Tumour blood flow and partition coefficients: Correlation with grade of cerebral gliomas using xenon-enhanced computed tomography

被引:0
|
作者
Našel C. [1 ]
Rössler K. [2 ]
Heimberger K. [1 ]
Görzer H. [1 ]
Lassmann H. [3 ]
Schindler E. [1 ]
机构
[1] Department of Radiology, University of Vienna, AKH Wien, A-1090 Vienna
[2] Department of Neurosurgery, University of Vienna, Vienna
[3] Res. U. for Exp. Neuropathology, Austrian Academy of Sciences, Vienna
关键词
Astrocytoma; Brain-blood partition coefficient; Xenon CT;
D O I
10.1007/s002340050481
中图分类号
学科分类号
摘要
It is possible to underestimate the grade of nonenhancing cerebral tumours on conventional contrast-enhanced MRI or CT. Differentiation of high- and low-grade gliomas by measurement of the brain-blood partition coefficient lambda (Tλ) with Xe-enhanced CT (XeCT) has been reported. We assessed the practical applications of XeCT in suspected low-grade astrocytomas. We examined 15 patients with tumours which showed no contrast enhancement on conventional MRI and CT, using XeCT. Tumour blood flow (TBF) and Tλ,were calculated. Fourteen patients underwent surgery, one patient had a biopsy, We recognised three histological groups. While Tλ differed significantly between them, TBF did not. Group 1 contained grade II-III astrocytomas and Tλ was 0.77; group 2 contained grade I-II astrocytomas with Tλ 1.14, and group 3 four oligodendrogliomas in which a Tλ of 1.50 was found.
引用
收藏
页码:627 / 632
页数:5
相关论文
共 50 条
  • [31] Dynamic assessment of paranasal sinus ventilation using xenon-enhanced computed tomography
    Marcucci, C
    Leopold, DA
    Cullen, M
    Zinreich, SJ
    Simon, BA
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2001, 110 (10): : 968 - 975
  • [32] XENON-ENHANCED COMPUTED-TOMOGRAPHY COMPARED WITH [C-14] IODOANTIPYRINE FOR NORMAL AND LOW CEREBRAL BLOOD-FLOW STATES IN BABOONS
    WOLFSON, SK
    CLARK, J
    GREENBERG, JH
    GUR, D
    YONAS, H
    BRENNER, RP
    COOK, EE
    LORDEON, PA
    STROKE, 1990, 21 (05) : 751 - 757
  • [33] CEREBRAL BLOOD-FLOW - MEASUREMENT WITH XENON-ENHANCED DYNAMIC HELICAL CT
    NAMBU, K
    SUZUKI, R
    HIRAKAWA, K
    RADIOLOGY, 1995, 195 (01) : 53 - 57
  • [34] ADVERSE REACTIONS TO XENON-ENHANCED CT CEREBRAL BLOOD-FLOW DETERMINATION
    LATCHAW, RE
    YONAS, H
    PENTHENY, SL
    GUR, D
    RADIOLOGY, 1987, 163 (01) : 251 - 254
  • [35] DISCREPANCY OF XENON CONCENTRATIONS BETWEEN END-TIDAL AND BLOOD COLLECTION METHODS IN XENON-ENHANCED COMPUTED TOMOGRAPHIC MEASUREMENT OF CEREBRAL BLOOD-FLOW
    SHIMODA, M
    ODA, S
    SATO, O
    KAWAMATA, F
    YAMAMOTO, M
    NEURORADIOLOGY, 1992, 35 (01) : 66 - 68
  • [36] COMPARISON OF SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY WITH [I-123] IODOAMPHETAMINE AND XENON-ENHANCED COMPUTED-TOMOGRAPHY FOR ASSESSING REGIONAL CEREBRAL BLOOD-FLOW
    HELLMAN, RS
    COLLIER, BD
    TIKOFSKY, RS
    KILGORE, DP
    DANIELS, DL
    HAUGHTON, VM
    WALSH, PR
    CUSICK, JF
    SAXENA, VK
    PALMER, DW
    ISITMAN, AT
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1986, 6 (06): : 747 - 755
  • [37] Regional cerebral blood flow in peritumoral brain edema during dexamethasone treatment: A xenon-enhanced computed tomographic study
    Behrens, PF
    Ostertag, CB
    Warnke, PC
    NEUROSURGERY, 1998, 43 (02) : 235 - 240
  • [38] XENON-ENHANCED COMPUTED TOMOGRAPHIC CEREBRAL BLOOD-FLOW (XECTCBF) MEASUREMENT MODIFIED FOR USE IN VENTILATOR DEPENDENT INFANTS
    EMERY, JR
    PEABODY, JL
    ASSAAD, AN
    ASHWAL, S
    THOMPSON, JR
    CLINICAL RESEARCH, 1988, 36 (01): : A221 - A221
  • [40] IMPROVED METHODS FOR MAPPING LOCAL CEREBRAL BLOOD-FLOW BY 27-PERCENT TO 30-PERCENT XENON-ENHANCED COMPUTED-TOMOGRAPHY
    MEYER, JS
    SHINOHARA, T
    IMAI, A
    KOBARI, M
    SAKAI, F
    HATA, T
    ORAVEZ, WT
    SOLOMON, E
    TIMPE, G
    ANNALS OF NEUROLOGY, 1987, 22 (01) : 158 - 158