Inter-laboratory automation of the in vitro micronucleus assay using imaging flow cytometry and deep learning

被引:0
|
作者
John W. Wills
Jatin R. Verma
Benjamin J. Rees
Danielle S. G. Harte
Qiellor Haxhiraj
Claire M. Barnes
Rachel Barnes
Matthew A. Rodrigues
Minh Doan
Andrew Filby
Rachel E. Hewitt
Catherine A. Thornton
James G. Cronin
Julia D. Kenny
Ruby Buckley
Anthony M. Lynch
Anne E. Carpenter
Huw D. Summers
George E. Johnson
Paul Rees
机构
[1] Swansea University,College of Engineering
[2] Cambridge University,Department of Veterinary Medicine
[3] Swansea University,Swansea University Medical School
[4] Luminex Corporation,Amnis Flow Cytometry
[5] GlaxoSmithKline,Bioimaging Analytics
[6] Newcastle University,Faculty of Medical Sciences
[7] GlaxoSmithKline Research and Development Platform,Imaging Platform
[8] Broad Institute of MIT and Harvard,undefined
来源
Archives of Toxicology | 2021年 / 95卷
关键词
Micronucleus test; Genetic toxicology; Compound screening; Machine learning; High throughput; Image analysis.;
D O I
暂无
中图分类号
学科分类号
摘要
The in vitro micronucleus assay is a globally significant method for DNA damage quantification used for regulatory compound safety testing in addition to inter-individual monitoring of environmental, lifestyle and occupational factors. However, it relies on time-consuming and user-subjective manual scoring. Here we show that imaging flow cytometry and deep learning image classification represents a capable platform for automated, inter-laboratory operation. Images were captured for the cytokinesis-block micronucleus (CBMN) assay across three laboratories using methyl methanesulphonate (1.25–5.0 μg/mL) and/or carbendazim (0.8–1.6 μg/mL) exposures to TK6 cells. Human-scored image sets were assembled and used to train and test the classification abilities of the “DeepFlow” neural network in both intra- and inter-laboratory contexts. Harnessing image diversity across laboratories yielded a network able to score unseen data from an entirely new laboratory without any user configuration. Image classification accuracies of 98%, 95%, 82% and 85% were achieved for ‘mononucleates’, ‘binucleates’, ‘mononucleates with MN’ and ‘binucleates with MN’, respectively. Successful classifications of ‘trinucleates’ (90%) and ‘tetranucleates’ (88%) in addition to ‘other or unscorable’ phenotypes (96%) were also achieved. Attempts to classify extremely rare, tri- and tetranucleated cells with micronuclei into their own categories were less successful (≤ 57%). Benchmark dose analyses of human or automatically scored micronucleus frequency data yielded quantitation of the same equipotent concentration regardless of scoring method. We conclude that this automated approach offers significant potential to broaden the practical utility of the CBMN method across industry, research and clinical domains. We share our strategy using openly-accessible frameworks.
引用
收藏
页码:3101 / 3115
页数:14
相关论文
共 50 条
  • [41] An inter-laboratory comparison of PNH clone detection by high-sensitivity flow cytometry in a Russian cohort
    Sipol, Alexandra A.
    Babenko, Elena V.
    Borisov, Vyacheslav I.
    Naumova, Elena V.
    Boyakova, Elena V.
    Yakunin, Dimitry I.
    Glazanova, Tatyana V.
    Chubukina, Zhanna V.
    Pronkina, Natalya V.
    Popov, Alexander M.
    Saveliev, Leonid I.
    Lugovskaya, Svetlana A.
    Lisukov, Igor A.
    Kulagin, Alexander D.
    Illingworth, Andrea J.
    HEMATOLOGY, 2015, 20 (01) : 31 - 38
  • [42] In vitro micronucleus assay for the analysis of total particulate matter in cigarette smoke: Comparison of flow cytometry and laser scanning cytometry with microscopy
    Yao, Jianhua
    Gao, Qian
    Mi, Qili
    Li, Xuemei
    Miao, Mingming
    Cheng, Peng
    Luo, Ying
    MUTATION RESEARCH-GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS, 2013, 755 (02) : 120 - 125
  • [43] Dramatically Increasing the Capacity of Genotoxicity Testing: Automating a Flow Cytometry-Based In Vitro Micronucleus Assay
    Liu, Z.
    Bryce, S.
    Bemis, J.
    Luu, Y. K.
    ENVIRONMENTAL AND MOLECULAR MUTAGENESIS, 2012, 53 : S48 - S48
  • [44] In Vivo Rat Pig-a Mutation Assessment by Flow Cytometry: Inter-Laboratory Comparison of ENU Treated Rats
    Fiedler, R. D.
    Gunther, W. C.
    Thiffeault, C. J.
    Shutsky, T. J.
    Phonethepswath, S.
    Franklin, D.
    Raja, S.
    Dertinger, S. D.
    ENVIRONMENTAL AND MOLECULAR MUTAGENESIS, 2009, 50 (07) : 574 - 574
  • [45] Centrally-determined standardization of flow cytometry methods reduces inter-laboratory variation in a prospective multicenter study
    Westera, L.
    van Viegen, T.
    Jeyarajah, J.
    Azad, A.
    Bilsborough, J.
    van den Brink, G.
    Danese, S.
    D'Haens, G.
    Eckmann, L.
    Faubion, W.
    Korf, H.
    McGovern, D.
    Panes, J.
    Salas, A.
    Sandborn, W.
    Silverberg, M.
    Smith, M.
    Vermeire, S.
    Vetrano, S.
    Shackelton, L.
    Stitt, L.
    Jairath, V.
    Levesque, B.
    Spencer, D.
    Feagan, B.
    Vande Casteele, N.
    JOURNAL OF CROHNS & COLITIS, 2017, 11 : S103 - S103
  • [46] CENTRALLY-DETERMINED STANDARDIZATION OF FLOW CYTOMETRY METHODS REDUCES INTER-LABORATORY VARIATION IN A PROSPECTIVE MULTICENTER STUDY
    Westera, Liset
    van Viegen, Tanja
    Jeyarajah, Jenny
    Azad, Azar
    Bilsborough, Janine
    van den Brink, Gijs
    Danese, Silvio
    D'Haens, Geert R.
    Eckmann, Lars
    Faubion, William
    Korf, Hannelie
    McGovern, Dermot
    Panes, Julian
    Salas, Azucena
    Sandborn, William J.
    Silverberg, Mark S.
    Smith, Michelle I.
    Vermeire, Severine
    Vetrano, Stefania
    Shackelton, Lisa
    Stitt, Larry
    Jairath, Vipul
    Levesque, Barrett
    Spencer, David
    Feagan, Brian G.
    Casteele, Niels Vande
    GASTROENTEROLOGY, 2017, 152 (05) : S772 - S772
  • [47] In vitro testing of embryotoxicity using the embryonic stem cell test:: An inter-laboratory comparison
    Scholz, G
    Pohl, I
    Seiler, A
    Bremer, S
    Moldenhauer, F
    Holzhütter, HG
    Spielmann, H
    NAUNYN-SCHMIEDEBERGS ARCHIVES OF PHARMACOLOGY, 1998, 357 (04) : R155 - R155
  • [48] Comparison of Microscopy-Based, Conventional Flow Cytometry and Imaging Flow Cytometry Methods for In Vitro Micronucleus Test in TK6 Cells
    Xie, H.
    Rodrigues, M. A.
    Kulkarni, R.
    INTERNATIONAL JOURNAL OF TOXICOLOGY, 2020, 39 (01) : 65 - 65
  • [49] Inter-laboratory evaluation of the bioluminescent Salmonella reverse mutation assay using 10 model chemicals
    Ackerman, Joel
    Sharma, Rahul
    Hitchcock, Jonathan
    Hayashi, Toshiaki
    Nagai, Yoshikazu
    Li, Shuanglian
    Lu, Shuyan
    Miret, Juan
    Tang, Kim
    Spence, Fiona
    Aubrecht, Jiri
    MUTAGENESIS, 2009, 24 (05) : 433 - 438
  • [50] Miniaturized flow cytometry-based in vitro primary human lymphocyte micronucleus assay-validation study
    Lukamowicz-Rajska, Magdalena
    Kirsch-Volders, Micheline
    Suter, Willi
    Martus, Hansjoerg
    Elhajouji, Azeddine
    ENVIRONMENTAL AND MOLECULAR MUTAGENESIS, 2012, 53 (04) : 260 - 270