Montmorillonite clay-modified disposable ink-jet-printed graphene electrode as a sensitive voltammetric sensor for the determination of cadmium(II) and lead(II)

被引:0
|
作者
Léopoldine S. Guenang
Liliane M. Dongmo
Sherman L. Z. Jiokeng
Arnaud T. Kamdem
Giscard Doungmo
Ignas K. Tonlé
Victor Costa Bassetto
Milica Jović
Andreas Lesch
Hubert Girault
机构
[1] University of Dschang,Electrochemistry and Chemistry of Materials, Department of Chemistry
[2] University of Buea,Inorganic Chemistry Laboratory, Department of Chemistry
[3] EPFL,Laboratoire d’Electrochimie Physique Et Analytique
[4] University of Freiburg,Freiburg Materials Research Center (FMF)
[5] Christian-Albrechts-Universität zu Kiel,Institute of Inorganic Chemistry
[6] University of Bologna,Department of Industrial Chemistry “Toso Montanari”
来源
SN Applied Sciences | 2020年 / 2卷
关键词
Disposable ink-jet-printed graphene electrode; Montmorillonite; Cadmium(II); Lead(II); Bismuth(III); Square wave voltammetry;
D O I
暂无
中图分类号
学科分类号
摘要
This work describes a new sensitive sensor for the simultaneous electrochemical determination by square wave anodic stripping voltammetry of Cd2+ and Pb2+ ions in aqueous solution, based on a disposable ink-jet-printed graphene electrode (IPGE) modified by a thin film of montmorillonite (Mont) clay mineral. The clay was characterized by X-ray diffraction and scanning electron microscopy while the Mont–IPGE was analyzed by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry before its exploitation for sensing studies. EIS results revealed a low electron transfer rate on Mont–IPGE during the electro-oxidation of [Fe(CN)6]3−. The stripping response on both Cd2+ and Pb2+ analytes was improved by the in situ co-deposition with bismuth, added to the electrolyte solution, on the clay substrate. The proposed electrode showed great stability and good reproducibility. The key experimental parameters governing the stripping analysis of Cd2+ and Pb2+ were optimized. A linear relationship between peak currents and concentrations of the analytes was obtained in the range from 0.01 to 0.21 µM, leading to detection limits of 0.42 nM for Cd2+and 1.14 nM for Pb2+ ions, respectively (S/N = 3). The sensitivities to Cd2+ and Pb2+ ions were 921.8 A cm−2 M−1 and 1960.8 A cm−2 M−1, respectively. The Mont–IPGE sensor was used for the quantification of lead and cadmium in a mineral water.
引用
收藏
相关论文
共 50 条
  • [31] Fabrication of a Carbon Sphere-modified Electrode and Sensitive Determination of Cadmium(II)
    Xiangliang Nie
    Weibing Hu
    Analytical Sciences, 2010, 26 : 141 - 142
  • [32] Hg(II) immobilized MWCNT graphite electrode for the anodic stripping voltammetric determination of lead and cadmium
    Prabakar, S. J. Richard
    Sakthivel, C.
    Narayanan, S. Sriman
    TALANTA, 2011, 85 (01) : 290 - 297
  • [33] Electrochemical determination of lead and cadmium in rice by a disposable bismuth/electrochemically reduced graphene/ionic liquid composite modified screen-printed electrode
    Wang, Zhiqiang
    Wang, Hui
    Zhang, Zhihao
    Liu, Gang
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 199 : 7 - 14
  • [34] Simultaneous determination of cadmium (II), lead (II), copper (II) and mercury (II) by square-wave anodic stripping voltammetry at a montmorillonite-calcium modified carbon paste electrode
    Beltagi, Amr M.
    Ghoneim, Enass M.
    Ghoneim, Mohamed M.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2011, 91 (01) : 17 - 32
  • [35] Determination of Trace Cadmium and Lead in Water Based on Graphene-modified Platinum Electrode Sensor
    Tang Feng-Jie
    Zhang Feng
    Jin Qing-Hui
    Zhao Jian-Long
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (02) : 278 - 282
  • [36] Voltammetric determination of lead and cadmium in vegetables by graphene paste electrode modified with activated carbon from coconut husk
    Palisoc, Shirley T.
    Estioko, Leonard Cedrick D.
    Natividad, Michelle T.
    MATERIALS RESEARCH EXPRESS, 2018, 5 (08):
  • [37] Evaluation of a platinum electrode modified with hydroxyapatite in the lead(II) determination in a square wave voltammetric procedure
    El Mhammedi, M. A.
    Achak, M.
    Bakasse, M.
    ARABIAN JOURNAL OF CHEMISTRY, 2013, 6 (03) : 299 - 305
  • [38] Determination of groundwater mercury (II) content using a disposable gold modified screen printed carbon electrode
    Some, Issa Touridomon
    Sakira, Abdoul Karim
    Mertens, Dominique
    Ronkart, Sebastien N.
    Kauffmann, Jean-Michel
    TALANTA, 2016, 152 : 335 - 340
  • [39] Electrochemical determination of lead(II) using a montmorillonite calcium-modified carbon paste electrode
    Dong Sun
    Chidan Wan
    Gang Li
    Kangbing Wu
    Microchimica Acta, 2007, 158 : 255 - 260
  • [40] Electrochemical determination of lead(II) using a montmorillonite calcium-modified carbon paste electrode
    Sun, Dong
    Wan, Chidan
    Li, Gang
    Wu, Kangbing
    MICROCHIMICA ACTA, 2007, 158 (3-4) : 255 - 260