 368 - 369
  • [4] Development and Validation of an Anion Exchange High-Performance Liquid Chromatography Method for Analysis of Empty Capsids and Capsids Encapsidating Genetic Material in a Purified Preparation of Recombinant Adeno-Associated Virus Serotype 5
    Joshi, Pranav R. H.
    Bernier, Alice
    Chahal, Parminder S.
    Kamen, Amine
    HUMAN GENE THERAPY, 2021, 32 (21-22) : 1390 - 1402