Erratum to: A new concept and a comprehensive evaluation of SYSMEX UF-1000i flow cytometer to identify culture-negative urine specimens in patients with UTI

被引:0
|
作者
T. Monsen
P. Ryden
机构
[1] Umeå University Hospital,Department of Clinical Microbiology
[2] and University of Umeå,Department of Mathematics and Mathematical Statistics
[3] Umeå University,Computational Life science Cluster (CLiC)
[4] Umeå University,undefined
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:1705 / 1705
相关论文
共 14 条
  • [1] A new concept and a comprehensive evaluation of SYSMEX UF-1000i  flow cytometer to identify culture-negative urine specimens in patients with UTI
    T. Monsen
    P. Ryden
    European Journal of Clinical Microbiology & Infectious Diseases, 2017, 36 : 1691 - 1703
  • [2] A new concept and a comprehensive evaluation of SYSMEX UF-1000i flow cytometer to identify culture-negative urine specimens in patients with UTI
    Monsen, T.
    Ryden, P.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2017, 36 (09) : 1691 - 1703
  • [3] Screening for Urinary Tract Infection with the Sysmex UF-1000i Urine Flow Cytometer
    Broeren, Maarten A. C.
    Bahceci, Semiha
    Vader, Huib L.
    Arents, Niek L. A.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (03) : 1025 - 1029
  • [4] Evaluation of the Sysmex UF-1000i flow cytometer for screening of urinary tract infection
    de Frutos-Serna, Monica
    Luz Asensio-Calle, Maria
    Maria Haro-Perez, Ana
    Maria Blazquez-de Castro, Ana
    Nieves Gutierrez-Zufiaurre, Maria
    Iglesias-Garcia, Jesus
    ENFERMEDADES INFECCIOSAS Y MICROBIOLOGIA CLINICA, 2014, 32 (03): : 147 - 151
  • [5] Comparison between urine culture profile and morphology classification using fluorescence parameters of the Sysmex UF-1000i urine flow cytometer
    Jimenez-Guerra, G.
    Heras-Canas, V.
    Valera-Arcas, M. D.
    Rodriguez-Granger, J.
    Navarro, J. M.
    Gutierrez-Fernandez, J.
    JOURNAL OF APPLIED MICROBIOLOGY, 2017, 122 (02) : 473 - 480
  • [6] Cutoff values for bacteria and leukocytes for urine flow cytometer Sysmex UF-1000i in urinary tract infections
    Manoni, Fabio
    Fornasiero, Lucia
    Ercolin, Mauro
    Tinello, Agostino
    Ferrian, Melissa
    Hoffer, Paolo
    Valverde, Sara
    Gessoni, Gianluca
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2009, 65 (02) : 103 - 107
  • [7] Urine particles analysis: Performance evaluation of Sysmex UF-1000i and comparison among urine flow cytometer, dipstick, and visual microscopic examination
    Jiang, Tang
    Chen, Peisong
    Ouyang, Juan
    Zhang, Shihong
    Cai, Dan
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2011, 71 (01): : 30 - 37
  • [9] Evaluation of the Sysmex UF-1000i® urine flow cytometer in the diagnostic work-up of suspected urinary tract infection in a Dutch general hospital
    van der Zwet, Wil C.
    Hessels, Jan
    Canbolat, Fatih
    Deckers, Martine M. L.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2010, 48 (12) : 1765 - 1771
  • [10] Evaluation of Sysmex UF-1000i® flow cytometer as a screening method for asymptomatic bacteriuria and detection of Group B Streptococcus in pregnancy
    Angulo Lopez, Itziar
    Urrutikoetxea-Gutierrez, Mikel
    Aragon-Diez, Julia
    Fraca Padilla, Mercedes
    de Tuesta Del Arco, Jose Luis Diaz
    REVISTA ESPANOLA DE QUIMIOTERAPIA, 2020, 33 (03) : 193 - 199