Effect of groundwater chemistry and temperature on swelling and microstructural properties of sand–bentonite for barriers of radioactive waste repositories

被引:0
|
作者
Asmaa Shehata
Mamadou Fall
Christian Detellier
Mohammed Alzamel
机构
[1] University of Ottawa,Department of Civil Engineering
[2] University of Ottawa,Department of Chemistry and Biomolecular Sciences and Center for Catalysis Research and Innovation
关键词
Deep geological repository; Nuclear waste; Bentonite; Engineered barrier; Groundwater; Swelling;
D O I
暂无
中图分类号
学科分类号
摘要
Compacted bentonite–sand mixtures are commonly considered as the key materials for the construction of engineered barrier systems (EBSs) in deep geological repositories (DGRs) in Canada and other countries. These bentonite-based barriers can be simultaneously exposed to a wide range of chemical and thermal (nuclear waste heat decay) conditions of underground water. Thus, an understanding of the effects of groundwater chemistry and temperature and their interactions on the changes in the swelling properties as well as the microstructure of bentonite-based barriers is essential for assessing the durability and safety of an EBS in a DGR. This study experimentally investigates the impact of a Canadian deep underground water chemistry (C; total dissolved solids up to 300 g/L), temperature (T; 23 °C, 40 °C, and 80 °C), and the coupled effects of C and T on the swelling properties and microstructure of bentonite–sand barrier mixtures (30 to 70% by weight). The results show that the groundwater chemistry of southwestern Ontario (Canada) has a significant impact on the swelling characteristics of the examined bentonite–sand material. The swelling ability significantly decreases with respect to the groundwater chemistry. The mineralogical composition of the bentonite changes. Most of the Na-montmorillonite is mainly transformed to Ca-montmorillonite and traces of illite with a lower swelling capacity when the bentonite–sand barrier material is exposed mixed to saline water solutions. The temperature (alone) has a limited effect. However, the temperature–groundwater chemistry interactions significantly affect the swelling capacity of the studied bentonite–sand material. Future safety assessments and the final engineering design of engineered barriers for DGRs in Ontario should take into consideration the possibility of the long-term deterioration of bentonite–sand barriers from chemical attacks and/or thermochemical attacks induced by the high salinity of the groundwater and by simultaneous impact of the chemistry of the groundwater and the heat generated by the nuclear wastes, respectively.
引用
收藏
页码:1857 / 1873
页数:16
相关论文
共 21 条
  • [21] The Effect of Basalt Fiber on Mechanical, Microstructural, and High-Temperature Properties of Fly Ash-Based and Basalt Powder Waste-Filled Sustainable Geopolymer Mortar
    Ziada, Mahmoud
    Erdem, Savas
    Tammam, Yosra
    Kara, Serenay
    Gonzalez Lezcano, Roberto Alonso
    [J]. SUSTAINABILITY, 2021, 13 (22)