Experimental study on a centrifugal pump with an open impeller during startup period

被引:0
|
作者
Yuliang Zhang
Zuchao Zhu
Yingzi Jin
Baoling Cui
Yi Li
Huashu Dou
机构
[1] Zhejiang University,The State Key Lab of Fluid Power Transmission and Control
[2] Zhejiang Sci-Tech University,The Province Key Lab of Fluid Transmission Technology
来源
Journal of Thermal Science | 2013年 / 22卷
关键词
centrifugal pump; open impeller; startup; experimental study; transient behavior;
D O I
暂无
中图分类号
学科分类号
摘要
Transient performance of fluid machinery during transient operating periods, such as startup and stopping, has been drawn more attentions recently due to the growing engineering needs. In this paper, the transient behavior of a prototype centrifugal pump with an open impeller during rapid startup period is studied experimentally. The variations of the rotational speed, flow rate, head, and shaft power during rapid startup period are recorded in experiments at different discharge valve openings. In addition, the non-dimensional flow rate and head are also used to analyze the transient behavior. The research result shows that the rise characteristic of the rotational speed is not basically changed by working points, while mainly depends on the startup characteristics of the driving motor. Compared with the rapid rise of the rotational speed, the flow rate rises slowly in the initial stage of startup. Moreover, the flow rate lags behind the rotational speed to rise to final stable value, and the delay becomes more severe with the increase of the discharge valve opening. The shaft power impact phenomenon generally exists in the process of startup. The non-dimensional analysis shows that the non-dimensional head is very high at the very beginning of startup, and quickly falls to the minimum, then gradually rises to final stable value, while the non-dimensional flow rate always shows the rise tendency during whole startup period. In conclusion, it is found from the non-dimensional results that the quasi-steady analysis is unable to accurately assess the transient flow during startup period.
引用
收藏
页码:1 / 6
页数:5
相关论文
共 50 条
  • [31] The flow of wheat straw suspensions in an open-impeller centrifugal pump
    Vaezi, Mahdi
    Kumar, Amit
    BIOMASS & BIOENERGY, 2014, 69 : 106 - 123
  • [32] Experimental Study on Transient Startup Characteristics of a Super Low Specific Speed Centrifugal Pump
    Wang, Yong
    Xie, Lei
    Chen, Jie
    Liu, Hou-lin
    Luo, Kaikai
    Zhang, Zi-long
    Cao, Man-hui
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 2019, 52 (09) : 743 - 750
  • [33] Research on Performance of Centrifugal Pump with Different-type Open Impeller
    Cui Baoling
    Chen Desheng
    Wang Canfei
    Zhu Zuchao
    Jin Yingzi
    Jin Yuzhen
    JOURNAL OF THERMAL SCIENCE, 2013, 22 (06) : 586 - 591
  • [34] Research on Performance of Centrifugal Pump with Different-type Open Impeller
    CUI Baoling
    CHEN Desheng
    WANG Canfei
    ZHU Zuchao
    JIN Yingzi
    JIN Yuzhen
    Journal of Thermal Science, 2013, 22 (06) : 586 - 591
  • [35] Research on performance of centrifugal pump with different-type open impeller
    Baoling Cui
    Desheng Chen
    Canfei Wang
    Zuchao Zhu
    Yingzi Jin
    Yuzhen Jin
    Journal of Thermal Science, 2013, 22 : 586 - 591
  • [36] EXPERIMENTAL STUDY OF TWO-PHASE AIR/WATER FLOW IN A CENTRIFUGAL PUMP WORKING WITH A CLOSED OR A SEMI-OPEN IMPELLER
    Mansour, Michael
    Wunderlich, Bernd
    Thevenin, Dominique
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, 2018, VOL 9, 2018,
  • [37] Fluid-structure interaction study of a mixed-flow pump impeller during startup
    Li, Wei
    Ji, Leilei
    Shi, Weidong
    Zhou, Ling
    Jiang, Xiaoping
    Zhang, Yang
    ENGINEERING COMPUTATIONS, 2018, 35 (01) : 18 - 34
  • [38] Impeller radial force evolution in a large double-suction centrifugal pump during startup at the shut-off condition
    Zou, Zhichao
    Wang, Fujun
    Yao, Zhifeng
    Tao, Ran
    Xiao, Ruofu
    Li, Huaicheng
    NUCLEAR ENGINEERING AND DESIGN, 2016, 310 : 410 - 417
  • [39] Analysis and experimental of centrifugal pump noise based on outlet width of impeller
    Liu, Houlin
    Ding, Jian
    Tan, Minggao
    Cui, Jianbao
    Wang, Yong
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2013, 29 (16): : 66 - 73
  • [40] EXPERIMENTAL AND NUMERICAL INVESTIGATION OF RADIAL FORCES ACTING ON CENTRIFUGAL PUMP IMPELLER
    Karaskiewicz, Krzysztof
    Szlaga, Marek
    ARCHIVE OF MECHANICAL ENGINEERING, 2014, 61 (03) : 445 - 454