Doppler ultrasound in the measurement of pulse wave velocity: agreement with the Complior method

被引:0
|
作者
Jordi Calabia
Pere Torguet
Maria Garcia
Isabel Garcia
Nadia Martin
Bernat Guasch
Diana Faur
Martí Vallés
机构
[1] Hospital Universitari Dr. J.Trueta de Girona,Department of Nephrology
[2] University of Girona,School of Medicine
[3] IDIAP Jordi Gol,Research support Unit
来源
关键词
Transit Time; Doppler Ultrasound; Pulse Wave; Arterial Stiffness; Pulse Wave Velocity;
D O I
暂无
中图分类号
学科分类号
摘要
Aortic stiffness is an independent predictor factor for cardiovascular risk. Different methods for determining pulse wave velocity (PWV) are used, among which the most common are mechanical methods such as SphygmoCor or Complior, which require specific devices and are limited by technical difficulty in obtaining measurements. Doppler guided by 2D ultrasound is a good alternative to these methods. We studied 40 patients (29 male, aged 21 to 82 years) comparing the Complior method with Doppler. Agreement of both devices was high (R = 0.91, 0.84-0.95, 95% CI). The reproducibility analysis revealed no intra-nor interobserver differences. Based on these results, we conclude that Doppler ultrasound is a reliable and reproducible alternative to other established methods for the measurement of aortic PWV.
引用
收藏
相关论文
共 50 条
  • [1] Doppler ultrasound in the measurement of pulse wave velocity: agreement with the Complior method
    Calabia, Jordi
    Torguet, Pere
    Garcia, Maria
    Garcia, Isabel
    Martin, Nadia
    Guasch, Bernat
    Faur, Diana
    Valles, Marti
    CARDIOVASCULAR ULTRASOUND, 2011, 9
  • [2] Measurement of pulse wave velocity using pulse wave Doppler ultrasound: Comparison with arterial tonometry
    Jiang, Benyu
    Liu, Baoming
    McNeill, Karen L.
    Chowienczyk, Philip J.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (03): : 509 - 512
  • [3] Comparison of the Complior and Sphygmocor systems for measuring pulse wave velocity
    Millasseau, S
    Patel, S
    Redwood, S
    Chowienczyk, P
    JOURNAL OF HYPERTENSION, 2003, 21 : S158 - S158
  • [4] Arterial pulse wave propagation velocity in healthy dogs by pulse wave Doppler ultrasound
    Rodrigo B. Nogueira
    Lucas A. Pereira
    Alice F. Basso
    Ingrid S. da Fonseca
    Lorena A. Alves
    Veterinary Research Communications, 2017, 41 : 33 - 40
  • [5] Arterial pulse wave propagation velocity in healthy dogs by pulse wave Doppler ultrasound
    Nogueira, Rodrigo B.
    Pereira, Lucas A.
    Basso, Alice F.
    da Fonseca, Ingrid S.
    Alves, Lorena A.
    VETERINARY RESEARCH COMMUNICATIONS, 2017, 41 (01) : 33 - 40
  • [6] Comparison of the Complior Analyse device with Sphygmocor and Complior SP for pulse wave velocity and central pressure assessment
    Stea, Francesco
    Bozec, Erwan
    Millasseau, Sandrine
    Khettab, Hakim
    Boutouyrie, Pierre
    Laurent, Stephane
    JOURNAL OF HYPERTENSION, 2014, 32 (04) : 873 - 880
  • [7] Reproducibility of aortic pulse wave velocity as assessed with the new Complior Analyse
    Pereira, Telmo
    Maldonado, Joao
    Andrade, Ivo
    Cardoso, Eva
    Laranjeiro, Mafalda
    Coutinho, Rita
    Conde, Jorge
    BLOOD PRESSURE MONITORING, 2014, 19 (03) : 170 - 175
  • [8] Measurement of Pulse Wave Velocity in Fetal Descending Aorta with Dual Doppler Method: a Preliminary Study
    Eiji Ryo
    Michiharu Seto
    Keita Yatsuki
    Masayoshi Morita
    Hideo Kamata
    SN Comprehensive Clinical Medicine, 2021, 3 (5) : 1133 - 1136
  • [9] Measurement of the propagation velocity of pulse wave generated by ultrasound in arteries
    Zhang, Xiaoming
    Greenleaf, James F.
    Advances in Bioengineering, 2005, 57 : 69 - 70