Doppler ultrasound in the measurement of pulse wave velocity: agreement with the Complior method

被引:0
|
作者
Jordi Calabia
Pere Torguet
Maria Garcia
Isabel Garcia
Nadia Martin
Bernat Guasch
Diana Faur
Martí Vallés
机构
[1] Hospital Universitari Dr. J.Trueta de Girona,Department of Nephrology
[2] University of Girona,School of Medicine
[3] IDIAP Jordi Gol,Research support Unit
来源
关键词
Transit Time; Doppler Ultrasound; Pulse Wave; Arterial Stiffness; Pulse Wave Velocity;
D O I
暂无
中图分类号
学科分类号
摘要
Aortic stiffness is an independent predictor factor for cardiovascular risk. Different methods for determining pulse wave velocity (PWV) are used, among which the most common are mechanical methods such as SphygmoCor or Complior, which require specific devices and are limited by technical difficulty in obtaining measurements. Doppler guided by 2D ultrasound is a good alternative to these methods. We studied 40 patients (29 male, aged 21 to 82 years) comparing the Complior method with Doppler. Agreement of both devices was high (R = 0.91, 0.84-0.95, 95% CI). The reproducibility analysis revealed no intra-nor interobserver differences. Based on these results, we conclude that Doppler ultrasound is a reliable and reproducible alternative to other established methods for the measurement of aortic PWV.
引用
收藏
相关论文
共 50 条
  • [21] NEW METHOD FOR NON-INVASIVE MEASUREMENT OF PULSE-WAVE VELOCITY IN AORTA USING DOPPLER SONOGRAPHY
    LOHR, E
    GOBBLER, T
    SEILER, I
    REIDEMEISTER, JC
    HERZ KREISLAUF, 1977, 9 (03): : 130 - 134
  • [22] Aortic Pulse Wave Velocity Measurement by Doppler Technique During Transesophageal Echocardiography Examination: A Feasible and Reproducible Method
    Plamondon, Isabelle
    Somma, Jacques
    Arsenault, Jean
    Saint-Pierre, Andre
    CIRCULATION, 2013, 128 (22)
  • [23] Regional analysis of the pulse wave velocity by Doppler
    Baguet, JP
    Kingwell, BA
    Dart, AL
    Shaw, J
    North, KE
    Jennings, GL
    JOURNAL OF HYPERTENSION, 2000, 18 : S81 - S81
  • [24] Noninvasive Method for Measuring Local Pulse Wave Velocity by Dual Pulse Wave Doppler: In Vitro and In Vivo Studies
    Wang, Zhen
    Yang, Yong
    Yuan, Li-jun
    Liu, Jie
    Duan, Yun-you
    Cao, Tie-sheng
    PLOS ONE, 2015, 10 (03):
  • [26] Pulse wave velocity as endpoint in large-scale intervention trial.: The Complior® study
    Asmar, R
    Topouchian, J
    Pannier, B
    Benetos, A
    Safar, M
    JOURNAL OF HYPERTENSION, 2001, 19 (04) : 813 - 818
  • [27] Effect of number of pulse repetition and noise on velocity profile measurement in ultrasonic pulse doppler method
    Murakawa, Hideki
    Oue, Akira
    Sugimoto, Katsumi
    Takenaka, Nobuyuki
    Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 2013, 79 (799): : 356 - 367
  • [28] Estimation of arterial pulse wave velocity with a new improved Tissue Doppler method
    Persson, A
    Eriksson, A
    Persson, HW
    Lindström, K
    PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 188 - 191
  • [29] Ultrasound imaging and Doppler flow velocity measurement
    Niederer, Peter F.
    TECHNOLOGY AND HEALTH CARE, 2010, 18 (03) : 245 - 265
  • [30] Velocity and turbulence measurements by ultrasound pulse Doppler velocimetry
    Jaafar, W.
    Fischer, S.
    Bekkour, K.
    MEASUREMENT, 2009, 42 (02) : 175 - 182