An Anion-Exchange Chromatography Method for Monitoring Empty Capsid Content in Adeno-Associated Virus Serotype AAV8

被引:0
|
作者
Yang, Hua [1 ]
Koza, Stephan M. [1 ]
Chen, Weibin [1 ]
机构
[1] Waters Corp, 34 Maple St, Milford, MA 01757 USA
关键词
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The single-stranded DNA (ssDNA) content of AAV capsids in AAV-based gene therapy preparations impacts the efficacy of this treatment modality. We demonstrate that AAV8 capsids without and with full length ssDNA can be separated and their relative abundances determined on a WatersT Protein-Pak (TM) Hi Res Q strong anion-exchange column.
引用
收藏
页码:368 / 369
页数:2
相关论文
共 50 条
  • [1] An Anion-Exchange Chromatography Method for Monitoring Empty Capsid Content in Adeno-Associated Virus Serotype AAV8
    Yang, Hua
    Koza, Stephan M.
    Chen, Weibin
    LC GC NORTH AMERICA, 2020, 38 (06) : 369 - 370
  • [2] Adeno-associated virus serotype 8 (AAV8)-mediated shRNA delivery in vivo
    Chen, Yingwei
    Yokota, Takanori
    Kubodera, Takayuki
    Ohnishi, Iichirou
    Li, Yi
    Kazutaka, Nishina
    Hirai, Yukihiko
    Shimada, Takashi
    Mizusawa, Hidehiro
    JOURNAL OF GENE MEDICINE, 2006, 8 (12): : 1448 - 1448
  • [3] Kinetics of Adeno-Associated Virus Serotype 2 (AAV2) and AAV8 Capsid Antigen Presentation In Vivo Are Identical
    He, Yi
    Weinberg, Marc S.
    Hirsch, Matt
    Johnson, Mark C.
    Tisch, Roland
    Samulski, R. Jude
    Li, Chengwen
    HUMAN GENE THERAPY, 2013, 24 (05) : 545 - 553
  • [4] ACUVRA: Anion-Exchange Chromatography UV-Ratio Analysis—A QC-Friendly Method for Monitoring Adeno-Associated Virus Empty Capsid Content To Support Process Development and GMP Release Testing
    Ruth Frenkel
    Dana Tribby
    Boris Boumajny
    Nicholas Larson
    Matthew Sampson
    Christopher Barney
    Svetlana Bergelson
    Zoran Sosic
    Bernice Yeung
    The AAPS Journal, 25
  • [5] Novel anion exchange membrane chromatography method for the separation of empty and full adeno-associated virus
    Hejmowski, Adam L.
    Boenning, Kurt
    Huato, Julio
    Kavara, Aydin
    Schofield, Mark
    BIOTECHNOLOGY JOURNAL, 2022, 17 (02)
  • [6] ACUVRA: Anion-Exchange Chromatography UV-Ratio Analysis-A QC-Friendly Method for Monitoring Adeno-Associated Virus Empty Capsid Content To Support Process Development and GMP Release Testing
    Frenkel, Ruth
    Tribby, Dana
    Boumajny, Boris
    Larson, Nicholas
    Sampson, Matthew
    Barney, Christopher
    Bergelson, Svetlana
    Sosic, Zoran
    Yeung, Bernice
    AAPS JOURNAL, 2022, 25 (01):
  • [7] Empty and Full Separation of Adeno-Associated Virus Vectors by Anion Exchange Membrane Chromatography
    Kavara, Aydin
    Hejmowski, Adam
    Boenning, Kurt
    Huato, Julio
    Schofield, Mark
    MOLECULAR THERAPY, 2021, 29 (04) : 394 - 394
  • [8] EMPTY AND FULL SEPARATION OF ADENO-ASSOCIATED VIRUS VECTORS BY ANION EXCHANGE MEMBRANE CHROMATOGRAPHY
    Huato, J.
    Schofield, M.
    Boenning, K.
    Kavara, A.
    Hejmowski, A.
    CYTOTHERAPY, 2021, 23 (05) : S155 - S155
  • [9] Adeno-associated viral capsid stability on anion exchange chromatography column and its impact on empty and full capsid separation
    Khanal, Ohnmar
    Kumar, Vijesh
    Jin, Mi
    MOLECULAR THERAPY METHODS & CLINICAL DEVELOPMENT, 2023, 31
  • [10] Separation of full and empty adeno-associated virus capsids by anion-exchange chromatography using choline-type salts
    Kurth, Sam
    Li, Tianyu
    Hausker, Alana
    Evans, William E.
    Dabre, Romain
    Mueller, Egbert
    Kervinen, Jukka
    ANALYTICAL BIOCHEMISTRY, 2024, 686