Retention Characteristics of Peptides in RP-LC: Peptide Retention Prediction

被引:0
|
作者
Valeri I. Babushok
Igor G. Zenkevich
机构
[1] KTC Consulting,
[2] Chemical Research Institute of St. Petersburg State University,undefined
来源
Chromatographia | 2010年 / 72卷
关键词
Reversed phase-liquid chromatography; Retention indices; Retention prediction; Peptides; Review;
D O I
暂无
中图分类号
学科分类号
摘要
A review of recent results of the use of chromatographic retention data in peptide identification and in the development of procedures for peptide retention prediction is presented. In recent years, reversed phase LC (RP-LC) has become an important tool in the separation of peptides in MS analysis. A challenging problem in a further expansion of RP-LC applications is the use of already available retention information for the identification purposes simultaneously with MS–MS identification. This overview focuses on the retention characteristics suggested in LC. We will discuss the application of the retention index concept in LC, which is widely used in GC to characterize retention of organic compounds. The use of retention indices as retention characteristics of analytes in LC was first suggested at the end of 1970s, however the application of retention indices is still somewhat rare today. There are several reasons for this. One is the relatively high sensitivity and variability of retention indices to the change of parameters of chromatographic systems. Another is the chemical restrictions in the search of the universal set of reference compounds suitable for retention scaling. Several methods were suggested for the prediction of the retention times of peptides. A frequently used approach is based on the additivity scheme and calculation of the elution time through the summation of retention coefficients of amino acids constituting the peptide. Such an approach allows fairly accurate predictions of the retention time of peptides made up of not more then 15–20 amino acid residues. Additional correction factors were suggested to improve predictions including corrections for the peptide length, peptide hydrophobicity, sequence of amino acids, etc. Suggested procedures are discussed in detail. Application of predicted retention times in the identification of peptides is considered. Current status of LC retention data collections is presented.
引用
收藏
页码:781 / 797
页数:16
相关论文
共 50 条
  • [41] Estimation of Nonlinear Adsorption Isotherms in Gradient Elution RP-LC of Peptides in the Presence of an Adsorbing Additive
    Asberg, Dennis
    Lesko, Marek
    Leek, Tomas
    Samuelsson, Jorgen
    Kaczmarski, Krzysztof
    Fornstedt, Torgny
    CHROMATOGRAPHIA, 2017, 80 (06) : 961 - 966
  • [42] Duplicating the Retention of Cationic Analytes Obtained with Ammonium Formate Mobile Phases when Switching to UV Transparent Mobile Phase Additives in RP-LC
    Loeser, Eric
    Babiak, Stanislaw
    CHROMATOGRAPHIA, 2009, 70 (9-10) : 1311 - 1319
  • [43] RP-LC x RP-LC analysis of a tryptic digest using a combination of totally porous and partially porous stationary phases
    Mondello, Luigi
    Donato, Paola
    Cacciola, Francesco
    Fanali, Chiara
    Dugo, Paola
    JOURNAL OF SEPARATION SCIENCE, 2010, 33 (10) : 1454 - 1461
  • [44] PREDICTION OF LC RETENTION OF STEROIDS USING SOLVATOCHROMIC PARAMETERS
    BARRON, D
    PASCUAL, JA
    SEGURA, J
    BARBOSA, J
    CHROMATOGRAPHIA, 1995, 41 (9-10) : 573 - 580
  • [45] Prediction of retention characteristics of heterocyclic compounds
    Nesmerak, Karel
    Toropov, Andrey A.
    Toropova, Alla P.
    Yildiz, Ilkay
    Yalcin, Ismail
    Brozikova, Marketa
    Klimesova, Vera
    Waisser, Karel
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (30) : 9185 - 9189
  • [46] Prediction of retention characteristics of heterocyclic compounds
    Karel Nesměrák
    Andrey A. Toropov
    Alla P. Toropova
    Ilkay Yildiz
    Ismail Yalcin
    Marketa Brozikova
    Vera Klimešová
    Karel Waisser
    Analytical and Bioanalytical Chemistry, 2015, 407 : 9185 - 9189
  • [47] MOLECULAR DEFINITION OF THE RETENTION PARAMETERS OF PEPTIDES SEPARATED BY RP-HPLC
    AGUILAR, MI
    RICHARDS, KL
    ROUND, AJ
    HEARN, MTW
    PEPTIDE RESEARCH, 1994, 7 (04): : 207 - 217
  • [48] Sample conditions to avoid pH distortion in RP-LC
    Samuelsson, Jorgen
    Forssen, Patrik
    Fornstedt, Torgny
    JOURNAL OF SEPARATION SCIENCE, 2013, 36 (23) : 3769 - 3775
  • [49] RP-LC Determination of Residual Monomers in Polycarboxylate Superplasticizers
    Lei, Jiaheng
    Du, Xiaodi
    Zhang, Anfu
    Wu, Hui
    CHROMATOGRAPHIA, 2011, 73 (11-12) : 1131 - 1136
  • [50] RP-LC Determination of Residual Monomers in Polycarboxylate Superplasticizers
    Jiaheng Lei
    Xiaodi Du
    Anfu Zhang
    Hui Wu
    Chromatographia, 2011, 73 : 1131 - 1136