We present a systematic study of the time and band-resolved scintillation in xenon-based time projection chambers (TPCs), performed simultaneously for the primary (S1) and secondary (S2) components in a small, purity-controlled, setup. We explore a range of conditions of general academic interest, focusing on those of relevance to contemporary TPCs: pressure range 1–10 bar, pressure-reduced electric fields of 0–100 V/cm/bar in the drift region (S1) and up to the proportional scintillation regime in the multiplication region (S2), and wavelength bands 145–250/250–400/400–600 nm, for both α\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\alpha $$\end{document} and β\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\beta $$\end{document} particles. Attention is paid to the possibility of non-conventional scintillation mechanisms such as the 3rd continuum emission, recombination light from β\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\beta $$\end{document}-electrons at high pressure (for S1), emission from high-lying excited states and neutral bremsstrahlung (for S2). Time constants and, specially, scintillation yields have been obtained as a function of electric field and pressure, the latter aided by Geant4 simulations.
引用
收藏
相关论文
共 50 条
  • [21] Discrimination of electronic recoils from nuclear recoils in two-phase xenon time projection chambers
    Akerib, D. S.
    Alsum, S.
    Araujo, H. M.
    Bai, X.
    Balajthy, J.
    Baxter, A.
    Bernard, E. P.
    Bernstein, A.
    Biesiadzinski, T. P.
    Boulton, E. M.
    Boxer, B.
    Bras, P.
    Burdin, S.
    Byram, D.
    Carmona-Benitez, M. C.
    Chan, C.
    Cutter, J. E.
    de Viveiros, L.
    Druszkiewicz, E.
    Fan, A.
    Fiorucci, S.
    Gaitskell, R. J.
    Ghag, C.
    Gilchriese, M. G. D.
    Gwilliam, C.
    Hall, C. R.
    Haselschwardt, S. J.
    Hertel, S. A.
    Hogan, D. P.
    Horn, M.
    Huang, D. Q.
    Ignarra, C. M.
    Jacobsen, R. G.
    Jahangir, O.
    Ji, W.
    Kamdin, K.
    Kazkaz, K.
    Khaitan, D.
    Korolkova, E., V
    Kravitz, S.
    Kudryavtsev, V. A.
    Leason, E.
    Lenardo, B. G.
    Lesko, K. T.
    Liao, J.
    Lin, J.
    Lindote, A.
    Lopes, M., I
    Manalaysay, A.
    Mannino, R. L.
    PHYSICAL REVIEW D, 2020, 102 (11)
  • [22] A 83Krm source for use in low-background liquid Xenon time projection chambers
    Kastens, L. W.
    Bedikian, S.
    Cahn, S. B.
    Manzur, A.
    McKinsey, D. N.
    JOURNAL OF INSTRUMENTATION, 2010, 5
  • [23] A gating grid driver for time projection chambers
    Tangwancharoen, S.
    Lynch, W. G.
    Barney, J.
    Estee, J.
    Shane, R.
    Tsang, M. B.
    Zhang, Y.
    Isobe, T.
    Kurata-Nishimura, M.
    Murakami, T.
    Xiao, Z. G.
    Zhang, Y. F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 853 : 44 - 52
  • [24] ELECTRONICS FOR A XENON TIME PROJECTION CHAMBER.
    Iqbal, M.Z.
    O'Callaghan, B.M.G.
    Wong, H.T.-K.
    Nuclear instruments and methods in physics research, 1988, A263 (2-3): : 387 - 391
  • [25] Ion feedback suppression in time projection chambers
    Sauli, F
    Ropelewski, L
    Everaerts, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 560 (02): : 269 - 277
  • [26] Tests of Micro-Pattern Gaseous Detectors for active target time projection chambers in nuclear physics
    Pancin, J.
    Damoy, S.
    Loureiro, D. Perez
    Chambert, V.
    Dorangeville, F.
    Druillole, F.
    Grinyer, G. F.
    Lermitage, A.
    Maroni, A.
    Noel, G.
    Porte, C.
    Roger, T.
    Rosier, P.
    Suen, L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 735 : 532 - 540
  • [27] Offline tagging of radon-induced backgrounds in XENON1T and applicability to other liquid xenon time projection chambers
    Aprile, E.
    Aalbers, J.
    Abe, K.
    Maouloud, S. Ahmed
    Althueser, L.
    Andrieu, B.
    Angelino, E.
    Angevaare, J. R.
    Martin, D. Anton
    Arneodo, F.
    Baudis, L.
    Baxter, A. L.
    Bazyk, M.
    Bellagamba, L.
    Biondi, R.
    Bismark, A.
    Brookes, E. J.
    Brown, A.
    Bruno, G.
    Budnik, R.
    Bui, T. K.
    Cardoso, J. M. R.
    Chavez, A. P. Cimental
    Colijn, A. P.
    Conrad, J.
    Cuenca-Garcia, J. J.
    D'Andrea, V.
    Garcia, L. C. Daniel
    Decowski, M. P.
    Di Donato, C.
    Di Gangi, P.
    Diglio, S.
    Eitel, K.
    Elykov, A.
    Ferella, A. D.
    Ferrari, C.
    Fischer, H.
    Flehmke, T.
    Flierman, M.
    Fulgione, W.
    Fuselli, C.
    Gaemers, P.
    Gaior, R.
    Galloway, M.
    Gao, F.
    Ghosh, S.
    Glade-Beucke, R.
    Grandi, L.
    Grigat, J.
    Guan, H.
    PHYSICAL REVIEW C, 2024, 110 (01)
  • [28] TIME RESOLVED STUDY OF THE UV CONTINUUM OF XENON
    JOWKO, A
    FORYS, M
    BARTKIEWICZ, E
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1990, 140 (02): : 421 - 424
  • [29] NEXT-CRAB-0: a high pressure gaseous xenon time projection chamber with a direct VUV camera based readout
    Byrnes, N. K.
    Parmaksiz, I
    Adams, C.
    Asaadi, J.
    Baeza-Rubio, J.
    Bailey, K.
    Church, E.
    Gonzalez-Diaz, D.
    Higley, A.
    Jones, B. J. P.
    Mistry, K.
    Moya, I. A.
    Nygren, D. R.
    Oyedele, P.
    Rogers, L.
    Stogsdill, K.
    Almazan, H.
    Alvarez, V.
    Aparicio, B.
    Aranburu, A. I.
    Arazi, L.
    Arnquist, I. J.
    Ayet, S.
    Azevedo, C. D. R.
    Ballester, F.
    del Barrio-Torregrosa, M.
    Bayo, A.
    Benlloch-Rodriguez, J. M.
    Borges, F. I. G. M.
    Bounasser, S.
    Carcel, S.
    Carrion, J. V.
    Cebrian, S.
    Cid, L.
    Conde, C. A. N.
    Contreras, T.
    Cossio, F. P.
    Dey, E.
    Diaz, G.
    Dickel, T.
    Elorza, M.
    Escada, J.
    Esteve, R.
    Fahs, A.
    Felkai, R.
    Fernandes, L. M. P.
    Ferrario, P.
    Ferreira, A. L.
    Foss, F. W.
    Freitas, E. D. C.
    JOURNAL OF INSTRUMENTATION, 2023, 18 (08)
  • [30] Scintillation Yield and Scintillation Time Dependence in Gaseous Argon with Different Purities
    Chen, Qinghao
    Cheng, Jianping
    Yue, Qian
    Du, Yingshuai
    Liu, Weirong
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,